Probing
See Also: Probers, Probing Stations, Nano Probes
-
Product
Wafer Probers
-
Devices to align probes to test the electrical properties of IC chips or TEGs (Test Element Groups) formed on wafers. The vast options available will meet various needs, from research to mass production.
-
Product
Infiniium V-Series Oscilloscope: 16 GHz, 4 Analog Channels
DSAV164A
Oscilloscope
16 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.32 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
Flying Probe Tester
FA1817
-
Flying Probe Tester FA1817, an automatic testing system designed to inspect printed wiring on bare boards. The FA1817’s features and capabilities make it ideal for use in inspecting high-density printed wiring boards. With support for a broad range of test types, from low-resistance measurement to high-insulation-resistance measurement, the system reliably detects the latent defects that trouble end-users.
-
Product
4 Channels DC Power Data Acquisition Device
NuDC-4U
-
NuDC-4U is an innovative product that provides better solution for power probing. Common DC power statistics including voltage, ampere and even the watt can be read instantly via NuDC-4U. Moreover, up to 4 sets of individual powers can be monitored simultaneously and the LCD screen can also display the maximum and minimum value of the current power during the test.
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Stand-Alone Test Fixture
MA 2013/D/H
-
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: NoInterface signals max.: 1700Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 22,00 kg
-
Product
Tackiness Tester
TAC1000
-
For the measurement of tackiness (instantaneous adhesive strength) of various pastes and adhesive tapes, it is possible to quantitatively evaluate the data, which until now had large errors due to individual differences. First, press the measuring probe, which is controlled (approach speed, pressure force, pressure time, separation speed) against the sample, and measure the adhesive force in the process of separating. Measured data can be processed by a computer. With double temperature control (patented), the sample piece is preheated from the back side with a hot plate and the heated probe penetrates the measurement surface, making it possible to keep the set temperature and the temperature of the test surface to be evaluated constant. Since the pressurization time can be as short as 10msec, it is possible to measure the tackiness caused by momentary contact.
-
Product
High-Voltage Differential Probe, 25 MHz
N2791A
High Current Probe
Use the N2791A 25-MHz low-cost high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2791A differential probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 700 V of differential voltage and common mode voltage.
-
Product
K Thermocouple Surface Probe
TP777
-
Surface thermocouple Type "K" probe. °C max: 200. Response time: 3 s.
-
Product
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil
T3RC3000-HF
-
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil.
-
Product
Test Hook Probe
CX-S11
-
Shenzhen Chuangxin Instruments Co., Ltd.
Test Hook Probe Used on enclosures prior to accessibility testing. The test hook is ¨hooked〃 into vents and seams in the enclosure & then pulled with a force (usually 20N).
-
Product
Input Digital Temperature Transmitter
HR6100
-
HighReach Measuring & Controlling System Co.,Ltd
The HR6100 input-type integrated temperature transmitter uses an imported temperature sensor to transmit and output RS485 standard signals through a built-in microprocessor. The product adopts the sealing structure of the liquid level transmitter, the waterproof cable outlet, the 316L stainless steel casing, And the temperature probe to the front end, which is suitable for occasions with special requirements on the installation dimensions.
-
Product
DC Meters/Rail Meters:
-
Digital DC Resistive Voltmeter has a single range of 0 – 2kV. The unit consists of a meter probe, second probe, and connector cable. This unit is designed to measure DC voltage between the negative return rail and overhead positive cantenary conductor used on transit systems. The five position selector switch located on the face, controls OFF, ON, and Test. The OFF positions are for storage and transit. The ON position is for measurements from 0 to 1999 volts with one-volt resolution. The T position tests basic meter functions and the digital display.
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1A-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Rogowski AC Current Probe,30 MHz, 600 A
N7041A
High Current Probe
The Keysight N7041A Rogowski coil current probe measures AC currents up to 600 A, with bandwidth ranging from 12 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Automated Tester
-
With high labor costs in Europe and the US, and the surge in labor cost in Asia, automated test solutions are in demand. Automated systems also improve traceability and reduce operator mistakes.The combination of automation with high throughput test systems is perfect to extend the usage of Flying Probe Testers to mid size production/sample volumes.
-
Product
High 0.75 (21.00) - 8.00 (227.00) Long Travel Bead Probe
BPLT-25F-8
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Infiniium V-Series Oscilloscope: 33 GHz, 4 Analog Channels
DSOV334A
Oscilloscope
33 GHz analog bandwidth4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with low noise floor (2.09 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
Climomaster Anemometer
6501 Series
-
The Climomaster anemometer is a research grade handheld hot-wire anemometer that promises level 2% m.v. accuracy, making it the most accurate hot-wire airflow meter in the world. It offers a ton of flexibility and options including 8 different probes types. These probes are all interchangeable and can be used with a single main unit without any additional calibration.
-
Product
Needle Microprobe
MT-29/5HT
-
Fast-response 29 gauge needle probe, (needle length is 5 cm) for instant readings in tissue, semisolids, liquids. Also for very small specimens, powders and materials. Needle tip is sealed to ensure only stainless steel contacts specimen. Max. temp. 200°C. 5 ft. lead. Smallest microprobes give fastest reading. Short probes are easier to insert and last longer. Type #'s indicate needle gauge and needle length in cm.
-
Product
Water Cut Meter
-
The Drexelbrook Universal IV Series products feature full compensation for both temperature and density as well as multiple mounting options which includes insertion and spool piece probes.
-
Product
Ingun Spring Probes
-
MicroContact AG offers the assortment of test probes and test adapters from Ingun as a Swiss representative.
-
Product
OTDR
EXFO-100
-
Hangzhou Softel Optic Co., Ltd.
* Top user-friendliness: one-button testing, combined with EXFO’s proprietary FTTx software package (macrobend/fault finder, pass/fail indicators)*Multiple options, including power meter, visual fault locator (VFL), fiber inspection probe, printer and IP testing*Fault Finder mode, for quick identification/location of a fiber break*Complete connectivity flexibility: USB stick compatibility and USB cable data download via ActiveSync**Advanced TFT transflective color display, for assured legibility under direct sunlight or in other demanding outside conditions*Handheld, small, lightweight unit: 1 kg (2.2 lb)*Built-in ruggedness for outside-plant usage*Troubleshooting option, enabling in-service, out-of-band network testing *EXFO’s AXS-100 Access OTDR combines the industry’s leading OTDR technology with power meter functiona lities in one powerful handheld unit.Optimized for testing passive optical networks (PON) within FTTx architectures, it offers several wavelength configurations and a wide range of options, for first-class flexibility. Use it at the optical network terminal(ONT), drop terminal or fiber distribution hub (FDH) for FTTH distribution(F2) fiber characterization, troubleshooting and fault locating.
-
Product
High 2.84 (81.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-25T36-8
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
BTP-25 Bead Probes
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Portable Thickness Gauge
Magna-Mike 8600
-
The Magna-Mike® 8600 is a portable thickness gauge that uses a simple magnetic method to make reliable and repeatable measurements on nonferrous materials. Operation of the Magna-Mike is very simple. Measurements are made when its magnetic probe is held or scanned on one side of the test material and a small target ball (or disk or wire) is placed on the opposite side or dropped inside a container.
-
Product
Plug-In Temperature Transmitter
HR6200
-
HighReach Measuring & Controlling System Co.,Ltd
The HR6200 input-type integrated temperature transmitter uses an imported temperature sensor and output RS485 standard signals or 4 to 20 mA standard signals through a built-in microprocessor. The product uses a 316L stainless steel casing, and the temperature probe is placed at The front end, which can be customized according to the requirements of the user.
-
Product
1000 Amp High Accuracy Current Probe
HA1000
-
The HA1000 is our most accurate current probe. The HA1000 clamp-on current probe measures from 1 to 1000 amps AC.
-
Product
Wireless In-Circuit Test Fixtures
-
Higher density more complex circuit boards complicate testing requirements while smaller more tightly spaced test pads create a wiring challenge for the fixture fabricators, test engineers and maintenance personnel. Wireless fixtures solve the challenges associated with the nest of wires found in standard long wire fixtures. Wireless fixtures replace the “nest” of wires with copper traces on a multilayered printed circuit board called a Translator Board or T-Board®. Circuit Check’s wireless fixture technologies reduce test program debug and maintenance times while easing the ECO process. Thus allowing for the higher level of test performance, the ability to probe smaller denser targets and achieve ultra-high node counts.