Product
Partial Discharge Testing Equipment
AR700
-
PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.
-
Product
Transformer Turns Ratio Meter
TTRM 101
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Transformer Turns Ratio Meter
TTRM 102
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Surge Arrestor Testing Equipment
SA 30i
-
SA 30i, the Leakage Current Analyser from SCOPE is a State of the Art, On-line test system for Residual Life Assessment of Metal Oxide Surge Arresters. The instrument measures and directly displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current. It provides system harmonic compensation as per IEC 60099-5-B2. It provides Corrected Resistive Leakage Current after applying correction factors for change in system voltage & temperature.
-
Product
Primary Injection Kit
Prima Series
-
Prima Series is designed for Primary Current Injection Testing of Current Transformers, Protection Relays & Circuit Breakers during their Factory Test, Commissioning and Routine Testing.
-
Product
Partial Discharge Testing Equipment
PD-Analyser
-
This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.
-
Product
Pre- Locator
CFL PL3+
-
The new generation CFL PL3+ Cable Fault Pre-locator from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately up to 128 km.
-
Product
Winding Resistance Meter
TRM 25
-
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
Product
CT Polarity Tester
DIR CT
-
SCOPE proudly introduces Dir CT, a CT Polarity Tester specially designed to verify correctness of polarity of current transformers cores in live EHV switchyards. Polarity test is one of the most common yet crucial tests required to be done on current transformers by commissioning as well as maintenance engineers. Even though it is commonly conducted check, there was no all in one simple tool available for this measurement. DIR CT fills this void to perfection, it is expected to significantly reduce the time taken for polarity checks on numerous CT in sub-station, especially during commissioning of new sub-stations
-
Product
Contact Resistance Meter
CRM 100C
-
CRM 100C directly measures resistance values with DC current injection under live switchyard conditions.The CRM 100C is specially designed to reliably measure contact resistance of Circuit Breakers, Isolators, Bus Bar joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards. It can also be used for testing cables, graphite bars etc.
-
Product
SIM Filter
-
The CFL SIMF, Cable Fault Secondary Impulse Filter from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately.
-
Product
Pre- Locator
CFL PL2+
-
The new generation CFL PL2+ Cable Fault Prelocator from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately up to 50 km.