GHz Synthesizers
See Also: GHz
-
Product
Streamline Vector Network Analyzer, 9 KHz To 4.5 GHz, 2-port
P9370B
-
Compact, faceless, vector network analyzer (VNA). Affordable full two-port VNA which dramatically reduces your size of test. Up to 4.5 GHz.
-
Product
PXI-2556, 2.5 GHz, 75 Ω, Dual 4x1 PXI RF Multiplexer Switch Module
778572-56
-
2.5 GHz, 75 Ω, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2556 is an RF signal multiplexer switch module. The multi-bank architecture of the NI PXI‑2556 makes it ideal for test systems that require parallel operations such as the stimulus/response testing of video RF devices such as tuners. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
-
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 40 GHz, 50 Ω, SMA 2.9, Terminated
42-788-051-T
-
The 40-788-051-T (PXI) and 42-788-051-T (PXIe) are single SP8T 40 GHz microwave multiplexers with automatic termination of unused signals.
-
Product
Manual Step Attenuator, DC to 26.5 GHz, 0 to 70 dB, 10 dB steps
8495D
-
The Keysight 8495D dc to 26.5 GHz manual step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 10 dB steps from 0 to 70 dB. Precision gold-plated leaf springs ensure long life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.
-
Product
PXIe-5162, 1.5 GHz, 5 GS/s, w/o CableSense, 10-Bit PXI Oscilloscope
782622-06
-
PXIe, 1.5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope—The PXIe-5162 high-speed oscilloscope device has two or four channels that sample at up to 5 GS/s with flexible settings for coupling, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require up to 1.5 GHz of analog bandwidth and flexible measurement configurations.
-
Product
2X8 PXIe Switch Matrix, 300 KHz to 6.5 GHz
M9165A
-
M9165A 2X8 PXIe switch matrix, 300 KHz to 6.5 GHz is a full cross-bar switch matrix that provide a switch based multiport VNA solution.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
-
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Streamline Vector Network Analyzer, 9 KHz To 6.5 GHz, 4 Or 6-port
P5021B
-
Compact, faceless, vector network analyzer (VNA). Flexible four or six-port VNA dramatically reduces your size of test. Up to 6.5 GHz.
-
Product
PXIe Vector Network Analyzer, 300 kHz to 26.5 GHz
M9375A
-
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
Product
Oscilloscope 59 GHz, 2 Channels
UXR0592B
-
The UXR0592B is the 59 GHz, 2 channel, Infiniium UXR-Series real-time oscilloscope.
-
Product
2 To 18 GHz 6 Channel Downconverter
-
Teledyne RF & Micrrowave's Six Channel 2 - 18 GHz (RF and LO) downconverter operates with an IF of ~960 MHz, providing 25 dB of RF-IF gain, and bandwidth of ~500 MHz. This downconverter operates on a single LO at -6 dBm which is amplified, split, then again amplified to each of the 6 channels. Integrated into each channel is a range extension switch, controlled by a TTL input and adding 20 dB attenuation. Noise figure is ~ 13.5 dB and output IP3 is ~+25 dBm. The downconverter is 2- sided, hermetically sealed and designed for rugged applications.
-
Product
Coaxial Termination, DC to 26.5 GHz
909D
-
The Keysight 909D is a precision, low-reflection dc to 26.5 GHz load for terminating a 50-ohm coaxial system in its characteristic impedance. It is intended for use as a calibration standard.
-
Product
Streamline Vector Network Analyzer, 9 KHz To 20 GHz, 4-port
P9384B
-
Compact, faceless, vector network analyzer (VNA). Affordable full 4-port VNA which dramatically reduces your size of test. Up to 20 GHz.
-
Product
Infiniium UXR-Series Oscilloscope: 70 GHz, 4 Channels
UXR0704A
-
The UXR0704A is the 70 GHz, 4 channel, Infiniium UXR-Series real-time oscilloscope
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 50 GHz, 50 Ω, SMA-2.4, Failsafe
42-785C-551
-
The 40-785C-551 (PXI) and 42-785C-551 (PXIe) are single failsafe SP6T 50 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Infiniium UXR-Series Oscilloscope: 13 GHz, 4 Channels
UXR0134A
-
The UXR0134A is the 13 GHz, 4 channel, Infiniium UXR-Series real-time oscilloscope.
-
Product
PXI-2559, 2.5 GHz, 75 Ω, Dual-Terminated SPDT PXI RF Relay Module
778572-59
-
2.5 GHz, 75 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2559 is a general-purpose switch module featuring two independently terminated single‑pole double‑throw (SPDT) relays. You can use it to add flexibility to your video switch network or to maintain uniform signal paths across multiple channels when building high-channel-count multiplexers. The PXI‑2559 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX02
-
The N5293AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 110 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
Infiniium UXR-Series Oscilloscope: 5 GHz, 1 Channels, 1mm Inputs
UXR0051AP
-
The UXR0051AP is the 5 GHz, 1 channel, 1mm input, Infiniium UXR-Series real-time oscilloscope.
-
Product
S-band Klystron 2.856 GHz / 6 MW
-
Insight Product Co. 's S-band, 2.856 GHz, klystron provides up to 6.0 MW of output pulse power, and has two regimes of operation.
-
Product
FieldFox Handheld Microwave Analyzer, 18 GHz
N9917B
-
Keysight's FieldFox portable analyzers are equipped to handle your toughest working environments during routine maintenance, in-depth troubleshooting, and anything in between.
-
Product
50 MHz to 40 GHz USB Peak and Average Power Sensor
U2022XA
-
Keysight U2020 X-series USB power sensors provides the peak and average power measurement capability of a power meter in a compact and portable form factor.
-
Product
Power Divider, DC to 26.5 GHz
11636B
-
The Keysight 11636B is a dc to 26.5 GHz power divider for direct power dividing applications. The excellent impedance match of all three ports improves fault location measurements by reducing re-reflections. The Keysight 11636B power divider/combiner is recommended when making wideband comparison measurements with the Keysight 8757 scalar vector network analyzer.
-
Product
Keysight Streamline USB Vector Network Analyzer, 4.5 GHz
P9375A
-
Compact, faceless, USB vector network analyzer (VNA). Affordable full two-port VNA which dramatically reduces your size of test. Up to 26.5 GHz.
-
Product
Low-Barrier Schottky Diode Detector, 0.01 to 18 GHz
33330B
-
The Keysight 33330B low-barrier schottky diode detector has been widely used for many years in a variety of applications including leveling and power sensing. It offers good performance and ruggedness. Matched pairs (Option 001) offer very good detector tracking.
-
Product
1 GHz A/D and D/A with Virtex-6 FPGA - XMC
Model 71630
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- One 1 GHz 12-bit A/D- One 1 GHz 16-bit D/A- Up to 2 GB of DDR3 SDRAM or 32 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- Front panel clock/sync bus for multimodule synchronizationPCI Express (Gen. 1 & 2) interface up to x8 wide- Optional user configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Synchronize up to four modules with Model 7192 System Synchronization and Distribution Amplifier - PMC/XMC- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount
-
Product
Spectrum Analysis, Up To 50 GHz
S930905B
-
The S930905B spectrum analysis adds high-performance microwave spectrum analysis to the N522xB/N523xB/N524xB PNA network analyzer family up to 50 GHz.





























