Earth Leakage Breaker
-
Product
Digital Earth Resistance Testers
ST-1520
-
Capable of measuring earth voltage.2mA measuring current permits the testing of earth resistance without tripping earth leakage current circuit breakers in the circuit.Auto power off function.The timer operates automatically for approximately three to five minutes when the "push button switch" and "timer on button" are pressed together.
-
Product
Digital Earth Resistance Tester
8PK-ST1520
-
Capable of measuring earth voltage (Vac.) 2mA measuring current permits earth resistance to test without tripping earth leakage current breakers in the circuit. Battery operated. Auto power off function. Data hold function. Small and light weight.
-
Product
Measuring Display Unit Breakers
-
Mitsubishi Electric Automation, Inc
Measuring display units (MDU) are integrated with molded-case circuit breakers and earth leakage circuit breakers for measuring, displaying, and transmitting information on cable ways. This display unit closely monitors energy consumption by measuring current, voltage, power, electric energy, harmonic current, leakage current and power factor.
-
Product
Earth Leakage Breaker And Residual Current Device
IGR Series
-
IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.
-
Product
Earth Leakage
-
National Meter Industries Inc.
This new range features a series of improvements intended in particular for installing unitson switchboards. Along with the usual attachment elements, this unit can be installed onDIN rails using an accessory, which facilitates its installation.
-
Product
Earth Leakage
-
Earth leakage is when the current flowing in a system finds an alternative return path other than active and neutral conductors.
-
Product
DC/AC Earth Leakage Current Measurement
FDAZCT-11L-0.4
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Bipolar ±15V Power Supply.*Output ±5V at primary nominal current.*Applicable Frequency DC-18kHz.*Inside Diameter:φ11mm
-
Product
Circuit Breakers
-
As the premier supplier of power system components, Interpower has what you need to complete your projects, including circuit breakers. Interpower has no minimum order requirements, plus same day shipping is available on in-stock Interpower products.
-
Product
Neutral Earthing
International Standards
-
NERs may only be called upon to operate a few times in their service life, which may be 25 years or more. Reliability is imperative, and has been proved over many years in electric traction rolling stock and under conditions of severe vibration and extreme climate world-wide.
-
Product
Earth resistance meters
-
The PROMAX earth meters guarantee the proper operation of industrial and home electrical circuits.
-
Product
Earth Resistance Tester
G-TEST
-
To check the condition of a grounding connection, an earthresistance tester is used to measure the residual ground voltage,resistance and resistivity (Wenner method).
-
Product
Air Circuit Breakers
-
Mitsubishi Electric Automation, Inc
Low-voltage air circuit breakers (ACB) can be used as the main circuit breakers of power distribution systems in buildings, factories and ships. The AE-SW series offers a "fixed" type or "drawout" type option. This ACB series ranges from 630 amps to 6300 amps and provides high-level circuit monitoring as well as friendly networking capablities for a wide range of applications.
-
Product
Circuit Breaker Analysis Systems
-
When a fault such as a short circuit or current overload is detected by a protective relay, a trip impulse is sent to the circuit breaker. The circuit breaker must function as specified and interrupt the current as soon as possible or severe damage may occur. The damage caused by a malfunctioning circuit breaker can often be catastrophic, resulting in significant damage to the electrical system.
-
Product
Non-Trip Earth Resistance Measurement
M73
-
M73 has been developed for operators who mainly work on private installations. M73 is very easy to use, it is very small in size and it carries out all necessary tests to establish COMPLIANCE (and hence ensure SAFETY) of an electric system.
-
Product
Locomotive Circuit Breaker Analyser
CBScan Locomotive Circuit Breaker
-
CBScan Locomotive Circuit Breaker Analyser is a compact and portable analyser used for testing 25 kV medium voltage circuit breakers that are used in electric locomotives for protection from the frequently occurring short-circuits in the overhead catenary system. The analyser is ideal for railway yards for performing periodic maintenance checks.
-
Product
Automated Leakage Current Tester
LINECHEK® II Series
-
Our LINECHEK II Leakage Current Tester is designed for medical device manufacturers. With a feature set built around maximizing the efficiency of the Leakage Current test, LINECHEK II satisfies medical application requirements demanding up to 40 Amps of continuous line current. Use it on the bench or in a rack, from the front panel or via a PC interface to ensure your medical device is ready for global deployment.
-
Product
Circuit Breaker Test Equipment
-
Providing the in-depth analysis to ensure effective maintenance maximum reliability.
-
Product
Earth Ground Clamp Meter
T2000
-
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)
-
Product
Circuit Breaker Testing
-
Weshine Electric Manufacturing Co., Ltd
Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.
-
Product
Earth Resistance Tester
-
PeakTech Prüf- und Messtechnik GmbH
A Rugged sealed digital earth tester is built with all the protection you need for outdoor use. The instrument is suitable for the testing of single earth electrodes such as lightning conductors and other small earthing systems according to VDE 0413. The resistance of conductors such as continuity and conduit coupling joints can also be measured. Two-terminal operation measurement, which reduces the accuracy, can also be done by shorting P and C terminals. It has an advanced circuit design that permits the instrument to operate with the minimum influence from earth voltage and earth resistance of the auxiliary spikes.
-
Product
Digital Earth Tester
-
Cambridge Instruments & Engineering Co.
'CIE' Digital Earth Resistance Tester is designed to measure the resistance if earth used in power circuit, Telecommunications, Railway Electrification, Domestic and Industrial electrical installations. The tester measures directly the resistance of the earth and also measure the ground resistivity.
-
Product
Circuit Breakers for Equipment
-
Mitsubishi Electric Automation, Inc
The optimum circuit breaker for opening/closing power sources and preventing overload and short-circuit conditions in control circuits of automation applications, construction equipment, office machines, communications and measurement devices.
-
Product
Earth Tester
TAURUS PRECIOHM ET
-
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
Product
Stationary Circuit Breaker Test System
ACTAS C160
-
Stationary test system for carrying out fully automatic final factory tests, type and function tests on all kinds of switchgear devices, such as circuit breakers, disconnectors or earthing switches, regardless of the type of drive unit. All the electrical and mechanical parameters needed for the assessment of switching performance are measured in real time and evaluated without either the main contact chambers or the drive unit having to be opened. The system has analog and incremental input channels for the acquisition of analog quantities.
-
Product
Circuit Breaker Testing
ACTAS
-
Portable and stationary test systems for performing fully automatic function tests on all types of switchgear devices, including the drive units of switch bays. ACTAS test systems provide precise information as to the condition of the chamber and drive unit without requiring them to be opened. The sheer number of parameters to be determined, the wide variety of different types of switchgear equipment in use and the harsh environmental conditions encountered during on-site tests place extreme demands on test equipment.
-
Product
Earth Fault Detector
K-3838
-
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
Product
System Grounding & Earthing Analysis
-
ETAP's system grounding & earthing foundation automatically detects the system earthing configuration based on source and transformer grounding or earthing type selection. The resulting earthing types are displayed both on the one line diagram and for the various connected cables.
-
Product
Portable Circuit Breaker Tester
PI-1600
-
The PI-1600 Circuit Breaker Tester incorporates modular design and flexibility to provide unequaled capability in a portable package. The PI-1600 test set is two testers in one, incorporating the PI-800 and PI-AUX. The PI-800 section can be used alone, on 120 or 240 VAC supplies, generating continuous current of 400, 800, amps at 4.2 kVA, with peak output to over 10x. When configured for the PI-1600, the PI-AUX output unit is connected in series or parallel to the PI-800. The PI-AUX boosts total power to 9.8KVA, and allows testing of draw-out breakers and MCB’s to 1600 Amps. The units are housed in rugged interlocking suitcase-size enclosures. Each piece weighs no more than 125 pounds, allowing one-person hand truck mobility. Basic operation is very simple, and the proven MAC-21 control instrumentation provides optimal output control and measurement. The MAC-21 instrumentation is supplied in a separate rugged portable case, interlocks on top of the PI-800, and connects to a cable in the rear of the test set.
-
Product
Magnetic Flux Leakage Testing
-
PRÜFTECHNIK Condition Monitoring GmbH
NOVAFLUX - Flux Leakage Inspection for Black or Bright Steel Bars
-
Product
DC Magnetic Flux Leakage Testing
ROTOMAT / TRANSOMAT Product Family
-
Foerster Instruments, Incorporated
With the new generation ROTOMAT DA and TRANSOMAT DA flux leakage test systems FOERSTER is setting new standards in continuous quality assurance of ferromagnetic steel tubes. The test systems enable the reliable detection of natural and oblique defects, regardless of their angle or length, in addition to standardized longitudinal and transversal defects. The miniaturization of sensors together with highly integrated electronic components dramatically increases the number of channels. This makes a more precise and finer scan of the surface possible, giving a more complete set of information regarding detected defects. The newly introduced C-Scan visualizes these defects in high-definition and real-time, resulting in a completely new evaluation of the tubes to meet rising quality requirements.