Physitemp Instruments
Physitemp Instruments Inc is an electrical/electronic manufacturing company.
- 800.452.8510
973.779.5577 - (973) 779-5954
- 189 Sargeant Avenue
Clifton, NJ 07013
United States of America
-
Product
Needle Microprobe
MT-26/6HT
-
Fast-response 26 gauge needle probe, (needle length is 6 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Thermalert Monitoring Thermometer
TH-5
-
The TH-5 is one of our most economical precision thermometers in the Physitemp product line. The TH-5 offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-5 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
Product
Ultra Fast Flexible Implantable Microprobe
IT-23
-
IT-23 Flexible Implantable Microprobe - For ultra fast measurements and for use on micro-size specimens. Time constant 0.005 seconds. Tissue Implantable with a 23 gauge needle (supplied). Fairly fragile. Sensor wires are twisted TFE Teflon™ insulated. Maximum Temperature 150°C. Isolated. Probe diameter .011", 3 foot lead.
-
Product
Needle Microprobe
MT-26/4HT
-
Fast-response 26 gauge needle probe, (needle length is 4 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Gauge Type T Thermocouple Wire
W-TW-20
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Flexible Implantable Microprobe
IT-14
-
IT-14 Flexible Implantable Microprobe - Implantable in semi-solids and tissue with 14 gauge needle (supplied). Also for immersion in various solutions. Totally sheathed in chemical resistant Teflon™. Quited rugged. Maximum Temperature 150°C . Isolated. Probe diameter .050" (14 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.3 seconds.
-
Product
Thermalert Clinical Monitoring Thermometer
TH-8/AOP
-
The TH-8/AOP is one of our most economical precision thermometers in the Physitemp product line. The TH-8 offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-8 has a temperature range 0f -10 to +60°C with 3 probe inputs. The TH-8 is also switchable from celsius to Fahrenheit. The TH-8 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
Product
General Purpose Probe
BT-1
-
BT-1 General Purpose Probe - Probably our best general purpose probe designed for temperature measurement of solids, liquids, gases and semi-solids. Welded stainless-stell shaft, plastic handle. Tip is .028'' diameter bent at right angle to probe to facilitate accurate surface measurements. Immersible. Maximum temperature 240°C, Time constant 0.15 Seconds. 5 foot lead. Not isolated.
-
Product
Needle Microprobe
MT-26/2HT
-
Fast-response 26 gauge needle probe, (needle length is 2 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Air And Gas Probe
GT-1
-
GT-1 Air and Gas Probe - 24'' #304 stainless steel shaft. Wooden Handle. For instant readings of temperature gradients in environmental chambers, freezer boxes, etc. Diameter is .3/16'' diameter. Immersible. Maximum temperature 200°C, Time constant Seconds. 5 foot lead. Not isolated.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Vibration Sensitivity Tester
Vibratron II
-
The Vibratron II provides a non-invasive means of measuring the sensitivity to vibration of large nerve fibers of a patient's fingers and toes. Reliable quantitative measurements are achieved with a test that takes only minutes to administer. A two-alternative forced choice procedure is used to determine the degree of sensitivity for comparison to normals.
-
Product
Thermalert Clinical Montoring Thermometer With Analog Output
TH-5/AOP
-
The TH-5?AOP is one of our most economical precision thermometers in the Physitemp product line. The TH-5/AOP offers the same high accuracy (0.1°C ±1 digit) and resolution as all our other thermometers, but with a narrow temperature range. The TH-5 is ideally suited for either a laboratory or hospital setting where continuous temperature readings within the physiological range are sufficient.
-
Product
Flexible Implantable Microprobe
IT-21
-
IT-121 Flexible Implantable Microprobe - Implantable in semi-solids and tissue with 21 gauge needle (supplied). Ideal for subcutaneous and cranial temperatures in small animals. Also for immersion in various solutions. Totally sheathed in chemical resistant Teflon™. Maximum Temperature 150°C . Isolated. Probe diameter .016" (21 gauge represents the needle gauge that the probe can be inserted through). Time constant 0.08 seconds.
-
Product
Gauge Type T Thermocouple Wire
W-TW-36
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.















