Current Transformers
transfers accurately proportional levels of current to multiple circuits.
-
Product
Current Measurement
-
Measurements International Ltd.
No Stabilization Period, No Power Coefficient, No Temperature Coefficient, DC and AC Operation, 3000 A Max Current DC.
-
Product
Automatic Transformer Tester
SS3250 / SS3252 / SS3302
-
Automatic transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process, with high stability and high reliability. With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, transformer's turn ratio and turn number with more precise measurement.
-
Product
Current Tester
MIG1248
-
The MIG1248 is a current generator with wave shape 8/20. Maximum impulse current is up to 48kA supported by a 12kV impulse voltage making the MIg1248 ideal for testing large varistors. An intergrated test cabinet can accomodate test components up to 5cm cube.
-
Product
Transformer Preamplifier
SR554
-
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
Product
Transformer Turns Ratio Meter
TTRM 101
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Current Probe
-
Beijing GFUVE Electronics Co.,Ltd.
Used to measure control currents for relays in electronic circuits and in evaluation testing of capacitors' current characteristics.
-
Product
Transformer Polarity Tester
PMT20030
-
Power Measurement Technologies Inc.
A hand held instrument for polarity identification of current, voltage and power transformers with an operable ratio range from 1:1 to greater than 5000:1.
-
Product
Transformer Turn Ratio Meter
-
A specialized, highly accurate diagnostic instrument used to measure the ratio of primary to secondary winding turns in transformers.
-
Product
Power Transformer
-
We are amongst the leading names in the industry, offering wide range of Power Transformer that are technically advanced in nature and have high strength. Our entire product line is dimensionally accurate in nature and requires low maintenance cost. They are thermostatically balanced in nature AND are easy to install.
-
Product
DGA Monitor for Transformers
OPT100 Optimus™
-
The Vaisala Optimus OPT100 DGA (Dissolved Gas Analysis) Monitor for Transformers gives you out of the box performance, completely eliminates false alarms, and offers the best long-term stable measurements of any device on the market – all with no maintenance. Spectral scanning provides selective gas measurement.
-
Product
Transformer Turns Ratio Meter
TTRM 102
-
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
Product
Transformer Winding Resistance Meters
TWA Standard Series
-
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
Product
Loss Measuring System for Transformers
LiMOS
-
HIGHVOLT Prüftechnik Dresden GmbH
The transformer loss measuring system LiMOS is designed for highly accurate measurement of losses and other parameters required in the framework of routine and type testing of power transformers. The combined voltage/current sensors and the digital signal processing enable a very compact design with only one HV device per phase with smallest volume and footprint. The digitized and preprocessed signals are transmitted via fiber optic cable to the receiver unit (LiMO-MCSU).
-
Product
Current Probe
LFR
-
Power Electronic Measurments Ltd
The LFR is ideal for power quality applications. It has a small, predictable phase error, for power measurements at 45/65Hz. The wide bandwidth allows accurate measurement up to and even above the 400th harmonic.
-
Product
Brute High Current Probe
P4301-2R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Eddy Current Sensor
eddyNCDT 3001
-
The eddyNCDT 3001 is a new, efficient eddy current sensor whose compact dimensions have to date only been reserved for inductive sensors and proximity sensors. The temperature-compensated design provides high stability even in fluctuating ambient temperatures. The eddyNCDT 3001 comes with integrated electronics, offering an outstanding price/performance ratio and easy operation. The eddyNCDT 3001 eddy current sensor is ideally suited to OEM integration and machine building applications. The sensor is factory-calibrated for ferromagnetic and non-ferromagnetic materials, which eliminates the need for field calibration of the sensor. The eddyNCDT 3001 is available with connector or with integrated cable. A robust design combined with the eddy current measuring principle enables measurements in harsh industrial environments (oil, pressure, dirt). In addition, the eddyNCDT 3001 is suitable for offshore/marine applications (salt water).
-
Product
Transformer Capacity Tester
-
Weshine Electric Manufacturing Co., Ltd
In many industries, including health care, manufacturing, electrical contracting, higher education and corrections, reliable, high-quality transformers are essential for keeping operations running efficiently. Large facilities and industrial processes require substantial amounts of power, and they need dependable transformers to convert the energy coming from the power plant into a form they can use for their equipment and building utilities.
-
Product
Current Probe
PA-699
-
*High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability
-
Product
Loading Transformer
CL-6
-
This readily portable Knopp Loading Transformer weighs only 60 pounds and measures 12″ long, 9″ wide, and 10″ high. Its sturdy enclosure provides protection and adequate ventilation. Two convenient carrying handles are provided. The insulating terminal panel is rigidly secured to the transformer frame, and heavy-current, bus-bar-type terminals are securely bolted to the panel. The two outpout terminals each have two connection surfaces, one on a vertical plane and one on a horizontal plane, for maximum convenience in connecting the heavy current leads and in changing, when necessary, the series-parallel links. The links and the output connections cannot interfere with each other. All terminals and connection links are plated
-
Product
High Current Probe/DMM
655
-
Another great tool for all around electrical troubleshooting. The #655 is ideal for all high current applications, especially starting and charging diagnostics. The #655 can measure up to 1000 Amps AC or DC. Unit features built-in degrees F and C temperature readings.
-
Product
Current Caliper
KH23101
-
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
Product
Control Transformers
-
ENTES control transformers ensure the safe operation of measuring devices with 24 VAC supply voltage for electical control panels. Input voltages of Control transformers are either fixed (230 or 400V) or selectable with taps (400;230+15-15).
-
Product
Current Sources
-
Innovar Current Sources are the standard in the circuit breaker industry. Our Current Sources supply regulated current from 1 amp to 100,000 amps with incredible accuracy, along with providing a full set of features that is unmatched by any other Current Source in the market.
-
Product
Fourier Transform Infrared Spectroscopy (FTIR)
-
Rocky Mountain Laboratories, Inc.
FTIR Analysis is used to analyze organic materials. Bulk and small particle materials can be analyzed. FTIR microscopy analysis allows for the identification of particle as small as 10 µm.
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
High Current Probe
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Current Meter
Model 106
-
The Model 106 is the ideal instrument for coastal and estuarine applications and other light-duty survey work.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
Transformer Oil Tester
GTD-61A
-
1. The GTD-61A Automatic Oil Tan Delta(OTD) & Oil dielectric loss tester is highly automated, allowing for the measurement of temperature rise, dielectric loss, and resistance in one go.
-
Product
NI-9265, 4-Channel C Series Current Output Module
779334-01
Current Output Module
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.





























