Signal Conditioning
The processing of signals to reduce noise level, amplify, attenuate, or otherwise condition.
See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Generators, Signal Meters, Signal Conditioners
-
Product
USB to RS-422/RS-485 Converter
ND-6530
-
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
Pressure Sensors
ESCP-SAPT Transmitter
-
ESCP-SAPT pressure transmitters consist of a MEMS capacitive pressure sensor die, which is underpinned by ES’ innovative microfabrication process that has been proven suitable for the mechanical, radiation and temperature environment of space applications. The full custom, radiation-hardened signal conditioning IC was designed entirely by ES, utilizing a standard deep submicron CMOS process of a European foundry.
-
Product
16-Channel Analog Multiplexer & Signal Conditioning Card
AIM-16
-
Model AIM-16 accepts, pre-amplifies, and multiplexes analog signals for application to an analog-to-digital converter installed in a host computer. Each AIM-16 concentrates 16 differential analog input channels into one single-ended analog output channel. Up to eight AIM-16s can be cascaded providing total capacity for 128 inputs to an "8-input A/D Converter."
-
Product
PXI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Hybrid, Multifunction I/O Module
779121-01
-
16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXI‑6281 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Accelerometers
-
Analog Devices accelerometers and iSensor® MEMS accelerometer subsystems provide accurate detection while measuring acceleration, tilt, shock, and vibration in performance driven application. Our portfolio leads the industry in power, noise, bandwidth, and temperature specifications, and offers a range of MEMS sensor and signal conditioning integration on chip. Our MEMS-based Circuits from the Lab® reference designs have been built and tested by ADI experts to help you jumpstart your next system design.
-
Product
Dual-Axis Accelerometer For HS3/4/4-DIFF Handyscopes, +/- 5G
TP-ACC50-25
-
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least �+/- 5G.
-
Product
RTM Discrete Signal Conditioning Board
MS 3632I
-
CPCI Rear IO Discrete Signal Conditioning Board is a signal conditioning and interface board for CPCI based Advance Compute & IO Module (MS3639i). This board primarily focusing on signal conditioning of TTL/CMOS DIO levels to required type of discrete input and output interface. Digital IO from ACIO board to discrete IO at Rear IO interface. Board takes 144 DIO from ACIO and does Open/Ground, 28V/Open, 28V/Ground configuration. In addition it shall generate additional 32 discrete input / output signals with signal conditioning and all IO interfaces are brought to two 96 Pin Euro Connector.
-
Product
RF Signal Generators
-
RF Signal Conditioning provides signal manipulation capabilities for high-frequency or broadband signals. You can use these products to augment the capabilities of connected instruments to improve attributes like accuracy and frequency range.
-
Product
PXI Analog Input Module
-
PXI Analog Input Modules feature multiple analog-to-digital converters (ADCs) as well as built-in signal conditioning. Sample rates range from 5 kS/s/ch to 2 MS/s/ch. You can choose from modules that offer up to 28 bits of resolution and up to 32 simultaneous channels. PXI Analog Input Modules offer different types of isolation and filtering, so you can choose options that meet specific application needs. The modules promote increased accuracy, high data throughput, and are ideal for scalable measurement systems with low and high channel counts.
-
Product
Remote I/O
-
ADLINK remote IO and serial communication cards are suitable for handling multiple digital signal types for IoT and other industrial applications such as facility monitoring, environmental monitoring, and industrial process control.Remote IO - NuDAM modules provide direct communication with various sensors, including performing signal conditioning, scaling, linearization and conversion to obtain temperature, pressure, flow, voltage, and current measurements. The new ND6100 series modules use Modbus/RTU remote data transmission protocols, providing customers with a comprehensive product portfolio. ADLINK's serial communication cards provide a PCI/PCIe interface and support RS-232 and CAN communication interfaces, allowing customers to choose the most suitable communication card for various automation equipment needs.
-
Product
8-CH 14-bit 100 MS/s High-Speed PXI Express Digitizer
PXIe-9848
-
The ADLINK PXIe-9848/9848H is an 8-channel, 14-bit, 100 MS/s digitizer delivering both high-accuracy measurement results and high-dynamic performance. With a PXI Express bus interface and ample onboard acquisition memory up to 512 MB, the PXIe-9848/9848H can easily manage simultaneous 8-CH data streaming. High density and high speed digitizer features ideally position the PXIe-9848/9848H for applications such as LIDAR, radar signal acquisition, and PSU (Power Supply Unit) testing applications.The PXIe-9848 provides a flexible set of input ranges from ±0.2V to ±2V, software selectable 50Ω or 1MΩ input impedance, a wide variety of triggering options and tight synchronization capability, all maximizing convenience of use. In addition, ADLINK provides the PXIe-9848H, features a x15/x50 signal condition module providing both high input voltage range of ±100V and high dynamic performance, delivering the optimum solution to measurement range expansion in a PXI system.
-
Product
Pressure Sensors
ESCP-MIS1 Sensor
-
ES Systems has developed a series of medium isolated pressure sensors suitable for applications with harsh environmental conditions where resistance to corrosive fluids or gases is required. Each sensor integrates a MEMS capacitive pressure sensor die, and a CMOS ASIC for the signal conditioning. The MEMS pressure sensor dies are underpinned by ES’s innovative microfabrication process for silicon capacitive sensors.
-
Product
Integrated
-
Columbia Research Laboratories
Columbia's Integrated Accelerometers are completely self-contained vibration measuring systems having a built-in amplifier within the housing. Low output impedance allows operation directly into standard readout equipment without auxiliary signal conditioning. This type of accelerometer must be powered by a constant current power supply like Columbia's model 5421.
-
Product
Signal Conditioning
-
Various preamplifiers and signal converters extend the range of applications for Elsys data acquisition systems.
-
Product
USB-6255, 80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device
779959-01
-
80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6255 offers analog I/O, digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
3-Slot Data Acquisition Mainframe With GPIB And Three 20-Channel Multiplexer Modules
DAQ973MB
-
The DAQ973MB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
Product
8-Channel BNC Break-out Card
ProDAQ 5824
-
The ProDAQ 5824 Signal Conditioning Cards are designed to facilitate the interface of the ProDAQ 3424 8-Ch. 24-bit Sigma-Delta ADC Function Cards to a number of sensor types. It does this by providing 8 BNC connectors on the input and a 3424 pin-compatible 50-pin SCSI on the rear of the card.
-
Product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
-
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
High Temperature Charge Mode Accelerometers
-
Charge mode output accelerometers from PCB® use piezo-ceramic sensing elements that output an electrostatic charge signal proportional to the applied acceleration. These sensors can operate at extremely high temperatures because they do not contain the built-in signal conditioning electronics that limit the temperature range of ICP® accelerometers. Charge mode sensors are used in the testing of gas and steam turbines, jet engines, high power motors, exhaust systems and automobile engines where temperatures can range from 500° F (260° C) to 1200° F (649° C).
-
Product
Signal Conditioning Modules
-
Signal conditioning modules provide signal conditioning on a per-module basis for various types of sensor or signal.
-
Product
3-Slot Data Acquisition Mainframe With GPIB, Two 20-Channel Switch Modules, And One 20-Channel Multiplexer Module
DAQ973SB
-
The DAQ973SB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, two 20-channel DAQM903A Actuator / GP switch modules, and one 20-channel DAQM901A multiplexer module. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junction20-channel actuator / general-purpose switch with independent single-pole, double-throw (SPDT) relaysbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784396-01
-
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
Dual-Axis Accelerometer For HS3/4/4-DIFF Handyscopes, +/- 16G
TP-ACC160-25
-
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least +/- 16G.
-
Product
High Speed Data Acquisition & Control Systems
Series 6700
-
Introducing the Pacific Instruments Series 6700 High Performance Signal Conditioning and Data Acquisition System, the premier Data Acquisition solution on the market. Based on the widely adopted Pacific Instruments Series 6000 system, the Series 6700 elevates performance and accuracy to levels not previously available.
-
Product
Termination Cards
-
A signal conditioning board that provides eight independent SPDT relays, eight isolated outputs, and eight isolated inputs for applications requiring medium current capacity plus I/O isolation between an embedded computer and monitoring/control points.
-
Product
16-Channel RTD Signal Conditioning Card
ProDAQ 5821
-
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
Product
RTM Analog Signal Conditioning Board
MS 3633I
-
CPCI Rear IO Analog Signal Conditioning Board is a signal conditioning and interface board for CPCI based Advanced Compute & IO Module (MS3639i). This board primarily focusing on all type of Analog input and output interface including signal conditioning from ACIO board to Rear IO interface. Board takes 16 Analog outputs and 64 Analog inputs from ACIO and does signal conditioning. In addition it shall generate additional 40 Analog input and 32 Analog output signals with signal conditioning and all IO interfaces are brought to two 96 Pin Euro Connector.
-
Product
Pod with Four Test Access Ports for 5v or 3.3V TTL Thresholds
JT 2137
-
The JT 2137 pod remains a popular choice for DataBlaster controller installations that require a compact signal conditioning pod embedded within a test fixture. The JT 2137 features four test access ports which together may be set for 5v or 3.3V TTL thresholds, although additional plug-in adapters are available that allow alternative thresholds to be set on a TAP by TAP basis (contact your local sales office for details). The 20-way 0.1″ IDC TAP headers comply with the standard JTAG Technologies 20-way pin-out and provide the additional flash programming controls Read/Busy and AutoWrite.
-
Product
Data Acquisition and General Purpose Test Equipment
-
All Fluke data acquisition products feature unique, built-in universal signal conditioning and a plug-in Universal Input Module to enable you to measure virtually any type of signal without having to purchase extra equipment. Plus, powerful, easy-to-use Windows®-based software supports easy configuration, advanced trend analysis, professional- quality reporting, and enables you to quickly build human-machine-interfaces without any programming.
-
Product
Mass Flow Controllers for Gases
-
Sensirion''s mass flow controllers are characterized by fast and accurate control of gas flow over a wide dynamic range. Based on the innovative CMOSens Technology, the heart of these mass flow controllers is a calorimetric microsensor (MEMS), which is integrated with the complete signal conditioning electronics on one single chip. While the flow is measured using the thermal measurement principle, efficient control is provided by an analog controlling circuit. This unique integrated technological approach results in excellent performance and reliability - at a very attractive cost.





























