Current Detectors
-
Product
Portable Eddy Current Flaw Detectors
-
Portable eddy current (EC) flaw detectors inspect metallic parts and perform highly reliable and advanced flaw detection of surface and near-surface defects. Olympus offers portable eddy current equipment to meet a broad range of applications, including the detection of surface or near-surface defects, and the inspection of bolt holes.
-
Product
Rotating Bolthole Scanners
Nortec
-
Olympus extensive line of high performance eddy current scanners is available for use with Nortec Eddy Current Flaw Detectors. With a wide range of features consisting of speed ranges from 600 to 3000 rpm, frequency ranges from 100 Hz to 6 MHz, multiple connector types, and multiple probe types, our scanners offer a full range of application solutions.
-
Product
Current Detectors
-
On our website you will find current detectors that are ideal for measuring AC or DC voltage. Current detectors are irreplaceable for inspection work and maintenance. We offer the following: voltage detectors, voltage leak detectors, voltage power detectors, Current clamps ideal for measuring AC or DC voltage. metric detectors, current detectors and more. These high quality current detectors include the capacity to measure many other parameters, such as capacity, resistance, power (both by way of clamps or by means of a hand held digital device with external clamps with a range of one or three stages). The current detectors are like the majority of our measurement instruments in that they meet and excel ISO standards. This calibration is done in a laboratory and comes with an accompanying certificate. All of our current detectors can perform the demanding tasks in each industrial sector regardless of the technical problem you encounter. If you can't find the current detectors you are looking for, please contact us and we will help you find the best solution to suit your needs by calling our offices on: UK customers +44(0) 23 809 870 30 / US customers (561) 320-9162 and our technical staff will advise you regarding our measuring instruments. Our engineers and technicians will be happy to help you with the current
-
Product
Electric Shock Protection Analysis
-
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
Product
Clamp Meters
-
The clamp meter is ideal for measuring AC or DC voltage. The instrument is irreplaceable for inspection work and maintenance in various industrial applications, in research and development, in residential applications and in many small businesses or households. The PCE line of clamp meter is made according to the highest industry standards and very important: PCE offers instruments that are usable in all workspaces (equipped with very small or even very large jaws), the results are reliable and the clamps are easy to use. Every clamp meter is manufacturer calibrated and can be certified to ISO or NIST - hold a PCE clamp meter in your hands and you can feel the quality immediately.PCE offers a variety of models: Voltage detector, voltage leak detector, voltage power detector, metric detector and current detector. In addition many clamp meters are able to measure other parameters, such as capacity, resistance and power - power through clamps directly or by handheld digital instruments with external clamps (with a range of one or three stages). Very often the clamp meter is a real multimeter - so it becomes a general electrical measurement tool.
-
Product
Eddy Current Flaw Detectors
EddyView
-
United Western Technologies Corp
Choose the Eddy Current performance to match your NDT inspection needs!
-
Product
Optical Radiation Meter
ORM400
-
The ORM400 Optical Radiation Meter has a USB 2.0 interface and is supplied with powerful calibration features and data display functions. It is ideally suited to display the measurements from the DH400 range of detectors as well as third party current generating detectors.
-
Product
General ELCB Testers
TEL1-x Series
-
Standard Electric Works Co., Ltd
The TEL1 is the Basic Test Equipment an Electrician cannot do without. TEL1 is a Dual Function Test Instrument utilized to Verify Electrical Wiring Connections and the Functioning of Earth Leakage / Residual Current Detectors devices by forcing the ELCB/RCD to trip.
-
Product
Planar-Doped Barrier Diode Detector, 0.01 to 33 GHz
8474C
-
The Keysight 8474C is a high-performance detector using a gallium arsenide, planar-doped barrier detecting element. It features extremely flat frequency response over its entire band of operation and very good frequency response stability versus temperature. The Keysight 8474C is also very rugged with high resistance to ESD damage. The Keysight 8474C detector is available with a 3.5-mm (mates with SMA, 0.01 to 33 GHz) connector. This detector offers the options for optimal sqaure-law loads (Option 102) and for positive polarity output (option 103). Because the unit-to-unit frequency response tracking of this device is typically better than 0.3 dB, no matched response option is offered.
-
Product
Low-Barrier Schottky Diode Detector, 10 MHz to 18 GHz
8473B
-
The Keysight 8473B Low-Barrier Schottky Diode (LBSD) detector has been widely used for many years in a variety of applications including leveling and power sensing. It offers good performance and ruggedness. Matched pairs (Option 001) offer very good detector tracking.
-
Product
Waveguide Detector, 26.5 to 40 GHz
R422C
-
The Keysight R422C is an 26.5 to 40 GHz GaAs planar-doped barrier diode detector. This waveguide detector has negative output polarity.
-
Product
Low-Barrier Schottky Diode Detector, 0.01 to 18 GHz
33330B
-
The Keysight 33330B low-barrier schottky diode detector has been widely used for many years in a variety of applications including leveling and power sensing. It offers good performance and ruggedness. Matched pairs (Option 001) offer very good detector tracking.
-
Product
Low-Barrier Schottky Diode Detector, 10 MHz to 18 GHz
8470B
-
The Keysight 8470B 18 GHz Low-Barrier Schottky Diode (LBSD) detector has been widely used for many years in a variety of applications including leveling and power sensing. It offers good performance and ruggedness. Matched pairs (Option 001) offer very good detector tracking. A video load (Option 002) extends the square-law region to at least 0.1 mW (-10 dBm).
-
Product
Brute High Current Probe
P4301-2R
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Brute High Current Probe
P4301-2F
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
-
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Brute High Current Probe
P4301-1R
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
High-Voltage Differential Probe, 200 MHz
N2805A
-
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
Product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Planar-Doped Barrier Diode Detector, 0.01 to 18 GHz
8474B
-
The Keysight 8474B is a high-performance detector using a gallium arsenide, planar-doped barrier detecting element. It features extremely flat frequency response over its entire band of operation and very good frequency response stability versus temperature. The Keysight 8474B is also very rugged with high resistance to ESD damage. The Keysight 8474B detectors are available with 0.01 to 18 GHz and a type-N connector. This detector offers options for optimal square-law loads (Option 102) and for positive polarity output (Option 103). Because the unit-to-unit frequency response tracking of these devices is typically better than plus or minus 0.3 dB, no matched response option is offered.
-
Product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
-
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
-
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
High Voltage Probe, 100:1, 3.7 KVpk, 500 MHz
10076C
-
The Keysight 10076C 3.7 kVpk, 100:1 passive probe gives you the voltage and bandwidth you need for making high-voltage measurements. Its compact design makes it easier to probe today's small power electronics components, and its rugged construction means it can withstand rough handling without breaking.
-
Product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
783731-01
-
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
780968-02
-
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
HPC High Current Probes, 100 – 187 mil (2.54 – 4.75 mm)
HPC
-
100 – 187 mil (2.54 – 4.75 mm)
-
Product
NI-9265, 4-Channel C Series Current Output Module
779334-02
-
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
NI-9208, 500 S/s, ±20 mA, 16-Channel C Series Current Input Module
785041-01
-
500 S/s, ±20 mA, 16-Channel C Series Current Input Module - The NI‑9208 is designed with industrial systems in mind. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing the overall per channel cost of the system. The NI‑9208 uses a standard D‑SUB connection for use with cables and connector blocks.
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
NI-9266 , 8-Channel C Series Current Output Module
785046-01
-
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.





























