Contaminant
-
Product
Sample Pretreatment For Optical Emission Spectrometry
-
Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.
-
Product
Molecular Spectroscopy
-
Molecular Spectroscopy requires a range of technologies, including pick-and-place automation for moving sample tubes, sample injection automation to reduce sample contamination and consumption of rinse-solutions, and basic autosamplers for delivering samples to the analyzer. A variety of pumping technologies are also used to manage the delivery of samples and rinse solutions as needed.
-
Product
PXI Single 16 Channel Switch Simulator
40-485-221
Switch Module
Designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
Product
Humidity Sensors
-
digital humidity sensor with integrated temperature sensor that provides excellent measurement accuracy at very low power. The device measures humidity based on a novel capacitive sensor. The humidity and temperature sensors are factory calibrated. The innovative WLCSP (Wafer Level Chip Scale Package) simplifies board design with the use of an ultra-compact package. The sensing element of the HDC1008 is placed on the bottom part of the device, which makes the HDC1008 more robust against dirt, dust, and other environmental contaminants. The HDC1008 is functional within the full 40C to +125C temperature range.
-
Product
Laser Process Analyzers
LGR-ICOS Series
-
LGR-ICOS laser process analyzers accurately measure gas concentrations with extraordinarily high sensitivity, fast response and over a wide dynamic range in both simple and complex mixtures. They are ideal for contaminant monitoring in HyCO (syngas), fuel gas, petrochemicals, and semiconductor fabrication facilities.




