Calibration References
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
-
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
-
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
-
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Electronic Calibration Module (ECal), 40 GHz, 2.92 Mm, 2-port
N4692D
-
The Keysight N4692D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4692D is a precision 2-port ECal module that supports 2.92 mm connectors up to 40 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4692D is included for securing your ECal module and accessories.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz, Type-N(m), 50 Ohm
85514A
-
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
Product
10-meter (33 feet) Sensor Cable
E1739B
-
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
-
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Linear/Angular Measurement Kit
55281B
-
The Keysight 55281B Linear/Angular Measurement Kit is part of the Keysight 5530 Laser Calibration System and enables the system to measure both linear velocity along a machine's travel path as well as rotation about an axis perpendicular to the axis of motion (pitch and yaw).
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
-
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Linear Measurement Kit
55280B
-
The Keysight 55280B Linear Measurement Kit is part of the 5530 Laser Calibration System and enables the system to measure linear displacement and velocity along a machine's travel path. The purpose of this measurement is to document capability and, when possible, improve positioning accuracy along an axis for any machine that requires positioning accuracy and velocity control.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
-
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
-
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
-
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
-
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Electronic Calibration Module (ECal), 18 GHz, Type-N, 50 Ohm, 2-port
N4690D
-
The Keysight N4690D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4690D is a precision 2-port ECal module that supports 50-ohm type-N connectors up to 18 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4690D is included for securing your ECal module and accessories.
-
Product
RTC Reference Temperature Calibrator
-
AMETEK Sensors, Test & Calibration
Our most advanced and accurate portable temperature calibrator with the widest available temperature range. One of its great features is the patented DLC system for perfect temperature uniformity in the insert – even when calibrating large sensors or many sensors at a time.
-
Product
7-Meter Laser Head Cable
10882B
-
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Reference Meters
-
Whether standard or high precision, ThermoWorks handheld meters feature rugged housing and best-in class accuracy across a variety of temperature ranges. Choose from integrated systems or meters that accept multiple probes, single or dual channel meters, alarms or reference models. Perfect for BBQ or sous-vide applications, dairy processing and meat processing, pharmaceutical labs, concrete curing, health departments, and for line checks, critical control point management, and HACCP checklists.
-
Product
Reference Antennas
Type NRD
-
Reference antennas are precision dipole antennas that offer a fixed 2.15 dB of gain over an isotropic antenna along the major lobe axis at specified frequencies (2.15 dBi). They are intended to be used for antenna field pattern and gain measurements, or general RF sensing in the laboratory.
-
Product
Reference Magnet
-
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
-
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Reference Standard
-
Beijing GFUVE Electronics Co.,Ltd.
It has been designed for universal laboratory and test applications and is intended for checking and the calibration of reference standards for electrical power and energy.
-
Product
Calibration
EMC Test Antennas
-
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
Product
RF Reference Sources
-
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
Calibrators
-
Our high accuracy calibrators work with all competitor products and offers the customer a way to maintain their equipment, while keeping the specifications of their process.
-
Product
RF Reference Source
96040A Series
-
The 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.
-
Product
Reference Cells
-
Reference cell is used for measuring and setting the intensity of solar simulators for one sun (or other user desired) intensity condition. They are also used to calibrate the IV Measurement system photo-detector intensity to match the measured ISC to calibrated ISC.