References
A source of comparison.
See Also: Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transformers, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
Nonferrous Metal Reference Materials
-
NCS Testing Technology Co., Ltd.
Nonferrous Metal Standards
-
Product
RF One Power Meter
-
The RF One Power Meter is a very versatile instrument covering both analog and digital carriers in an extremely wide frequency range from 30MHz to 6GHz. The RF One is capable of measuring forward and reflected power in the range of a few milliwatts up to 500 Watts. The internal operating system controls measurement, display and the I/Os allowing serial communication to PC, USB to memory stick and USB Serial communication. The I/O options are used to write plots to either memory sticks or to a connected PC, the I/Os can also be used to operate the instrument, giving commands and receiving data. For documentation reference the instrument has a real time clock. Multilayer menus are used to setup and control the operation of parameters. The RF One instrument is small, handy and light weight battery operated with more than 3 hours of continuous operation on the internal NiMh cells. Feature with XML data handling and application viewer is included. Accessory kit with soft carrying bag, car charger and coax adapters for standard types.
-
Product
Boresight Systems
-
Boresight is a process to align optical axis of single system or a series of optical or electro-optical systems with a certain reference optical axis or mechanical axis. Proper boresight is particularly critical in case of multi-sensor electro-optical surveillance systems built from a series of systems like thermal imager, VIS/NIR camera, SWIR camera, laser range finder, laser pointer.
-
Product
Piston Gauges
-
Fluke Calibration piston gauges provide reference level primary pressure measurements for some of the top laboratories in the world. Our piston gauge lineup includes models that offer full automation. Our primary level pressure balances utilize a fundamental equation to determine generated pressure with very low levels of uncertainty. Piston gauge models include PG7000 and PG9000 DHI systems with AMH automated mass handling and other automation hardware; 2465, 2468, 2470 and 2485 Ruska piston gauges and 24xx differential pressure cell and other piston gauge accessories; FPG8601 DHI very low pressure standard; 2482 Ruska differential pressure standard. Standard pressure calibration.
-
Product
MuClock
-
Our Muclock is the only commercially available time & frequency reference based on quantum manipulation of laser cooled atoms in the world. This unique solution is the result of more than 15 years of experience acquired by our academic partner, LNE-SYRTE, one of the major international experts in the field of time standards.
-
Product
MCX Male to SMA Male Cable, 50 Ohm, 30 cm
188377-0R3
Coaxial Cable
The MCX-SMA Coaxial Cable, sometimes referred to as MCX400 or MCX410, connects measurement and signal devices. NI offers this 50 ohm cable in different lengths.
-
Product
VXI Switching
-
The Aerospace and Defense industries were early adopters of modular test platforms. One of the first successes was VXI test systems and VXI switching. They served these industries very well for more than 20 years. Now, as VXI test systems become obsolete, test systems developers are looking to PXI as the next generation modular test platform for their industries. We offer a few different references to help you in making a switch to PXI.
-
Product
BigRef
-
Calibrate your sun simulators with utmost precision thanks to IMT Technology’s large-scale BigRef reference cell.
-
Product
Nephelometric Turbidity Sensor
DTF16
-
The DTF16 is a high 3 channel turbidity sensor for installation into pipelines, measuring turbidity at two angles of scattered light and a direct reference channel in various liquid flow streams.
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Dipole Antenna
AD-100
-
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
Product
0.50° Accuracy Full Attitude Surface Dynamic Motion Sensor
DMS-550
-
The DMS range of motion sensors is designed specifically for the motion measurement needs of the marine industry. Whether it is achieving IHO standard survey from any size of vessel, or providing safety critical monitoring of offshore platforms, large vessels, helicopter landing decks, cranes and positioning systems, the DMS provides accurate motion measurement in all sea conditions. Incorporating an enhanced external velocity and heading aiding algorithm for improved accuracy during dynamic manoeuvres, the solid state angular rate sensors offer reliability in the highest performing vertical reference units ever produced by TSS.
-
Product
Crossed-Roller Bearing Linear Stage ,25mm Travel XY,Sensitivity 1um
NFP-2462
-
Model:NFP-2462 Crossed-Roller Bearing Linear Stage ,25mm Travel XY,Sensitivity 1um DetailsSpec: Please refer to NFP-1462 Specification,It is combinated by 2pcs NFP-1462(C,SR,SL)
-
Product
Low Noise Differential Preamplifiers
-
Provide a high gain amplification to 1MHz with an AC output derived from a very low noise FET instrumentation amplifier. Each model has fixed gain settings of x1 (0dB), x10 (20dB), x100 (40dB) and x1000 (60dB) over a selectable bandwidths of 100Hz, 1kHz (HP), 3kHz, 30kHz, 100kHz and 1MHz (7000 model only). Noise referred to input is 7nV√Hz and common mode rejection is >100dB at 1kHz. Momentary pushbutton switches are provided that control coupling, bandwidth, gain and channel on/off selections. BNC connectors are provided for single-ended and differential input, ac output, and dc output (optional) connections.
-
Product
2-Ch 500 MHz A/D with DDC & 2-Ch 800 MHz D/A with DUC, Virtex-7 FPGA - XMC
Model 71751
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- Two 500 MHz 12-bit A/Ds- Two multiband DDCs (digital downconverters)- Two 800 MHz 16-bit D/As- One DUC (digital upconverter)- Multiboard programmable beamformer- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- VITA 42.0 XMC compatible with switched fabric interfacesOptional LVDS connections to the Virtex-7 FPGA for custom I/OAlso available in 3U VPX, 3U & 6U cPCI & PCIeSupports GateXpress® FPGA-PCIe Configuration ManagerSynchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Ultrasonic Sensing
-
Ultrasonic sensing is the measurement of the time between an ultrasonic signal being sent and received. The interval between these two signals is typically referred to as time-of-flight (ToF) and depends on the distance the ultrasonic wave travels until it is reflected due to an impedance change and the speed of the ultrasonic wave. The basic equation time = distance / speed can be used to measure fluid level, fluid identification/concentration, flow, or proximity.
-
Product
3-Channel 200 MHz A/D and 2-Channel 800 MHz D/A with Virtex-6 FPGA - 3U VPX
Model 52620
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Supports gigabit serial fabrics including PCI Express, Serial RapidIO and Xilinx Aurora- Three 200 MHz 16-bit A/Ds- One digital upconverter- Two 800 MHz 16-bit D/As- Up to 2 GB of DDR3 SDRAM or 32 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factors provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
3D Software
Geomagic Control X
-
Combined with the powerful and highly precise Artec 3D scanners, Geomagic Control X is a fantastic solution for anyone looking for speed, accuracy and a large variety of tools to choose from. Easily get the data required for extensive quality control in no time at all with Artec’s advanced 3D scanning solutions. Acquire precise measurements and carry out inspection and data analysis on the spot, using Geomagic Control X and an Artec 3D handheld scanner. Compare 3D scans to the reference CAD model to minimise assembly flaws and increase productivity.
-
Product
Isolation Measurement System
DM-8000H
-
*The input block, control block and display block are isolated with optical fiber cables. (DM-900A/AL, DM-910A/AL)*Frequency bandwidth: DC to 500MHz.*Simultaneous multi-channel measurement of many channels of different reference potentials. (2 to 24 channels) (DM-900A/AL)*Long-life battery drive. (The system can be driven by three batteries for about 12 hours) (DM-900A/AL, DM-910A/AL)*Measurement using long memory. (DM-900A/AL, DM-910A/AL)*Simultaneous measurements of the inverter's switching waveform and ON-voltage. (DM-910A/AL)
-
Product
Rubidium Frequency Standard
RFS VXI
-
*RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.
-
Product
Programmable Multifrequency Clock Synthesizer - 6U VPX
Model 5891
-
- Simultaneous synthesis of up to 10 different clocks- 16 SMC clock outputs- Typical phase noise: -105 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 to 100 MHz- Eight programmable VCXOs with 32-bit tuning resolution- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 700 MHz- Control and status over the VPX backplane
-
Product
Frequency Reference
E8-X
-
The Quartzlock E8-X is a breakthrough in exceptionally low cost, miniature, traceable, calibration-free, off-air frequency & time standards. These references maintain the high frequency & time accuracy required for demanding applications.
-
Product
Current Sensing
-
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
Product
16-Channel 250 MHz A/D with DDC, Kintex UltraScale FPGA - 6U VPX
Model 58131
-
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Ideal radar and software radio interface solution- Supports two Xilinx Kintex UltraScale FPGAs- Sixteen 250 MHz 16-bit A/Ds- Sixteen multiband DDCs (digital downconverters)10 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available
-
Product
pH 700 Benchtop pH Meter
-
The easy-to-use, microprocessor-based pH 700 benchtop meter measures pH, mV, relative mV, and temperature. The large, dual-display LCD provides excellent visibility—even from a distance. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Five-point pH calibration, with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers, makes for easy calibration no matter which requirement you need to meet. Meter features HOLD, ATC, selectable °F or °C measurement, recall of electrode slopand offset, and electrode diagnostics. The convenient pull-out quick reference card keeps procedures handy at all times. Meter accepts any pH or ORP electrodes with a BNC connector.
-
Product
Low Cost Microwave Wideband Electro-absorption DFB Transmitter (without RF Amp)
MT60 (40KHz~33GHz)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
MT60 series microwave DML optical transmitter, are able to transmit 33G microwave RF signal with long distance, wide bandwidth, and flat responsibility. They provide an outstanding linearity fiber optical communication for analogue and digital wideband microwave application. Due to avoidance of using expensive coaxial cable or wave guide, there will be no limitation in transmission distance, which improves the signal quality and reliability of the microwave communication. They can be widely applied in microwave communication system such as remote wireless; timing and reference signal distribution, telemetry, measurement and delay line etc as well as 10Gb/s and 60Gb/s high speed communication system.
-
Product
Upright Microscopes
-
ACCU-SCOPE upright microscopes deliver top quality optics for bright, crisp images. Sometimes referred to as compound microscopes, our upright microscopes are favorites across a wide range of laboratories including clinical, veterinary, pharmaceutical, research, university, and education. Some of the disciplines utilizing our upright microscopes include pathology, hematology, microbiology, cytology and histology. ACCU-SCOPE upright microscopes offer a selection of magnifications from ultra-low (e.g. 2X) to high power oil immersion (e.g. 100X). Our microscopes have a variety of options and accessories to perfectly fit your application including ergonomic viewing heads, trinocular heads for camera attachment, and an assortment of objectives. Common contrast methods used with our microscopes include brightfield, phase contrast, darkfield, Differential Interference Contrast (DIC) and fluorescence.
-
Product
PCIe Direct Digital Synthesizer
-
These devices provide two synchronized DDS-based RF channels on a single PCI card. With fine frequency, amplitude and phase control the Synth1000 products enable a number of advanced applications at a fraction of the cost of conventional equipment. In addition to two analog outputs the Synth1000, up to 4 separate profiles may be dynamically selected using externally supplied TTL signals for low-latency triggered operation such as PSK, FSK, and triggered sweep operation. Software support for Windows 8, 7, Vista, Windows XP and Linux is included. LabVIEW Labview source code available. For detailed specifications, please refer to the Synth1000 Manual.
-
Product
Glow Wire Test Apparatus
-
GLOW WIRE TESTER (also known as Glow Wire Test Apparatus) is designed to carry out fire hazard testing as specified in IEC 60695-2-10 2000-10. Flammability test is to check the ‘Resistance to Fire’ of electrical insulators that touch directly conducting parts & also parts of insulators. This test is also referred in many other standards such as IS 11000, IS 3854 : 1997 / IS 1293 :1988 / IS 371 :1999 & IS 11000 Pt 2 Sec 1, IEC 60335, IEC 884/94, IEC 60598, IEC 61058, BS 6458, BS EN 60695–2-10,11,12, etc.
-
Product
Standard Capacitors
1408 Series
-
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.





























