Frequency Standards
Devices that produce a known frequency.
See Also: Hydrogen Frequency Standards, Rubidium Standards, GPS Clocks
-
Product
Frequency Counter with Rubidium Timebase
SR625
-
Stanford Research Systems, Inc.
The SR625 Frequency Counter is a NIST traceable frequency counting standard for calibarating base stations, transmitters and many other types of communication systems.
-
Product
Frequency Dividers
-
Precision Test Systems manufacturers' various divider boards as options to its range and frequency standards and distribution amplifiers.
-
Product
Horn Antennas
-
Broadband antennas, compared to half wave dipoles, reduce test time because the technician did not have to stop the test to adjust the dipole antenna for each frequency. Most compliance standards now require the use of such antennas. The latest version of Mil-Std 461E states the used of broadband double ridge guide horn antenna as the antenna of choice for frequencies above 200 MHz.
-
Product
Rubidium Oscillators
-
Our range of atomic / rubidium disciplined time and frequency standards in a variety of enclosures and sizes to suit all appliations. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
Product
Frequency Reference
-
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
Product
Cold-Atom Frequency Standard
-
Rack-mount microwave atomic clock using laser-cooled 87Rb atoms. Production unit target specifications: Allan deviation 2×10-12 @ 1 s, 2×10-14 @ 104 s; flicker floor 1×10-14; absolute accuracy < 1×10-13.
-
Product
Computer Controlled, Solid-State RF Switch Matrices
-
PMI offers a full product line of RF Switch Matrices that operate over the 20MHz to 40GHz frequency range. Three standard models are offered that cover this frequency range, namely 20MHz to 3.0GHz, 2.0GHz to 18.0GHz, and 18.0GHz to 40.0GHz. Any of the three models can be supplied as either a 4 X 4, 8 X 8, 16 X 16, or 32 X 32 non-blocking matrix.
-
Product
Frequency Calibrator
VCH-313
-
The frequency calibrator VCH-313 is designed to determine the frequency error and calibrate frequency standards of various types based on the signals of the NSC SNS GLONASS/GPS .
-
Product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
-
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.
-
Product
Climate Chamber
VCH-A18
-
The climatic chamber is designed to maintain a stable temperature of frequency and time standards and other high-precision electronic devices.
-
Product
Frequency Converter
A6
-
The Quartzlock model A6 frequency converter precisely changes either 5 or 10MHz sine wave signals to a number of other frequencies from 1Hz and 1pps upwards to other standard frequencies.
-
Product
Calibration Executive Software
CalEasy Series
-
CalEasy is a full-featured, Calibration Executive software package that supports the verification and calibration of Marvin Test Solutions instruments. The software is intended for use by users that prefer to perform in-house calibration and verification for their Marvin Test Solutions instruments. By calibrating or verifying the instrument in-house, the time and cost associated with returning an instrument to Marvin Test Solutions for calibration service can be eliminated or reduced. CalEasy is also used internally by Marvin Test Solutions production to perform initial calibration and to recalibrate the instrument when received for service. This ensures that user and factory based calibration performance is similar. Depending on the specific instrument, standards instrumentation supported for calibration / verification includes a DMM, and a frequency standards module. Some modules require the use of matrix switch card.
-
Product
Military Timing Solutions
-
Brandywine is AS9100C certified and supports the environmental testing and specific interface standards needed for simple integration within military hardware. Brandywine offers many standard options for our military timing products including cesium frequency standards for international applications as well as the option to customize each product to fit your specific timing needs.
-
Product
Frequency Standard Products
-
The ES-110 generates a stable source of 10 MHz using GPS (Global Positioning System) satellites as a reference. If frequency distribution is needed, we offer the ES-210, a Quad 1x6 1/5/10 MHz Distribution Amplifier. The ES-210 provides four independent 1x6 Frequency DAs in a single rack-mount enclosure. The ES-410 is a four output version of the ES-110. The ES-410 was introduced and won Radio Magazine's Best of Show Award at the 2016 NAB Show.
-
Product
Varactor Tuned Gunn Oscillators
-
Varactor tuned Gunn oscillators utilize high performance GaAs Gunn diodes and various cavity configurations to deliver moderate output power with low AM/FM noise and harmonic emissions. The oscillators are specially designed for a broader tuning bandwidth and an electrical tuning capability. The standard offering covers the frequency range of 8.2 to 110 GHz and features a self-locking set screw for fine frequency setting. While standard models offer a waveguide interface, a coaxial interface is also available. The performance of the oscillator can be further enhanced by adding an isolator, Gunn oscillator modulator/regulator, and temperature heater.
-
Product
Low G Sensitive Oscillators
-
Precision Test Systems is increasingly becoming a world leader in ultra-low phase noise (ULN) crystal and rubidium oscillators. We manufacture the CFS10B crystal frequency standard and the RFS10E and RFS10F rubidium frequency standards. All these models can also be locked to the global satellite service operated by the USA (GPS), Russian (GLOSNASS) and Europe (Galileo). We also have a complete range of distribution amplifiers to compliment these frequency standards.
-
Product
High Frequency Standard Capacitor
GenRad 1403 Series
-
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
Product
Ultra Low Noise, Rubidium Frequency Standard.
A10-M
-
Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.
-
Product
Distribution Amplifiers
-
The Quartzlock range of distribution amplifiers are intended for use when multiple outputs from a single frequency standard/generator are required. This may be encountered in engineering labs, national standards labs, research and development, calibration labs and production. This is vital for the distribution of signals from other precision frequency standards like Hydrogen Masers, Cesium oscillators. For a technical discussion about distribution amplifiers go here or select a product range below.
-
Product
Disciplined Frequency Standards
2960AR and 2965AR
-
The 2960AR has a rubidium timebase and provides two 10MHz and one 5MHz sine wave outputs. The 2965AR has a rubidium timebase and provides one 10MHz, one 5MHz and one signal generator output. The signal generator output uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50MHz via an RS232 serial interface. Both models can be disciplined by a 1pps input signal and provide a 1pps output. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
Product
Scalar Feed Horn Antennas
-
Scalar feed horns are offered as both standard and custom build models with either a circular or rectangular waveguide interface. While scalar feed horns with a rectangular waveguide interface can only support linear polarization, models with a circular waveguide interface can support various polarization types including horizontal, vertical, left-handed circular, and right-handed circular polarization for broader applications. The standard models operate across the full waveguide band and offer 17 dBi nominal gain, 25 degrees half power beamwidth and a -28 dB side lobe level at center frequency. The below standard offering covers the frequency range of 8.5 to 140 GHz. However, other frequencies or gain values are also available.
-
Product
Rubidium/GPS Frequency Standard
PXIe-3352
-
The Astronics Test Systems PXIe-3352 frequency standard module sets a new standard for high density functionality in a PXI module by combining a Rubidium oscillator with a GPS receiver into a single, compact instrument.
-
Product
Hydrogen Frequency & Time Standard
CH1-1033
-
The hydrogen frequency and time standard Ch1-1033 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes. Main areas of application: – public service of time and frequency; – ground control complexes of radio navigation systems; – radio interferometry with extra long base.
-
Product
Ultra Low Noise Disciplined Frequency 4220a Standard with Rubidium and OCXO Clean-Up Oscillator
-
Precise Time and Frequency, Inc.
The ptf 4220A is an Ultra Low Noise Disciplined Frequency Standard with rubidium and OCXO clean-up oscillator.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
Probe Antennas
-
Probe antennas are offered as both standard and custom models with a rectangular waveguide interface. Probe antennas can only support linear polarization. These antennas are often used to measure the gain of other antennas by comparing the signal levels of the probe antenna and antenna under testing. The standard models operate across the full waveguide band and offer 6.5 dB nominal gain and 115 and 60 degrees half power beamwidth at center frequency. The below standard offering covers the frequency range of 8.2 to 170 GHz.
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Vector Network Analyzer
R42XXE
-
The R42XXE Vector Network Analyzers are designed for measuring of S-parameters, VSWR and impedance of waveguide networks in the full frequency ranges of standard waveguides between 33 and 170 GHz. Frequency accuracy is ±0.2%. The measurement range of reflection factor modulus is from 0 to 1. The measurement range of reflection factor phase is from 0 to ±180° for 0.1< |Гx|<1 with accuracy ±7.5 o in 18-75 GHz frequency range and ±9.6° in 75-170 GHz frequency range. The measurement range of transmission factor phase is from 0 to ±180 o with accuracy ±(5+0.1 |Ax|) o for Ax >-50 dB in frequency range to 75 GHz, for Ax >-30 dB - to 170 GHz. Data can be displayed in the rectangular, Smith or polar diagrams. VNA requires Personal Computer with USB interface.
-
Product
Digital-Phase-Lock-Loop
-
The Quartzlock A6-CPS is a board level product designed for synchronising two stable oscillators. A typical example is the locking of a low phase noise OCXO to a rubidium frequency standard. The product uses a digital implementation of a standard phase lock loop.
-
Product
Multi-Channel Phase Comparator
VCH-315M
-
Multi-channel phase comparator VCH-315M, together with a computer and special software, is designed for simultaneous measurement of frequency instability characteristics (RMS, RMS) of a group of sinusoidal signals of standard frequencies 5; ten; 100 MHz.
-
Product
Hydrogen Frequency & Time Standard
CH1-1007
-
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.





























