Product
Low Range Low Cost OEM Differential Pressure Transducer
P17
-
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
Product
USB-COM Data Logger
-
The USB-COM Utility is a free data logging andconfiguration program for use with the Validyneseries of USB or Serial pressure transducers.USB-COM Utility also comes in a premiumversion that allows up to eight signals to begraphed simultaneously while being recorded toa .csv file. The graph X and Y axis may bescaled to any values set by the user. A separatehistorical graph provides a complete visualrecord of the signals from the start of logging.
-
Product
Ruggedized Pressure Transducer
P24
-
The P24 Differential Pressure Transducer is the combination of a variable reluctance pressure transducer and a miniature carrier demodulator integrated into a single package to provide for operation from mobile dc power and deliver a standardized dc output suitable for recording or telemetry.
-
Product
Pressure Sensor Kit for Changing Ranges
DP15TL
-
The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.
-
Product
Wet-Wet Differential Pressure Sensor
DP303
-
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
Product
Pressure Sensor Interface
USB2251
-
The USB2251 Pressure Sensor Interface provides real-world data acquisition for your PC via the USB port. 8 calibrated variable reluctance pressure sensor inputs are accepted by the USB2251. No external signal conditioning is required.The USB2251 includes a connector panel for sensor cables, calibration constants for each sensor , configuration and data acquisition software. The USB2251 produces a floating-point value for all readings, directly in engineering units.The USB2251 can record pressure readings up to 5000 samples per second. Combined with the fast response of the Validyne VR pressure sensors, the USB2251 is ideal for transient pressure studies. The USB2251 is compatible with the following Validyne variable reluctance pressure sensors: AP10, DP103, DP10, DP45, DP15 DP360, DP215, and DP363. Each sensor is calibrated with the USB2251 at the factory and is ready to make measurements.
-
Product
Very Low Pressure Variable Reluctance Sensor
DP103
-
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.
-
Product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
-
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
Product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
-
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.
-
Product
Portable Digital Manometer
PS309
-
Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.
-
Product
Vehicle Pressure Acquisition System
VPAS
-
The Vehicle Pressure Acquisition System (VPAS) is designed to record and display up to 8 or 16 low pressure measurement points for the investigation of vehicle pressures within the passenger cabin, in HVAC ducting or with respect to the exterior of the vehicle. Validyne DP103 pressure sensors can be ordered with full scale ranges as low as 0.1 in H20 and up to 55 in H20.
-
Product
Test and Measurement Pressure Transducer
P895
-
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
Product
Pressure Transducers with CAN Bus Interface
P66
-
The Validyne model P66 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via CAN Bus provides remote zero and span adjustment as well as digital pressure readings in engineering units or pressure counts.
-
Product
High Line Pressure Transducer with Digital Interface
P368
-
The Validyne model P368 is a digital differential pressure transmitter designed for high line pressures and industrial pressure measurement applications. Full scale ranges of 8 psid to 10,000 psid are available. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via RS485, USB or CanBus provides remote zero and span adjustment as well as digital pressure readings in engineering units.
-
Product
ReCalibration and Post Calibration Software
SI58
-
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.