Oscilloscope Probes
probe with lead for single-ended measurements connected to ground.
See Also: Oscilloscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes
-
Product
Passive Oscilloscope Probes
5900 SERIES
-
Probe Master's new 5900 series passive oscilloscope probes are available in 400 MHz & 500 MHz bandwidths. Probes are also available with readout actuators for oscilloscopes with the readout feature. The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.The probe body is made of high impact ABS. Soft molded strain reliefs at all stress points assure long cable life. In short it has been designed to offer you high performance coupled with high quality.
-
Product
Oscilloscope Probes and Accessories
-
Teledyne LeCroy has a wide variety of world class probes and amplifiers to complement its product line. From the ZS high impedance active probes to the DH Series Differential High-bandwidth Probes which offers bandwidths up to 30 GHz, Teledyne LeCroy probes and probe accessories provide optimum mechanical connections for signal measurement.
-
Product
Oscilloscope Probes
-
Connections to the ground of Oscilloscope Probes with the mini PCM Parrot Clip provide improved accessibility , reliability and accuracy. Ground clips for the oscilloscope probe were usually alligator clips but they have poor accessibility in narrow places due to the large jaws.
-
Product
Low Voltage Differential Oscilloscope Probes
-
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!
-
Product
USB Oscilloscope Probes
-
High-performance, passive accessories designed for use with their PC-based oscilloscopes.
-
Product
SA1000X, 1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784255-01
Oscilloscope Probe
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Probes
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
T3DSO Passive Probe, 350 MHz, 1X/10X, 1 MOhm/10 MOhm, 300V/600V
T3PP350
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
Oscilloscope Probe
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Differential Voltage Probes
DP150/DP200pro
-
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
Product
SA1500X, 1.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784256-01
Oscilloscope Probe
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
Product
WiFi Oscilloscope Probe
IkaScope
-
IkaScope is a wireless oscilloscope probe. It fits perfectly in your hand and works with any connected screen, like a laptop, a tablet or smartphone. Thanks to ProbeClick® technology, IkaScope knows when to measure and when to hold. IkaScope transfers measured signals over high speed wifi connection. 200 MSa/S Sampling rate. 30 MHz Bandwidth. 80 Vpp Input range. AC/DC Coupling. 4000 ptsMemory. 200 FPS Max. refresh rate.
-
Product
Oscilloscopes
-
Get your products to market faster with award-winning oscilloscopes that offer the fastest update rates, the deepest memory, the industry’s only capacitive touch screen, and the most oscilloscope software options Produce the highest-performing products with measurements you can trust thanks to oscilloscopes with industry-leading signal integrity and the largest selection of oscilloscope probes Achieve the lowest cost of ownership with multiple instruments in one mainframe and easy upgrades
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Power Integrity Analyzer Reference Solution
-
The power integrity analyzer reference solution is a hardware-based solution with the Keysight Infiniium S-Series 10-Bit ADC oscilloscope and probes, including the N7020A power rail probe that lets you see the true AC power noise on your DC power line and supports up to +/- 24 V offset and the N2820A high-sensitivity current probe that can measure down to 50 uA.
-
Product
10:1 500 MHz 10 MOhms Passive Probe
PP005A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MO. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
DC-to-250MHz, X1/x10 Probe Kit (HP-3250i), Isolated BNC
PRB-HP-3250i
-
Oscilloscope Probe 1:1-1:10 - HP-3250i250 MHz bandwidth, rated 600 V.The Oscilloscope Probe 1:1-1:10 - HP-3250i is a 1:1-1:10 selectable passive high impedance oscilloscope probe with 250 MHz bandwidth (1:10) designed and calibrated for use on oscilloscopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with an oscilloscope having an input capacitance of 10 to 30 pF.
-
Product
Probes And Accessories
-
Choose from a broad portfolio of Tektronix probes and accessories, all perfectly matched to our industry-leading oscilloscopes. With over 100 choices available, select the oscilloscope probe you need for your specific testing application. Download our Probe Selector Guide here.
-
Product
AC/DC Current Probe, 100 MHz, 15A
N2893A
Oscilloscope Probe
The Keysight N2893A is a 100 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features flat bandwidth (DC-100MHz), low noise(<2.5 mA rms) and low circuit insertion loss. Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe. The probe is powered directly by the InfiniiVision and Infiniium Autoprobe interface, eliminating the need for an additional power supply.
-
Product
Passive Probe, 10:1, 500 MHz, 1.5 M
10073D
Oscilloscope Probe
The Keysight 10073D passive probe is our most rugged 500 MHz probe. With a 10:1 attenuation ratio and high 2.2 M ohm input impedance, it is ideal as a general purpose, high bandwidth passive probe for the Keysight 300 MHz - 1 GHz 6000 series, 7000, 8000 and 9000 Series oscilloscopes. The probe identification feature automatically configures the oscilloscope for the probe attenuation.
-
Product
Isolated Hall Effect Current Sensors
-
Isolated Hall Effect current sensors provide accurate high bandwidth current sensing. Vektrex offers models to 320A. For use, the 50-ohm voltage output is connected directly to an oscilloscope or data acquisition system. VCS sensors are magnetically isolated like clamp-on oscilloscope probes. With secure cable attachment, repeatability is ensured.
-
Product
ProBus Probe Adapter for TekProbe-BNC Probes
TPA10
-
- Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes





























