Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
Power Source Unit
SM7860
-
Power Source Unit Ideal for MLCC Leakage Current Measurement. The SM7860 series allows for setting the dual-line output voltage on 8 channels or 16 channels, and enables up to 32-channel of output. The Hioki SM7860-5x/SM7860-6x series is a 32-channel, 500V / 1000V power source for the Hioki SM7810 Super Megohm Meter, providing positive and negative polarities required for MLCC test lines.
-
Product
DC BIAS CURRENT UNIT
3265B SERIES
-
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 67GHz, 50Ω, SMA-1.85, Remote Mount
40-780B-571-E
Relay
The 40-780B-571-E (PXI) and 42-780B-571-E (PXIe) are single SPDT 67GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67GHz in 50Ω or 2.5GHz in 75Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50Ω and 1.6/5.6 in 75Ω versions.
-
Product
LXI Microwave Switch, 50Ω 5xSP6T Terminated & 7xSPDT 18GHz SMA
60-890-001
Microwave Switch Module
Model 60-890-001 is a mixed configuration Microwave Switch and is suitable for switching 50Ω signals up to 18GHz. With 5 banks of terminated SP6T and 7 banks of SPDT unterminated relays it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA connectors.
-
Product
Exclusive Control Unit For Safety Light Curtain
SF-C10
-
Panasonic Industrial Devices Sales Company of America
Exclusive Control Unit For Safety Light Curtain
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated Common, 3GHz, 50Ω, MCX
40-876A-102
Multiplexer Module
The 40-876A-102 (PXI) and 42-876A-102 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 3GHz, 50Ω, N-Type, Remote Mount
40-785C-562-E
Multiplexer Module
The 40-785C-562-E (PXI) and 42-785C-562-E (PXIe) are dual SP6T 3GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
EPON OLT ( Optical Line Termination )
OLT-1408
-
Hangzhou Huatai Optic Tech. Co., Ltd.
OLT-1408's Optical Line Terminal (OLT) adopts GiGA Ethernet Passive Optical Network (EPON) technology. It is a compact chassis with L2/L3 GiGA switching and routing function. All the functional components are modularized design and it supports hot-plugging with plugging and playing. 1~4 pieces of GiGA optical port or electrical port are optional in the uplink port, which provides a direct optical interface for the Ethernet/IP network core. 1~8 pieces of EPON optical port are optional in the down link port. Through a passive optical Network (PON), an optical Network unit link (ONU),it can provide final transmission with bandwidth up to 1Gbps for the user.
-
Product
PXI Dual SP6T Multiplexer 18GHz 50, SMA, Terminated
40-785B-522-T
Multiplexer Module
The 40-785B-522-T is a dual 6-channel 18GHz terminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
LXI Microwave Multiplexer, SP6T, 13-Bank, 50GHz, 50Ω, SMA-2.4, Terminated
60-800-713
Microwave Multiplexer
High performance RF multiplexer suitable for switching microwave signals up to 50GHz with automatic termination of unused signals
-
Product
Single 16 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-765A-001
Multiplexer Module
The 40-765A-001 terminated single 16 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
High Temperature Testing Mobile Conversion Unit
-
Used for applications that require high temperatures (1800C-2000C) for extended periods of time, the High Temperature Mobile Conversion Unit offers enhanced capabilities to accommodate more damanding requirements.The unit is based on the General Purpose MCU which allows for the use of standard specimen grips and accesories.
-
Product
AM Antenna Tuning Units
ATU's
-
LBA medium wave AM Antenna Tuning Units (ATU) and Line Tuning Units (LTU) are impedance matching units designed to match the transmitter to the impedance of the transmission line or the antenna system. Our Antenna Tuning Units are available for both series-fed and {ln:Tunipole antenna systems} Tunipole™ antenna systems to powers in excess of 500 kW.
-
Product
Remote Display Gas Monitor
Chillgard® 5000 Remote Display
-
The Chillgard® 5000 Remote Display provides gas monitor information before room entry where potentially hazardous gas levels may exist. It mimics the Chillgard 5000 Gas Monitor readings for gas concentration, alarm status, calibration.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 6GHz, 50Ω, SMA, Remote Mount
40-784B-003-E
Multiplexer Module
The 40-784B-003-E (PXI) and 42-784B-003-E (PXIe) are triple SP6T 6GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-021-E
Multiplexer Module
The 40-784B-021-E (PXI) and 42-784B-021-E (PXIe) are single SP6T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-533-TE
Multiplexer Module
The 40-785C-533-TE (PXI) and 42-785C-533-TE (PXIe) are triple failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Terminals And Test Points
-
Today's high tech electronics require space saving, low cost methods for connecting and testing circuitry. Our complete line of Quick Fit terminals, Screw Terminals, Solder Lugs and Test Points and Jumpers are designed to meet the interconnect and testing challenges for electronic and electrical component termination points.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-532-TE
Multiplexer Module
The 40-785C-532-TE (PXI) and 42-785C-532-TE (PXIe) are dual failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Octal 4 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-761-008
Multiplexer Module
This terminated octal 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI Remote Mount Single SP6T Multiplexer 40GHz 50, SMA-2.9, Terminated
40-785B-541-TE
Multiplexer Module
The 40-785B-541-TE is a remote mount single 6-channel 40GHz terminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
Phalanx Wireless Remote Controls
-
GrayStone Automation offers our Phalanx family of state-of-the-art, sustainable, energy efficient wireless remote control products for industrial, scientific and general automation applications.Our Phalanx wireless family include products for monitor & control instrumentation, wireless remote controls and off-grid solar power systems.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP12T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
40-788-222-E
Multiplexer Module
The 40-788-222-E (PXI) and 42-788-222-E (PXIe) are dual failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
Terminal Board for Mitsubishi MR-J3-A Servo Amplifiers
DIN-814M-J3A0
Amplifier
This well-designed motion control terminal board is for the users who use Mitsubishi J3A servo. With this terminal board, users can ealisy complete wiring with PCI-8174, PCI-8164, PCI-8154, PCI-8158 and PCI-8134.
-
Product
4-Slot USB 3.0 IDAQ Base Unit
iDAQ-934
-
Built-in USB 3.0 SuperSpeed hubWide-range power inputLED status indicatorsPhysical ID switch for multiple module identification4 x iDAQ slots2 x programmable function pins for timing signals (trigger, clock) input/output
-
Product
Single 8 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-763-001
Multiplexer Module
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI/PXIe RF Multiplexer, Dual 6-Channel, Terminated, 8GHz, 50Ω, SMA
42-881B-002
Multiplexer Module
The 40/42-881B has low VSWR characteristic over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensure a long service life with no wear out mechanism, making the module ideal for ATE systems requiring frequent and fast operating RF switching with no contact bounce.
-
Product
2-18GHz Instantaneous Frequency Measurement Unit
DR073
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.
-
Product
80 DIOs, 8AIs, 8AOs JTAG Boundary Scan Resources Unit Expansion
YAV9JTAH
Test Fixture
80 DIOs8 Ais8 AOsCompatible with all JTAG vendors