Voltage Standards
-
Product
Voltage Control Phase Shifter
-
RF Lambda’s voltage control phase shifters use an analog control voltage to vary the phase of an RF signal. They are available in a variety of frequencies and overall phase shift ranges. Hermetically sealed options are available upon request.
-
Product
High Voltage Test & Measurement
-
High-voltage (HV) testing utilizes the phenomena in electrical insulations under the influence of the electric field for the definition of test procedures and acceptance criteria.
-
Product
Raptor HV High Voltage Tester
-
The Raptor-HV, also called the high voltage slave, is an optional product that extends the Raptor’s applications to tests that require the use of a moderately high AC voltage.
-
Product
High Voltage 50 Ω Pulse Generator
TLP-8010C
-
High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
Product
DC High Voltage Test Set
-
It is extensively used in electrical and power generation industry for varied testing operations.
-
Product
Eight-channel USB Voltage and Thermocouple DAQ
Model DI-2008
-
Includes DI-2008 instrument, WinDaq software, calibration certificate, terminal screwdriver, and USB cable (6-feet). Eight differential and isolated analog input channels. Seven bi-directional digital input ports, including: Counter input for totalizing applications, Rate input for frequency/flow/rpm applications. ChannelStretch™ channel expansion to 128 analog and 112 digital channels. Programmable voltage and thermocouple measurements per channel. 10 mV to 50 V programmable range per channel in 12 steps.
-
Product
Surge Voltage and Surge Current Testing Systems
-
HIGHVOLT Prüftechnik Dresden GmbH
Pulse Voltage Test Systems are used for surge testing on transformers, cables, gas insulated switchgear (GIS), arresters, and other high voltage equipment.
-
Product
Standard Precision GNSS Module
AIW-210
-
M.2 2242 Key B form factorStandard Precision GNSS L1 band92 channel support u-blox NEO-M9N engine (GPS, GLONASS, BeiDou, Galileo, QZSS andSBAS)Open sky cold start 24 second / Aided starts 2 secondUSB 2.0 communication interfaceAccuracy 2.0m CEPOperating temperature: -40°C ~ +85°C / -40°F ~ 185°F
-
Product
Standard Probe Station Chucks & Accessories
-
In this test solutions section of our website we describe the expanding line of Abet PV IV probe stations for the growing variety of solar cell types and sizes being developed around the world. This page describes a line of vacuum chucks and accessories for top/bottom, top/top, and bottom/bottom solar cells from 3 x 3 mm to 300 x 300 mm. Probe stations for multiple device on a single substrate and multifunction probe stations are described further in the sections highlighted to the left of this page.
-
Product
Standard Current Transformers
-
Measurements International Ltd.
Single Range, Highest Permeability, Wide Measurement Range, Negligible Current Errors, High Accuracy.
-
Product
PC Controlled Low Voltage Testers
-
PC Based Testers Low Voltage Introduction. The PC based analyzers provide high-speed testing for wire harnesses, backplanes, and printed-circuit boards.
-
Product
Individual UPC Bar Code Standards
-
The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)
-
Product
Cycle Voltage Drop (Rise) Simulator
STT-CSS-20P1
-
Beijing KeHuan Century EMC Technology Co,.LTD
*Using 2 The regulator, and the rated voltage adjustable automatic voltage regulator, power fluctuations avoid adversely affecting the test results. Simulate the test under 110V power supply. It can simulate the fluctuation of the power grid under extreme conditions (such as high or low power supply voltage in remote areas).
-
Product
Voltage Tester, 90V to 1000V
72-10385
-
Non Contact AC Voltage Detector with Vibrating Alert The easy to use AC Voltage Detector provides site, sound, and vibration indication for added safety in even bright or noisy environments. Flashing, beeper, and vibrating indicators to alert use of AC voltage.
-
Product
Standard 0.83 (23.50) - 2.85 (80.80) Battery Probe
CCA-004
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 470Overall Length (mm): 11.94
-
Product
High Voltage Probe
HVP-40DM
-
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
Product
High Speed High Voltage Amplifier
WMA-300
-
The WMA-300 is a high voltage, wide bandwidth laboratory amplifier. Its high output voltage, current and wide bandwidth have been designed to serve the needs of a wide variety of high-tech experiments. The WMA-300 can be used for MEMS actuation, EO-modulators, PZT (piezo) positioners, ultrasonics, and many other applications. Two WMA-300 amplifiers and a WMA-IB-HS phase inverter - buffer can be used to double the output voltage.
-
Product
Standard 0.88 (24.90) - 4.50 (128.00) Switch Probe
SSP-5C
Switch Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Spring Force Remark: Force at switch point: 2.36 (66)Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 150Full Travel (mm): 3.81Recommended Travel (mil): 100Recommended Travel (mm): 2.54Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,210Overall Length (mm): 30.73Switch Point (mil): 25Switch Point (mm): 0.64
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3B
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
NanoLattice Pitch Standard (NLSM)
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
Product
LXI High Voltage Switching Multiplexer Plugin Module
65-231-702-HI
Multiplexer Module
The 65-231-702-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 7 kV. Multiplexers are created by populating the 65-200-002 scalable chassis with multiplexer plug-in modules that provide access to the Channel and Common signals on 51-pin front panel connectors. Users can specify as many or as few plug-in modules as they require and can field upgrade the chassis to extend the multiplexer.
-
Product
Three Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
Product
Voltage Sag Generator
SKS-1120GTB
-
Shanghai Sanki Electronic Industries Co., Ltd.
The cycle drop simulator is used to reproduce the voltage fluctuation phenomenon of commercial power supplies. Simulate the grid voltage drop and short-term interruption caused by the accident or the sudden change of the large load in the low-voltage power grid, or the grid voltage change caused by the continuous change of the load. Used to evaluate the performance of the equipment under these voltage changes.
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
42-321-109-HI
Multiplexer Module
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
Clamping Voltage Tester
MIG0603CLV2
-
The MIG0603CLV2 is a generator for clamping voltage testing of varistors. It has circuits with four different source impedances and up to 15 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 500A which is maintained over the entire load range.





























