Pre-amplifiers
Detect and strengthen a signal prior to greater amplification.
-
Product
X-Ray Preamplifier Power Supply
-
The X-ray Preamplifier Power Supply (XPPS) provides power for 50 or more preamplifiers. The 19-inch rack-mount or benchtop unit contains linear power supplies that generate +/-12V @ 5.1 Amperes and +/-24V @ 3.6 Amperes, with very little noise.
-
Product
1 MHz Bandwidth Voltage Preamplifier with Bandpass Filter
EC6081 mk2 - preamplifier
-
The EC6081 mk2 (VP2000) is a 1MHz bandwidth voltage preamplifier with bandpass filter that is designed for uses in conjunction with piezoelectric hydrophones. VP2000 offers excellent low-noise performance over the entire frequency range; and adjustable gain selection. A range of 12 high-pass and 12 low-pass filters are available, these allow ideal band pass filter settings.
-
Product
DryLoc pH/ORP Preamplifier and Connectors
2760
-
The 2760 preamplifier allows any DryLoc pH/ORP electrode to work with Signet ProcessPro and ProPoint pH/ORP instruments. It is also sold as a simple connector for use with other manufacturers' instruments that do not require a preamplified signal.
-
Product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783124-01
-
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
Product
Ultra Low Noise Preamp
J2180A
-
The J2180A low noise preamplifier provides a fixed, AC coupled 20dB gain while converting a 1 MOhm input impedance to a 50 Ohm output impedance. With a 3dB bandwidth of 0.1Hz to 100MHz, the preamplifier improves the sensitivity of oscilloscopes, network analyzers and spectrum analyzers while reducing the effective noise floor and spurious response. The preamplifier can also serve as a low frequency DC blocker for a spectrum analyzer or you can use it to connect a high input impedance oscilloscope probe to 50 Ohm equipment.
-
Product
Breakout Module
PXI-PDM
-
The PXI Preamplifier Power and Trigger Breakout Module (PXI PDM) is an accessory for the Pixie-4 system.
-
Product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783156-01
-
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
Product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783124-02
-
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR … test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
Product
USB Preamplifier, 100 MHz to 26.5 GHz
U7227C
-
The U7227C, 100 MHz to 26.5 GHz USB preamplifier is designed to bring reliable gain and low noise figure to measurement systems improving the overall system performance and reduce systematic errors; a total solution to the X-Series signal analyzers to perform noise figure measurement
-
Product
ICP Microphone System
HT378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Noise Figure Analyzer, Multi-touch, 10 MHz to 40 GHz
N8976B
-
The N8976B high performance noise figure analyzer is designed to make fast, accurate and repeatable noise figure measurements. When paired with an SNS Series noise source and U7227 Series USB preamplifier the ENR data from the SNS and USB preamplifier data automatically downloads into the N8976B.
-
Product
Low Noise Preamplifier
-
The UPL-3001 preamplifier is a high performance solution for the low-noise amplification of ultrasonic signals. Designed for signals ranging from 0.5 to 300 MHz, the small and lightweight, rugged unit is perfect for remote applications. This is ideal for P&C, TT, AUT or TOFD inspection.
-
Product
Power Probes
RkP-400 Series
-
The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
Product
Precision Current Preamplifier
SIM918
-
Stanford Research Systems, Inc.
The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled.
-
Product
High Impedance Preamplifier
1671
-
The Model 1671 is a single ended low noise field effect transistor
-
Product
Shield Level / Pathloss Equipment
SG1000B/PR1000A
-
The SG1000 Signal Generator and PR1000A Preamplifier have been designed to simplify the measurement of shielding integrity in a shielded enclosure. When coupled with a high stability spectrum analyzer and an appropriate selection of test antennas, the SG1000/PR1000A combination can measure shielding effectiveness at all of the NSA 94-106 (supersedes NSA 65-6) defined test frequencies from 1 kHz to 10 GHz.The PR1000A amplifies the received signal from the test antenna and overcomes the high noise figure of the companion test receiver or spectrum analyzer. The PR1000A will ensure that the system noise figure will be less than 4.5 dB at all test frequencies from 1 kHz to 10 GHz. When used with a spectrum analyzer measurement bandwidth of 100 Hz, the system exhibits a sensitivity of -150 dBm at the test antenna output.To overcome high cable loss between the test antenna and the PR1000A assembly at 10 GHz, a remote low noise pre-amplifier (Praxsym PN 310-010091-001) is mounted directly onto the 10 GHz antenna.
-
Product
Preamplifier
-
The UBBV series are external, extremely low-noise broadband preamplifiers that can be mounted to any SPECTRAN spectrum analyzer. They are ideally suited for spectrum analyzers and oscilloscopes as well as antennas of all manufacturers and are supplied with extensive accessories.
-
Product
ProBus Probe Adapter for TekProbe-BNC Probes
TPA10
-
- Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes
-
Product
RX Pre-Amplifier System
RAM-34
-
The RAM-34 is a complete pre-amplifier system designed primarily for the low bands 160M thru 40M. It has inputs for four receive antennas and internal 3-pole bandpass filters for 160M, 80M and 40M. In addition to the pre-amplifier, it has a step attenuator that togetherwith the amplifier stage provides gains from -20 dB to +20 dB in 5 dB steps. This allows equalizing the signal levels between the antenna inputs. Gain settings are memorized for each antenna on each band. Different types of receive antennas have different signal levels and the gain memories eliminate the need to adjust the receiver or pre-amplifier when switching between the antennas.
-
Product
Low Noise Voltage Preamplifier
1201
-
The Model 1201 Voltage Preamplifier with Remote Gain Programming Option (06) is usable in both computer controlled and maual applications requiring uncompromising performance.
-
Product
PXIe-5668, Up to 26.5 GHz PXI Vector Signal Analyzer
783156-02
-
Up to 26.5 GHz PXI Vector Signal Analyzer - The PXIe‑5668 offers wide bandwidth with high-performance measurement performance and speed. It meets the challenging requirements of applications such as wireless communications, radio frequency integrated circuit characterization, RADAR test, and spectrum monitoring and signal intelligence. With its implementation as a PXI instrument, the PXIe‑5668 also features the fast measurement speed required for high-volume manufacturing test, and multi-instrument synchronization capabilities for phase-coherent MIMO test. You can use the optionally included PXIe-5698 preamplifier to improve dynamic range and sensitivity near the instrument noise floor.
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
(40×70×12mm) Full Function Single Channel Small Form Factor Pre-Amplifier EDFA Module
SPA4300-FM01
-
Hangzhou Huatai Optic Tech. Co., Ltd.
SPA4300-FM01 is a full-function single channel Pre-Amplifier EDFA module with digital control electronics, adopts subminiature 40×70×12mm compact package, combined with artistic package and best optic performance, creating the best flexible and variable low-cost amplifier in the market. This module is suitable for multiple network application, especially the application that requires 40GB/S transmission speed.
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
External Pre-amplifiers
-
Although all Spectrum A/D cards have a very powerful input section with a highly configurable input amplifier and a variety of input ranges it is sometimes necessary to have additional external amplifiers if the signal to acquire has an extremely low level. Spectrum offers a range of perfectly matching external amplifiers to cover such cases. These powerful amplifiers have been rated using the Spectrum cards and offer best performance together with high amplification rates.The amplifiers are simply connected between the signal source and the Spectrum A/D card input and can be manually switched between different settings using small lever keys. All amplifiers allow the offset compensation by using an adjustable screw.
-
Product
Bias Tees for Radio Amateurs
-
Bias Tee for remote power supply of preamplifiers and converters via the coaxial cable.
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
Product
Probes For Non-Contact Ultrasonic Testing
SONOSCAN CFC / CF
-
Due to the strong damping properties of air, low frequencies in the kHz range are used in air-coupled ultrasonic testing. It is therefore all the more important that the ultrasonic transducers offer a particularly high sensitivity in order to ensure high penetration and improved resolution. We achieve this, among other things, by installing preamplifiers in the receiver probe as well as by using our own Piezocomposite Technology, which enables a flexible use of the matching materials in our CFC and CF probes.
-
Product
Microphone Preamplifier
426A05
-
Preamplifier for 1/4" side vented prepolarized microphones.
-
Product
Preamplifier, 10 MHz to 4 GHz
87405B
-
Preamplifiers and System Noise Figure Application Note This note discusses noise figure basics including applications and characteristics of Keysight simplifier technology. Highlighted are Keysight's 87405C portable preamplifiers that provide an exceptional gain of 25 dB up to 18 GHz and a probe-power bias connection which eliminates the need for an additional DC power supply. Read the Preamplifiers and System Noise Figure Application Note now!





























