Compensators
-
Product
Automatic Battery
BATLV480
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
True RMS RF Millivoltmeter
3440A
-
The 3440A measures the true rms of low level RF and microwave signals to over 1GHz. High rms accuracy, traceable to NIST, is assured regardless of waveshape. Common calibration errors are eliminated through temperature compensation of the probe detector diodes; double shielding protects the interchangeable probes from rough handling and pickup. Relative gain or loss measurements are simplified by a 0 dB reference adjustment. DC output proportional to the ac input is provided for analog recorders and to allow operation as an ac-dc converter.
-
Product
AdBlue & Urea Refractometer
RHA-503ABATC
-
Fuzhou Zhongtuo Optoelectronic Co.,Ltd
The AdBlue refractometer RHA-503ABATC is a new hand held refractometer developed to address the growing need to check the urea concentration in AdBlue.Escalating urea prices have driven the cost of operating an SCR higher than ever before. Regretfully this has led to a new wave of problems where supplies of diluted AdBlue have found their way in to the market.Often rebranded ‘Automotive urea solution’ to eliminate the risk of prosecution by trading standards (as a mix of less than 31.8% urea cannot be labelled AdBlue). Victims of this weaker concentration may not be able to seek compensation under the Trades Description Act.
-
Product
sbRIO-9211, Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
780877-01
-
Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
Engine Simulator
MS 1118
-
Test Set-A calibration unit is a test jig is used to simulate parameters of Adour 804E and 811 engines of Jaguar aircrafts. It simulates current, voltage, speed, and turbine gas temperature. It performs NL Check, NH Check, TGT1 (Non T2 Compensated), TGT2 (T2 Compensated), Amp (Non T2 Compensated), Amp (T2 Compensated), Solenoid Volt, TGT Inject, NL Inject, and NL/TGT Redatum.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Salinity Meter with Electrode
Salt 6+
-
Automatic Temperature Compensation (ATC) for the optimum accuracy under fluctuating temperatures :: Hold Function momentarily freezes reading for easy viewing and recording
-
Product
Venable Stability Analysis Software
-
In 1983, Venable launched the renowned K-Factor Technique, still in use by many instrument manufacturers today. Venable has elevated the original software with its innovative Stability Analysis program. Go straight from measurement to design using Stability Analysis as its dynamic functionality eliminates lengthy manual value calculations and guesswork. Compensation amplifier synthesis capability, or coefficients for digital power supplies, enables user to achieve exact feedback loop bandwidth and phase margin desired on the first try.
-
Product
Handheld Water Quality Meters
LAQUA PC220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Passive Probe, 10:1, 500 MHz, 1.2 M
N2843A
-
The Keysight N2843A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
Product
RTD Data Logger
-
RTD Data Logger is the most commonly used sensors for measuring temperatures in various industries. These are positive temperature coefficient resistive sensors and Pt100 is the most commonly used type of RTD sensor which has 100 ohm resistance at 0 C. IM2000 series RTD data loggers offer bridge measurement technique to compensate for effect of wire length. In addition logger has facility to program offset so that the measurements are more accurate.
-
Product
Time Delays
-
Analog Devices time delay products feature delay control modulation bandwidth up to 2.5 GHz, as well as a 0 ps to 70 ps continuously adjustable delay range for some members of this portfolio. Monotonic delay compensation allows for stable operation over both power supply and temperature variations.
-
Product
Atomic Resolution Analytical Electron Microscope
NeoARM JEM-ARM200F
-
"NEOARM" comes with JEOL’s unique cold field emission gun (Cold-FEG) and a new Cs corrector (ASCOR) that compensates for higher order aberrations. The combination of a Cold-FEG and ASCOR enables atomic-resolution imaging at not only 200 kV accelerating voltage, but also a low voltage of 30 kV."NEOARM" is also equipped with an automated aberration correction system that incorporates JEOL’s new aberration correction algorithm for automatic fast and precise aberration correction. This system enables higher-throughput atomic-resolution imaging even at low accelerating voltages. Furthermore, a new STEM detector that provides enhanced contrast of light elements is incorporated as a standard unit.
-
Product
E-Series Average Power Sensor
E9301H
-
Measure the average power of all modulation formats Wide dynamic range power measurements from -50 dBm to +30 dBm10 MHz to 6 GHz frequency coverage for Wireless Comms formatsLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
Product
4 Thermocouples/RTD Ch
APCI-3200-4
-
18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel4 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 2 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated
-
Product
Handheld Water Quality Meters
LAQUA PD210
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
VHF True RMS Probe
-
The VHF True RMS Probe is a frequency compensated power probe capable of measuring power even in a multiple carrier installation. Regardless of physical waveform, the probe will measure the True RMS power of the signal. When used together with our Broadcast Power Monitor type 3024, you can add Web and SNMP capabilities to your mast site installation.
-
Product
Panel-mount Type Resistivity Meter (Four-Wire Transmission, 2-channel)
HE-960RW
-
HE-960RW connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.This resistivity meter is ideal for such applications as the high-precision water monitoring employed at ultra-pure water plants used in semiconductor manufacturing.They utilize newly designed, high-precision, high-stability temperature measurement circuitry and a vastly improved temperature compensation function, an important element for measuring the resistivity of ultra-pure water.
-
Product
Coordinate Measuring Machines
StentCheck®
-
High performance multisensor CMM with Integrated Werth Zoom® optic with magnification 0.7x – 6.8xRotary/Tilt Axis with high speed air bearing rotary axisRotary OnTheFly for fast measurementsContour image processing for fully automatic measurements of complex geometrical elements with sub-micron repeatabilityIntegrated goniometer (tilting axis) allows for the measurement of non-cylindrical geometriesUnique lighting design optimized for measurement of stentsTemperature compensation included
-
Product
Variable Attenuator
VAXE
-
The VAXE Variable Attenuators are waveguide components for tunable signal leveling or reflection compensation in waveguide networks. The Attenuators consist of waveguide section with a resistive film evaporated on the mica surface. The Attenuators has 0 ÷30 dB minimum attenuation range. The VAXE Attenuators are available in four waveguide bands between 33 GHz and 170 GHz.
-
Product
Infrared CO2 Analyzer
CI-IN261
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
CI-IN261 is based on NDIR principle and adopts digital processing technology as zero point/range point calibration, linear processing, temperature compensation, switch output, flow/voltage output, parameters setting etc. - See more at: http://en.ci-ele.com/sf/a55f582e-1bef-4eac-b401-bf24b8f7e1c8.shtml#sthash.6RCIN6uu.dpuf
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
PRO High Range Conductivity Meter
MW302
-
MW302 is a Portable Conductivity High Range (EC) Meter with Automatic Temperature Compensation. This instrument has been designed to meet the Grower's need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. It is also a great meter for food, labs, and water treatment applications.
-
Product
Temperature Measurement IR Sensors & Detectors
DR34 Compensated
-
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.
-
Product
Full Bridge Thin Beam Force Sensors
TBS SERIES
-
The TBS Series thin beam force sensors many different parameters found in medical instrumentation, home appliances, process control, robotics, and automotive are exceptionally suited for small load measurements. They are designed to measure and many other high volume applications. A specially developed integrated strain gage includes all balancing, compensating and conductive elements and is laminated to the beam to provide excellent stability and reliability.
-
Product
Compact Eddy Current Sensor System
eddyNCDT 3005
-
Compact and robust design. - Temperature compensation up to 180C. High precision measurement accuracy. High frequency response. Sensor for ferro- and non-ferromagnetic targets. Easy to use (plug & play). Perfect for machine integration.
-
Product
Pressure Balanced, Oil-Filled Hose
PBOF
-
Pressure Balanced, Oil-Filled (PBOF) hose assemblies from Teledyne ODI are designed and qualified to accepted industry standards. The double-walled hose design incorporates inner and outer elastomeric barriers with fiber reinforcements to withstand the demands of long performance life requirements in deep ocean interconnect and distribution applications. The hose is filled with non-conductive silicone oil, which acts as a pressure compensator and dielectric. The electrical and/or optical conductors are loosely housed within the oil-filled assembly.
-
Product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle
865682-01
-
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.