GHz
See Also: Gigahertz, GHz Synthesizers
-
Product
PXIe Microwave Multiplexer, Dual SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Failsafe
42-785C-532-T
Microwave Multiplexer
The 40-785C-532-T (PXI) and 42-785C-532-T (PXIe) are dual failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Active Probe, 2 GHz
N2796A
General Purpose Probe
The N2796A is a new generation of low-cost, single-ended active probe with the AutoProbe interface. The probe integrates many of the characteristics needed for today’s general-purpose, high-speed probing - especially in digital system design, component design/characterization, and educational research applications. Its 1MΩ input resistance and extremely low input capacitance (1 pF) provide ultra low loading of the DUT. This, accompanied with superior signal fidelity, makes this probe useful for most of today’s digital logic voltages. And with its wide dynamic range (±8 V) and offset range (±12 V), the probe can be used in a wide variety of applications.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP8T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-788-022-TE
Multiplexer Module
The 40-788-022-TE (PXI) and 42-788-022-TE (PXIe) are dual failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
Passive Probe, 100:1, 1.5 GHz, 1.3 M
N2876A
Oscilloscope Probe
The N2876A passive probe offers DC to 1.5 GHz and 100:1 attenuation factor to measure fast edges in high speed applications more accurately. This probe needs 50 Ω input on the oscilloscope.
-
Product
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV
RP4060
-
+/-60V offset permits the DC signal to be displayed in the vertical center of the oscilloscope grid with a high-sensitivity gain setting (maximum +/-800mV dynamic range).
-
Product
FieldFox Handheld Microwave Spectrum Analyzer, 26.5 GHz
N9938B
Spectrum Analyzer
A lightweight, durable, microwave spectrum analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.
-
Product
Micro Power or Micro Coax, SIM Insert, ITA, 26 GHz, 2 POS, 6 Slot (not loaded)
510181110
SIM Insert
Micro Power or Micro Coax, SIM Insert, ITA, 26 GHz, 2 POS, 6 Slot (not loaded)Micro Power or Micro Coax patchcords need to be purchased separately.
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 50 GHz, 50 Ω, SMA-2.4, Failsafe, Remote Mount
42-782B-551-E
Switch Module
The 40-782B-551-E (PXI) and 42-782B-551-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
SMARC V2.0 SoM With I.MX8M Quad/Dual 1.5 GHz/1.3 GHz (Industrial) SoC, 4GB RAM, 64GB EMMC, CAN, MIPI CSI/DSI And HDMI 2.0
SCM180
-
The SCM180 is a SMARC v2.0 system on module with a choice of quad- or dual-core Arm® Cortex®-A53 processors. The ultra low power, high performance, RISC-based module measures only 82 x 50 mm and utilizes the powerful i.MX 8M processor. Its scalability, optimized pinout schematic and low profile design offers high level of versatility to help system integrators drive their important projects forward. The SCM180 is unique among other SMARC modules of its kind because it features Trusted Platform Module (TPM) for optimum security. With a discrete, dedicated microcontroller designed to support hardware encryption and decryption, the SCM180 delivers enhanced security for an added layer of protection. It also offers a choice of operating temperature ranges and can operate reliably in harsh environments. The SCM180 is suitable for a wide range of smart, portable/mobile-integrated IoT applications including robotics, automotive, factory automation, smart agriculture, casino gaming, medical, retail, surveillance and more. With its NXP artificial intelligence core technologies-enabled capabilities, the SMARC module can be programmed to support smart automation and machine-learning application requirements.
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
40-782B-542-E
Switch Module
The 40-782B-542-E (PXI) and 42-782B-542-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
Product
PXI/PXIe Microwave Relay, Quad SPDT, 67 GHz, 50 Ω, SMA-1.85, Failsafe
42-780B-574
Relay
The 40-780B-574 (PXI) and 42-780B-574 (PXIe) are quad failsafe SPDT 67 GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
Product
Comb Generator, 10 MHz to 67 GHz
U9391G
-
The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
Product
1.5 GHz, 1 MΩ, 0.9 pF Active Probe
ZS1500
-
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1500 is ideal for 1 GHz and lower oscilloscopes.
-
Product
InfiniiMax II Series Probe Amplifier, 12 GHz
1169B
Amplifier
Provides a large common mode range and a large offset range for measuring differential and single-ended signals.
-
Product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (f)
CK058F
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Coaxial Fixed Attenuator, DC to 12.4 GHz
8493A
Attenuator
The Keysight 8493A coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range at a low price. The attenuator is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 30 dB. This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.
-
Product
PXIe Performance Vector Signal Analyzer: 50 GHz
M9393A
Vector Network Analyzer
9 kHz to 8.4 GHz, 14 GHz, 18 GHz, or 27 GHz Frequency extension to 50 GHz (minimum frequency of 3.6 GHz) with Option FRX40 MHz (standard), 100 MHz, or 160 MHz analysis bandwidth, and optional wideband IF output with Option WB1Up to 4 time-synchronous channels
-
Product
RF Wideband Downconverter Solution From 100 KHz To 8 GHz
DC8G100
-
GaGe wideband downconverters are wide frequency coverage receivers that feature a single RF input and 3 standard software selectable IF bandwidths, from 10 MHz to 100 MHz, or 3 optional software selectable IF bandwidths, from10 MHz to 160 MHz. The carrier center frequencies can be tuned from 50 MHz to 27 GHz, using direct digitization below 50 MHz.
-
Product
2X8 USB Solid State Switch Matrix, 300 KHz To 9 GHz
P9165B
Switch Module
P9165B 2X8 USB solid state switch matrix, 300 KHz to 9 GHz is a full cross-bar switch matrix that provides a switch based multiport VNA solution in the form of compact USB controlled involving larger scale of multi-DUT or multiport measurements such as 5G massive MIMO antenna measurement and others.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP8T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-788-022-E
Multiplexer Module
The 40-788-022-E (PXI) and 42-788-022-E (PXIe) are dual failsafe SP8T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXIe Microwave Multiplexer, Single SP4T, 26.5 GHz, 50 Ω, SMA, Failsafe
42-785C-431
Microwave Multiplexer
The 40-785C-431 (PXI) and 42-785C-431 (PXIe) are single failsafe SP4T 26.5 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PNA-X Microwave Network Analyzer, 13.5 GHz
N5241B
Network Analyzer
Simplify your test stations by replacing racks and stacks of equipment Increase productivity with the most integrated and flexible single-connection microwave test engine Reduce test time with the world's widest range of single-connection measurement applications Accurately test linear and nonlinear device characterization using advanced error correction Accelerate insight into component behavior using a multi-touch display and intuitive user interface Every spec verified, adjustments included Lock in support & peak performance from the start
-
Product
10 MHz – 6 GHz USB Power Sensor
U2001B
Power Sensor
U2001B USB power sensor measures average power over the frequency range 10 MHz to 6 GHz and power range -30 dBm to +44 dBm.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 50 GHz, 50 Ω, SMA-2.4, Remote Mount, Failsafe
42-785C-452-E
Multiplexer Module
The 40-785C-452-E (PXI) and 42-785C-452-E (PXIe) are dual failsafe SP4T 50 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
1-Chan 3.6 GHz or 2-Chan 1.8 GHz 12-bit A/D with Virtex-6 FPGA - 3U VPX
Model 52640
-
- Ideal radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- One-channel mode with 3.6 GHz, 12-bit A/D- Two-channel mode with 1.8 GHz, 12-bit A/Ds- 2 GB of DDR3 SDRAM- Sync bus for multiboard synchronization- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Terminated, Failsafe
40-785C-471-TE
Multiplexer Module
The 40-785C-471-TE (PXI) and 42-785C-471-TE (PXIe) are single failsafe SP4T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 67 GHz, 50 Ω, SMA-1.85, Terminated, Remote Mount, Failsafe
40-785C-573-TE
Multiplexer Module
The 40-785C-573-TE (PXI) and 42-785C-573-TE (PXIe) are triple failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
4-Port Coaxial Switch, DC to 26.5 GHz
8763C
-
The Keysight 8763C offers excellent electrical and mechanical performance with broadband operation, high isolation, low SWR, long life, and exceptional repeatability.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 18 GHz, 50 Ω, SMA, Failsafe
42-784B-021
Multiplexer Module
The 40-784B-021 (PXI) and 42-784B-021 (PXIe) are single failsafe SP6T 18 GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
FieldFox Handheld Microwave Spectrum Analyzer, 18 GHz
N9937B
Spectrum Analyzer
A lightweight, durable, microwave spectrum analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.





























