Current Loops
See Also: Loop, HIL, Loop Testers
-
Product
PCI Express 8 Reed Relay Output
8012eS
-
The 8012eS PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
Product
PAT and Installation Verification Unit
PowerCheck 1557
-
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
Product
Digital Electrical Network Analyzer
1826 NA
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
Product
4-20mA Current Loop D/A Converters
-
ADI integrated solutions combine both the D/A converter and driver in one chip to provide the required output directly from the digital domain. Analog Devices’ portfolio of leading industrial D/A converters and drivers provides a range of programmable output ranges from standard 4 mA to 20 mA for current loop communication to ±10 V for actuator control. ADI industrial converters offer considerable control functionality and advanced on-chip diagnostics to maximize system uptime, as well as eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
Product
Fuse Buddy Current Loop
307M/308B
-
*Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps
-
Product
Industrial 4-20mA Driver
-
Analog Devices portfolio of leading industrial d/a converters and drivers addresses the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
Product
- RS-232 to Current Loop Converter
Model 65A
-
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
Product
HART Protocol Stack
softHART
-
SoftHART is the industry-standard smart HART (Highway Addressable Remote Transducer Protocol) communications stack for industrial automation. HART is a bidirectional protocol and communicates over existing 4-20 mA analog current loops, extending communication capabilities without the inconvenience of installing additional wiring.
-
Product
Industrial 4-20mA Driver
-
Analog Devices portfolio of leading industrial d/a converters and drivers addresses the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 12 Channel
43-765-002
-
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
PXI Analog Output / Current Loop Simulators
-
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
Product
Signal Isolators & Converters
-
Devar current loop signal isolators reduce problems found in field measurements when signal transmitters or converters encounter both input and output signals that may be grounded. Current loop isolators eliminate these ground loops and are available as input loop powered or output loop powered instrumentation.
-
Product
12 D/A Outputs (±10 VDC or ±25 mA)
DA1
-
The DA1 module features 12 independent D/A output channels with a full-scale range of ±10 VDC at ± 25 mA (max). The DA1 provides either voltage or current control loop modes that are programmable for the particular application. The DA1 module also offers external trigger/synchronization signal (RS422/485) capability, which provides/accepts a trigger signal to/from other module(s).
-
Product
Digital LOOP/PSC/LOAD Tester
1825 LP
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.
-
Product
4-20mA Current Loop USB Data Logger
EL-USB-4
-
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
Product
Current Loop Expansion Kit
OP-SB85C
-
This expansion kit supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 16 Channel
43-765-001
-
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Temperature Transmitter
T4111
-
Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.
-
Product
4 (High Current) D/A Outputs (±40 VDC or +100 mA)
DA3
-
The DA3 module features 4 high-current D/A output channels with a full-scale range of ±40 VDC or ±100 mA (max). The DA3 provides either voltage or current control loop modes that are programmable for the particular application.
-
Product
DC current Sensors
CTH
-
The CTH sensors convert dc current to an isolated voltage output, the CTHR sensors convert ac current to a dc output signal proportional to the Arms. All popular process control voltage and current loop outputs are available. Through hole or split core options mean that connection is non-intrusive and straightforward. The available input range of the CTH sensors is any value from 5A to 6000Adc.
-
Product
Intelligent Transmitter with Digital Indication
LEO 3
-
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions:
-
Product
PC Based High Current Test Set for Circuit Breakers and Temperature Rise Test Equipment
-
This equipment comprises of high current source for testing of circuit breakers with additional facility for temperature rise testing (thus incorporating testing for moulded case, vacuum & air circuit breakers as per IEC 60947-2). The system integrates a servo controlled source with closed loop current feedback to maintain the current constant. It has the necessary instrumentation for maintaining current at full load & other conditions arising in testing at high current. The bench has a PC based control system with temperature data logger (24 channel with ch-ch isolation amplifiers). The data logger displays as well as stores a set of temperature values with time.
-
Product
Analog & Digital I/O Modules
-
USB analog and digital I/O modules are a complete family of data acquisition modules for use in process control systems. The analog input modules can measure process signals such as DC voltage, thermocouples, 4-20mA current loops, discrete contact closures.
-
Product
Opto-Isolated Current Loop Signal
4029
-
SPECTEC Innovative Sensor Solutions
SPECTEC's Model 4029 digital opto-isolated current loop signal conditioner prevents ground loops and interrupts any galvanic signals riding on magnetic speed sensor's output signal.. This signal conditioner converts magnetic, variable reluctance and inductive sensors' sinusoidal signals into a 4-20 mA output suitable for interfacing with process control units, dataloggers, flow controllers, and computers.
-
Product
Industrial 4-20mA DAC Solution
-
Analog Devices portfolio of leading industrial digital-to-analog converters address the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
Product
Rechargeable Multifunction Tester
ET4000
-
The new ET4000 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.
Everything about the new ET Series has been designed to save time and make testing easier.
Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .
Supplied with a full range of accessories.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
-
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Digital LOOP/PSC/EARTH Tester
1824 LP
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. (you do not need to add all the bonding points and connection paths)● Displays voltage supply at the transformer(Line to Neutral), without loading the transformer.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto-off / Auto-ranging (software range).● Color-coded test leads.● Combined prospective short circuit current, loop, and earth tester.● Loop test for L-E and PSC between L-N.● Voltage test L-N.● Display can be customized for large orders.
-
Product
Microwave Moisture Meter
RX-95
-
The system works based on the absorption of microwave energy by water molecules contained inthe x-rayed material. It is a non-contact, non-destructive method of instant measurement of water content - used for materials such as coal, flour, grain, cement, seeds, sugar, etc. Thanks to high measurement sensitivity (resolution greater than 0.01% of water content by weight), short measurement time (about 5 times/sec.) and repeatability of measurement - the system is suitable for continuous measurement of material moisture, e.g. on conveyor belts and its recording on a PC or using a 4-20 mA current loop.
-
Product
PCI 16 Reed Relay Output / 16 Isolated Input Digital Interface (10-30V)
8004H
-
Optimized for sensing up to 24V inputs, the 8004H PCI digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The inputs protect the computer equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide high quality, long-life, low-current (10 Watt maximum), dry contact switch closures. The relays are normally open, and close when energized.