Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
BF-Series Standard Models
-
The E-DRIV® BF-Series standard models feature an adjustable RPM setting on the tool and a selectable Soft Start mode. Engineered for high volume manufacturing applications the brushless motor design ensures durability and reduces the standard maintenance costs associated with brush type electric screwdrivers. The BF power tool is ESD certified, ensuring less than 1 Ohm at the bit tip. ESD management assures product quality, cost savings and a reduction in overall ESD failures.
-
Product
Frequency to Voltage Converters
-
Encore Electronics offers a complete line of frequency to voltage converters ranging from the economically priced and compact DIN rail mounted Model FL228 to the rack mounted Model 225. For applications requiring performance between these two models, we now offer our FL236 DIN-rail packaged Digital Frequency/Voltage converter, featuring fast response time, low power and compact footprint.
-
Product
UV SHG Cavity Compact Frequency Quadrupling Module
SolsTiS ECD-X-Q
-
SolsTiS ECD-X Q extends the range of the SolsTiS platform into the deep UV providing unrivalled power and tuning. SolsTiS ECD-X-Q is used in combination with the ECD X doubling cavity (wavelength ranges between 210–250 nm) or the EMM mixing module (wavelength ranges between 250–300 nm).
-
Product
Standard 1.18 (33.30) - 3.25 (97.00) Battery Probe
BIP-1
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 16Test Center (mil): 150Test Center (mm): 3.81Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 250,000Overall Length (mil): 323Overall Length (mm): 8.20
-
Product
Standard Flexiforce Sensors for Force Measurement
FlexiForce
-
FlexiForce force sensors are ultra-thin and flexible printed circuits, which can be easily integrated into force measurement applications. These sensors are available for purchase in our online store.
-
Product
2GHz programmable frequency dividerValon
3010a
-
The Valon 3010a accepts a wide range of input frequencies and provides three independent, user-selectable, divided outputs. The 3010a is useful for extending the low-frequency range of any signal source down to 5MHz as a 50Ω output or down to 0Hz as a TTL output.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1R1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-4
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HL-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Nanolattice Standards for Analytical Instruments
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of Electron and Atomic Force Microscopes (AFM). Make the grade, with the highest quality pitch standard of its kind available.
-
Product
Standard 4.10 (116.00) - 6.50 (184.00) Switch Probe
MSP-3C
Switch Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 140Full Travel (mm): 3.56Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 2,140Overall Length (mm): 54.40Switch Point (mil): 30Switch Point (mm): 0.76
-
Product
Standard High Speed A/D Converters
-
Analog Devices high speed A/D converters (ADCs) offer the best performance and highest sampling speed in the market. The product offerings include low IF A/D converters (20 MSPS to 125 MSPS), high IF a/d converters (125 MSPS to 1.3 GSPS), and wideband ADCs (>1 GSPS). The high speed a/d converter portfolio offers cost and performance optimized solutions for various applications such as communications infrastructure, electronic test and measurement, and aerospace and defense.
-
Product
CPCI-S.0 Standard Compliant Peripheral Carrier Board
MIC-3810
-
The carrier board provides a PCIe x16 connector for standard PCIe x8, PCIe x4, PCIe x1 PCIExpress® cards supporting PCIe Gen3 speeds. The carrier board can accommodate cards with maximum dimensions of 176 x 68.9 mm (6.9" x 2.7" inches).
-
Product
Vector Network Analyzer (VNA) Simulator – Standard
S94050B
Vector Network Analyzer
S94050B puts flexible S-parameter analysis into your own computer. Dive deeper into measurements captured on a network analyzer or develop and optimize test programs before deploying them onto an instrument.
-
Product
Frequency Converter Test Solution Up To 50 GHz
N5245BP
-
The N5245BP provides the N5245B 50 GHz PNA-X network analyzer, application software and accessories for frequency converter test up to 50 GHz. This bundle product
-
Product
Frequency Dividers
-
Holzworth Instrumentation, Inc.
The HX4210 was designed as a reference output translator for Holzworth's early RF Synthesizer designs. The key design requirement was to maintain the low phase noise /jitter characteristics the 100MHz calibrated reference output signal so that it could be utilized as a 10MHz laboratory reference standard.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3C
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4C
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2TB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Variable Frequency Modules
9554-( )
-
Utilizing the high voltage power source in the Model 9354-1 Universal Transient Generator, four individual modules can be connected to provide tuning of damped sine waves from 10 KHz to 50 MHz. A fifth module is available which, when used in conjunction with the Model 9354-1, provides 20% frequency steps from 30 MHz to 100 MHz
-
Product
Standard Test Chambers
-
HIACC Engineering & Services Pvt. Ltd.
Designed for testing the durability, safety, and performance of products under various conditions.
-
Product
Standard Tests
-
The following list contains only the most important standards and does not claim to be complete.EN 60204-1 Electrical equipment of machinesEN 60335-1 Electrical appliances for household and similar useEN 50106 Sampling test, routine tests (in conjunction with EN 60335-1)EN 60598-1 LuminariesEN 60601-1 Medical electrical equipmentEN 60730-1 Automatic electrical controlsEN 61010-1 Measuring, control and laboratory equipmentEN 61439-1 Switch cabinet and switchgearEN 62368-1 Equipment for audio/video, information and communication technologyEN 62841-1 Hand-held electric toolsEN 50191 Erection and operation of stationary and non-stationary electrical test equipmentLVDLow V oltage D irective _
-
Product
Frequency & Pulse Distribution
-
Timetech frequency distribution amplifiers and pulse distribution units.
-
Product
Universal Frequency Counter LXI, GPIB
53220A
-
For fast and accurate frequency and time-interval measurements, you need reliable devices in research and development. The Keysight 53220 universal frequency counter meets the requirements for this with its high accuracy, bandwidth and speed. Depending on the application and budget, choose one of the three available models. The connection to the PC is via USB, Ethernet/LXI or via GPIB.
-
Product
Certified Leak Standards
-
Cincinnati Test Systems provides certified, high-performance air flow leak standards and tracer gas leak standards.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40A
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard Tap Position Indicator
-
NMC,s Tap Position Indicator is a Microprocessor based specially designed instrument used to indicate the Tap Position of the Power Transformer with On Load Tap Changer.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations





























