Amperis sl
Amperis is a company specialising in state-of-the-art instrumentation for the diagnosis and testing of electrical substations. The company is located in the northwest of Spain, in the Polígono Industrial das Gándaras in the city of Lugo. After completing the construction and since November 2017 the company is located in the new headquarters, located at 14 Barbeito María Street. The new Amperis headquarters has offices and a new, more modern warehouse, with more internal conveniences and more facilities for the exit and entry of goods, with the aim of always providing a better service to the customer.
- (+34) 982 20 99 20
- info@amperis.com
- Barbeito María 14
Lugo, 27003
Spain
-
Product
Oxygen Analyzer
Rapidox 2100
-
The Rapidox 2100 is a high-performance oxygen (O2) analyser fitted with a rugged long-life zirconia sensor on a remote cable, together with a type K thermocouple sensor; allowing direct in-process measurement of oxygen and temperature in the sample gas. The sensors provide fast and accurate analysis over the low ppm oxygen range in harsh environments up to 650°C.
-
Product
Powerline Analyzer
NEXUS 1252
-
From the Industrial Giants, Fortune 100 companies to municipal utilities, an energy management and power monitoring program is critical to their success. The Nexus® 1252, the most advanced monitoring product, provides the global picture of power quality and usage from any metered point within a distribution network, enabling users to make power-related decisions quickly and effectively.
-
Product
Transformer Winding Resistance Meters
TWA Standard Series
-
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
Product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
-
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
Product
SF6 Gas Detection Thermographic Camera
TC706
-
The TC706 displays and signals SF6 gas leaks, without the need to de-energize high-voltage equipment or stop operation. The portable camera also highly improves operator safety by detecting emissions at safe distances and helping to protect the environment by detecting the leakage of environmentally harmful gases into the atmosphere.
-
Product
SF6 Leak Detector
-
The Amperis SF6 leak detector uses an innovative infrared absorption detection cell that is extremely sensitive to SF6.
-
Product
Analyzers and Timers
CAT Advanced Series
-
Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:
-
Product
Telurometer
AMRU 120
-
Technical method with 3 or 4 poles, Technical method with the use of additional clamps, Measurement of the continuity of compensating and protective connections with self-neutralization function, Double clamp method without the need to place auxiliary electrodes, Soil resistivity in addition to
-
Product
Three-Phase Relay Test Equipment
AK-6
-
*5 automatic or manual test modules: DC test, AC test, distance test, harmonics and frequency protection*Phase, frequency and amplitude are continuously and independently adjustable.*All-in-one design: built-in Windows CE & rotary encoder & keyboard & 6.4" TFT LCD (RJ45/USB for updates and downloads)*High power: 3x450VA at 0...35A average voltage test
-
Product
Thermal Imaging Cameras
IRDL708 Series
-
The IRDL708 thermal imaging cameras are the new developed uncooled detector cameras, which have high resolution of 640x480 pixels, multi-rotary touch screen, normal and infrared image fusion, high brightness LED light, recording in H.264 format or normal format, images in JPEG format, light and sound alarm, voice and text annotations, network interface, built-in laser pointer, etc.
-
Product
Three-Phase Relay Test Equipment
AK-30
-
AC voltage source with 4 channels, current source and aux with 6 channels. DC source can be used simultaneously. Amplitude, frequency and phase angle can be adjusted respectively, independently and continuously; Control via PC via Ethernet RJ45 interface
-
Product
Short Circuit Loop Impedance Meter
AMZC-304
-
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
Product
Transformer Winding Resistance Meters
RMO TD Series
-
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
Product
Multifunction Meter for Electrical Installations
AMPI-530
-
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
Product
Transformer Winding Resistance Meters
RMO TT Series
-
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.















