Product
Capacitance Bridge
1620
-
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
Product
Micro-Ohmmeter Calibration Kit
LOM-530
-
The LOM-530 is convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of micro-ohmmeters. The standard resistance values are those used by the LOM-510A Microohmmeter/Milliohmmeter.
-
Product
Capacitance Standard
SCA Series
-
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
Product
High Frequency Standard Capacitor
GenRad 1403 Series
-
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
Product
Decade Capacitor
GenRad 1423-A
-
The GenRad 1423 decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference Standard Capacitors.Used with a limit bridge, such as the GR 1689 Digibridge, the 1423 facilities fast and accurate production-line measurements of arbitrary capacitancevalues with minimum setup time.
-
Product
Megohmmeter
1864-9700
-
The GenRad 1864 Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10VDC to 109VDC in 1-volt steps and to 1090VDC in 10 volt steps. Thus the GenRad 1864 can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. An additional range on the 1864 Megohmmeter permits measurements up to 200 T (2 x 1014)
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Programmable Capacitance Decade Box
PCS Series
-
A broad range of laboratory grade programmable capacitance decade boxes for applications requiring a programmable impedance unit controlled manually and by a computer via an IEEE-488, RS-232 interface.
-
Product
Decade Resistor
1433 Series
-
The 1433 Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy, stability, and low zero resistance are important. They are convenient resistance standards for checking the accuracy of resistance-measuring devices and are used as components in dc and audio-frequency applications.
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
Product
Decade Capacitor
1419 Series
-
GenRad 1419-A and GenRad 1419-B (Polystyrene) Owing to its very low dielectric absorption, the GenRad 1419A 3 Decade 1000 pF/step & 1419B 4 Decade 100 pF/step Polystyrene Decade Capacitors are particularly useful in research and development work on computer and integrator circuits and on low-level amplifiers. Its constancy of capacitance and dissipation factor as a function of frequency also makes it extremely useful in measuring circuits and as a component in filters and tuned circuits. High insulation resistance and low dielectric absorption make it the 1419 Decade Capacitor a nearly ideal capacitor for dc work.
-
Product
Programmable Inductance Decade Box
PLS Series
-
The PLS Series is a broad line of high precision programmable decade inductors. They provide straight inductance in a wide selection of ranges, tolerances andratings. IET Labs also supplies custom combination substituters for capacitance and resistance as well as sources for voltage and current.
-
Product
Benchtop LCR Meter
1692
-
The GenRad 1692 LCR Meter is a sophisticated, microprocessor-controlled tester that brings new levels of flexibility, simplicity and accuracy to RLC measurement. It's testing automation at its best with a range of programmable test frequencies and test voltages, as well as automatic limit comparison, automatic parameter selection, remote programmability, automatic binning and automatic zeroing. The display facilitates visual acquisition of test data and eliminates costly guesswork and errors. The 1692 LCR Meter provides a powerful combination of features designed to maximize productivity in production testing applications.
-
Product
Standard Capacitor
1409 Series
-
The elements used in 1409 Standard Capacitors are selected for low dissipation factor and are stabilized by heat cycling. They are housed in cast aluminum cases, along with silica gel which provides continuous desiccation. These cases are sealed with high-temperature wax. A well is provided in the wall of the case for insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case, and removable banana plugs on the bottom, for convenient parallel connection without error
-
Product
Precision Impedance Meter
1689
-
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.