High Voltage Probes
handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.
See Also: High Voltage Meters
-
Product
Test Probe Connector, High Voltage, Voltage, 3 %
72-6530
-
The 72-6530 is a high voltage Testy Probe with built-in meter measures voltages up to 40kVDC.
-
Product
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3605A
-
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
Accessory Kit for High Voltage Differential Probe
PK-HV-001
-
Accessory kit for High Voltage Differential Probe
-
Product
High Voltage Probe
HVP-40DM
-
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
Product
400 MHz High Voltage Differential Probe
DP0001A
-
The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV CAT III rating designed for making accurate high-voltage power measurements required for testing today’s WBG power devices, power converters or motor drives.
-
Product
High Voltage Probe: Single-Ended
-
A high voltage single-ended probe is typically used for measuring ground referenced signals up to 40 kV. However, some single-ended probes are designed for oscilloscopes with isolated or floating inputs for measurements that are not ground referenced. Users should select probes with a low input capacitance specification (< 4 pF) to minimize the probe’s loading effect on the circuit because a probe with lower input capacitance will offer higher input impedance at higher frequencies.
-
Product
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
AP031
-
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
Other Passive Probes
-
Probes connect the input of the oscilloscope to test points on the device under test (DUT). There are many types, including: high impedance passive, low capacitance, single-ended active, differential active, high voltage, and current probes. This is the first in a series of three articles on probe selection and application, and will focus on passive probes. Part 2 and part 3 will address active probes and current probes, respectively.
-
Product
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A
-
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
Attenuation 100 High Voltage Passive Probe
-
Safe high voltage probe solutions for ground-referenced voltage testing. It is critical to safely and accurately capture real-time signal information from "elevated" or "floating" voltage systems.
-
Product
High Voltage Non-Contact Current Probe
P02-0802
-
The TESCO High Voltage Non-Contact Current Probe (Catalog No. P02-802) was developed using current sensor technology. It is a two-piece, True RMS ammeter with a fiber optic link between the high voltage sensor and the readout at ground potential. The sensor is mounted on a hotstick and slipped over a high voltage line.
-
Product
High Voltage Probe
HVP-40
-
*MAX. Voltage : DC : 40KV, AC : 28KV, (50/60Hz only) CAT II.*1000MΩ Input Impedance.*Accuracy **DC: ± 1% to 20KV. ± 2% to 40KV. **AC: -5% to -10% (50/60Hz)*Division Ration : 1000:1*CE, TUV GS, UL, CUL, IEC1010
-
Product
High Voltage Probe
PD-28
-
Kusam Electrical Industries Limited
Most Digital Multimeters can measure AC Voltage up to 750 /1000V and DC Voltage upto 1000V DC. To extend the measuring range of the digital multi meter for low - power , high - voltage , high impedance circuits such as TV, Video Monitors.
-
Product
Probe Oscilloscope High Voltage
-
High voltage probes allow safe and accurate voltage measurement using your oscilloscope.
-
Product
1kV, 80 MHz High Voltage Differential Probe with 6m Cable and Auto Zero Disconnect
HVD3106A-6M
-
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
T3 Low & High Voltage Differential Probes
T3 Series
-
Teledyne Test Tools Low & High Voltage Differential Probes offer end user versatility with all models powered by an external universal power supply and work with any Oscilloscope with a high-impedance BNC input. The range consists of one Low Voltage and three High Voltage models with varying bandwidths to satisfy a wide array of customer applications.
-
Product
High Voltage Passive Probes
-
The PPE6KV-A and HVP120 can handle up to 6000 Vpeak transient overvoltages and are designed for probing up to 2000 Vrms and 1000 Vrms respectively. Fast rise times, excellent frequency response, and a variety of standard accessories make these probes safe and ideal for high voltage measurement applications
-
Product
High Voltage Probe
PL-10
-
*MODEL:PL-10*IMPEDANCE:1.111MΩ*ACCURACY: ±0.25%*FREQUENCY B.W.:DC~50MHz*WORKING POWER:MAX. 1Watt*INPUT VOLTAGE:MAX.250VDC or 200V rms AC*DIMENSION:46mm(L)xΦ16mm(D)*WEIGHT:25g
-
Product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
-
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
Product
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A
-
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
High Voltage Probe, AC or DC Measurement, 40 kV, 1000 MΩ
72-3040
-
A high voltage probe that allows most 10MΩ multimeters to be turned into a high voltage meter.
-
Product
Brute High Current Probe
P4301-2R
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
-
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
Brute High Current Probe
P4301-2F
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
-
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Brute High Current Probe
P4301-1R
-
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
High-Voltage Differential Probe, 200 MHz
N2805A
-
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
Product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02