Differential Probes
Measure signals that are not ground referenced.
-
Product
Low & High Voltage Differential Probes
T3
-
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
Product
High Voltage Differential Probes
DP Series
-
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
Product
Differential Probes (8-30 GHz)
-
The DH series of 8 to 30 GHz active differential probes provides high input dynamic range, large offset capability, low loading and excellent signal fidelity with a range of connection options.
-
Product
60 V Common Mode Differential Probes
-
The 60 V Common Mode Differential Probes are the ideal probes for lower voltage GaN power conversion measurement with the highest accuracy, best CMRR, and lowest noise.
-
Product
Differential Probes < 1.5GHz
-
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point
-
Product
Differential Pressure Probes
PP473-S…
-
Differential pressure probes complete with SICRAM module to measure pressure in the range 10, …, 2000 mbar.
-
Product
Y Lead Adapter for ZD Differential Probes Qty 1
PACC-ZD001
-
Y lead Adapter for ZD differential probes Qty 1
-
Product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
Differential Probe
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
Product
30 GHz differential probe with ProAxial interface
DH30-PX
Differential Probe
30 GHz differential probe with ProAxial interface.
-
Product
Optically Isolated Measurement System
IsoVu
-
IsoVu offers complete galvanic isolation and is the industry’s first measurement solution capable of accurately resolving high bandwidth, low voltage differential signals in the presence of large common mode voltages. The stand out feature of IsoVu™ is its best in class common mode rejection across the entire bandwidth. Accurate differential measurements rely on a measurement system’s bandwidth, rise time, common mode voltage, common mode rejection capability, and the ability to connect to smaller test points to characterize devices that are shrinking in size and increasing in performance. Despite these requirements, advancements in test and measurement for power testing, EMI testing, ESD testing, and remote measurement capability have been minimal at best and have not kept pace with changing requirements. While differential voltage probes have had modest performance gains in regard to bandwidth, these probes have failed to make any substantial improvements in regard to common mode rejection, and connectivity. IsoVu is a leap forward in technology and is the only solution with the required combination of high bandwidth, high common mode voltage, and high common mode rejection to enable these differential measurements.
-
Product
Digital Oscilloscope
DS6000
-
The 6000 Series Digital Oscilloscopes have 1 GHz of Bandwidth. Detecting high speed signals and device characteristics including ESD, digital video, and differential signals (using an differential probe accessory) is now easier than ever with our most advanced digital oscilloscope platform.
-
Product
DH Series PT Browser Tip, 16 GHz BW, 3.5 Vpp Range
DH-PT
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Differential Probe
-
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
Product
6 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip
D620-A-PL
Differential Probe
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3605A
Differential Probe
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
InfiniiMax Differential/Single-ended Connectivity Kit
E2669B
-
Includes a differential browser, four solder-in differential probe heads, and two socketed differential probe heads.
-
Product
Replacement Hook Clips for High Voltage Differential Probe
PK-HVA-03
-
Replacement Hook Clips for High Voltage Differential Probe
-
Product
DH Series Tip - CrossSync PHY PCIe5 CEM x16
DH-CSPHY-PCIE5-CEMX16
-
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Acute High Voltage Differential Probe, 20x/200x, 100MHz, 1400V
ADP2100
-
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
Product
Active Differential Probe
DF-600
-
The DF-600 Differential Active Probe is a high input impedance and low input capacitance probe. It also supports extremely high frequency bandwidth, and high voltage input. It is designed using three OP amps, namely two FET buffer OP amps and a low offset OP amp. Therefore, even with long-term operations, the measured voltage will not drift. The voltage offset always approach 0 volts. (USB power supply should be 5V ±2%). The following diagram shows the circuit of DF-600.
-
Product
Replacement Pincer Clips for High Voltage Differential Probe
PK-HVA-02
-
Replacement Pincer Clips for High Voltage Differential Probe
-
Product
Integrated Balun Probes
-
This is an example of a 900 MHz Integrated Balun Probe. It incorporates a 50 ohm unbalanced to 200 ohm balanced differential transformer. The probe can be built with or without a center tapped ground needle and may also incorporate DC bias through the differential pair or via separate needle contacts.
-
Product
T3 Low & High Voltage Differential Probes
T3 Series
-
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
13 GHz Differential Probe with ProLink Interface
DH13-PL
Differential Probe
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
Product
Differential Probe
DP-16VF
-
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω
-
Product
Digital Oscilloscope
DS6000 Series
-
The 6000 Series Digital Oscilloscopes have 1 GHz of Bandwidth. Detecting high speed signals and device characteristics including ESD, digital video, and differential signals (using an differential probe accessory) is now easier than ever with our most advanced digital oscilloscope platform.
-
Product
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A
Differential Probe
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
Low Voltage Differential Oscilloscope Probes
-
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!





























