Signal Conditioning
The processing of signals to reduce noise level, amplify, attenuate, or otherwise condition.
See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Generators, Signal Meters, Signal Conditioners
-
Product
Bi-Axial or Axial Averaging Extensometers
Model 3560
-
Jinan Testing Equipment IE Corporation
This extensometer is ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests like determining Poisson’s ratio. The Model 3560BIA uses a design unique to Epsilon, where the knife edges remain parallel during the displacement. This approach greatly reduces crosstalk between axes and allows use on round or flat specimens with equal ease. These extensometers are very easy to mount. Integral springs hold the unit on the test sample. The parallel multiple flexure design makes these units very durable.The Model 3560AVG reads axial strain only as a single averaged output. It may also be supplied with two independent outputs, one measurement from each side of the specimen. This set-up is most commonly required when an indication of specimen bending is desired. The second version, the Model 3560BIA, includes both the averaged axial strain and the transverse strain. Again, this may also be configured as dual independent axial readings, which results in a three channel extensometer.The Model 3560 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
PCI-6280 , 16 AI (18-Bit, 625 kS/s), 24 DIO PCI Multifunction I/O Device
779108-01
-
16 AI (18-Bit, 625 kS/s), 24 DIO PCI Multifunction I/O Device - The PCI‑6280 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
sbRIO-9234 , Non-Enclosed, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
782718-01
-
Non-Enclosed, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The sbRIO‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The sbRIO‑9234 is also compatible with smart TEDS sensors. The sbRIO‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti‑aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784397-01
-
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
Large Electrical Machines Bench Testing
-
The automated system for recording parameters during testing of gas turbine generators consists of several independent but interacting measuring subsystems and a signal conditioning system. The subsystems for recording "fast" signals are implemented on the PXI platform, "slow" signals are registered by a subsystem built on the basis of the Compact FieldPoint platform.
-
Product
8 Channel Sample & Hold and Signal Conditioning Board for Group3
-
All channels provide for voltage division ahead of transient suppression before going into the S&H ICs. Channels that are sampled and held use a common sample and hold pulse that samples while high and holds while low. Jumpers on each S&H chip allow buffering of analog signals where sample and holds are not required. An advantage to the buffers is that it provides a high input impedance for high impedance voltage dividers.
-
Product
Multi-purpose Signal Conditioners
-
The 482C series comprises 4-channel benchtop signal conditioners, while the 483C series offers 8-channel rack-mounted units. Utilizing identical signal conditioning electronics across equivalent 4 and 8-channel models ensures consistent performance. Both signal conditioner series offer standalone units with essential functionalities, as well as units equipped with advanced features like a front panel keypad and display or an Ethernet port for computer control. Additional features encompass gain adjustment, filtering options, LED fault indicators, and TEDS capability.
-
Product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
-
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Rugged, Long Gauge Length Extensometers
Model 3543
-
Jinan Testing Equipment IE Corporation
With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Block Down-Converter
-
RF Lambda’s block down-converters are used to convert higher frequencies down to IF. They can include front end amplifiers for lower noise figure and signal conditioning such as image rejection as required by the system.
-
Product
Accelerometers - Special Purpose
-
Analog Devices accelerometers and iSensor® MEMS accelerometer subsystems provide accurate detection while measuring acceleration, tilt, shock, and vibration in performance driven application. Our portfolio leads the industry in power, noise, bandwidth, and temperature specifications, and offers a range of MEMS sensor and signal conditioning integration on chip. Our MEMS-based Circuits from the Lab® reference designs have been built and tested by ADI experts to help you jumpstart your next system design.
-
Product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
-
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
USB-6255, 80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device
779959-04
-
80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6255 offers analog I/O, digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
RTM Actuator Signal Conditioning Board
MS 3630I
-
CPCI Rear IO Actuator Signal Conditioning Board is a signal conditioning and interface board for CPCI based Advanced Compute & IO Module (MS3639i). This board primarily focusing on Primary and Secondary actuator interface. This card shall handle excitation signals, conditioning, feedback measurement, power measurement. Card has high resolution Digital POTS, Direct Digital Frequency synthesizers, DAC, Discrete Input and Outputs, Analog measurement circuits for handling all sensor. All interface are brought to two 96 Pin Euro Connector.
-
Product
Threshold Detectors
-
A threshold detector is a device or system that produces an output signal only when the input signal, value, or condition exceeds or drops below a predefined limit, known as the threshold
-
Product
Multi-Channel Attenuation Control Unit (4-channels), DC to 6 GHz, 0 to 121 dB, 1 dB Step
J7204A
-
The J7204A is a multi-channel (4-channels) attenuation solution for signal attenuation and conditioning of up to 4 devices under test (DUT). Operating frequency from DC to 6 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7204A reduces cost of ownership and provide the best measurement accuracy.
-
Product
Averaging Extensometers for ASTM D5656 Shear Tests
Model 4013
-
Jinan Testing Equipment IE Corporation
The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
4-20mA Input A/D Converters
-
Analog Devices range of 4-20mA Input A/D Converters deliver accuracy, robustness and flexibility for Industrial Control applications. As the world’s leading supplier of data converters, Analog Devices is constantly introducing new A/D converters (ADCs) that drive system level architectures. Our portfolio of leading industrial 4-20mA Input A/D Converters offer considerable integration including, sense resistor, signal conditioning circuitry and advanced on-chip diagnostics to maximize performance and provide an integrated system level solution, all based upon robust silicon processes.
-
Product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
-
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
PCI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device
779418-01
-
16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device - The PCI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-01
-
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
Product
PXI Analog Output/Current Loop Simulator Module - 4 Channel
41-765-004
-
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Bolt Extensometers for Proof Load Testing
Model 3565
-
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
TX / RX Module
-
RF Lambda’s TX /RX modules include both a block upconverter and downconverter. They can include front end amplifiers for lower noise figure or power amplifiers for high output power of signal conditioning and image rejection as required.
-
Product
PCI-6255, 80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO PCI Multifunction I/O Device
779546-01
-
80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO PCI Multifunction I/O Device - The PCI‑6255 offers analog I/O, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Signal Conditioning
-
Sensors that are used to collect the data from the environment often don’t produce signal of characteristics optimal for an analog to digital converter (ADC) to translate to digital data. Additionally, these signals can be subject to electromagnetic interference (EMI) that introduces noise, having a negative impact on the reliability of the data. To make this analog input readable for the processing unit and dependable enough to give the desired quality of data the signal has to undergo a process of signal conditioning.
-
Product
Single Channel USB Programmable High-Pass Filter
USBPHP-S1
-
The USBPHP-S1 stand alone USB controllable module provides a single channel of high pass filtering and high-quality instrumentation amplifier for front-end signal conditioning compatible with all popular A/D converter devices. The USBPHP-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPHP-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPHP-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.
-
Product
QuadPOD Conditioning Interface
JT 2147/VPC
-
The JT 2147/VPC is a variant of the JTAG Technologies QuadPOD signal conditioning interface specifically designed for use within Virginia Panel Corporation’s mass interconnect interface. The unit integrates both the JT 2148 transceiver circuitry, two independent, programmable TAP modules (of type JT 2149) and two TAP modules with I/O (of type JT 2149/MPV) on a single board that interfaces via the VPC QuadraPaddle connectors type G20x or G14x.
-
Product
Operational Amplifiers
Op Amps
-
Operational amplifiers, known also as op amps, play a major role in analog signal conditioning applications. Invented by Karl Dale Swartzel Jr. in 1941, these products are largely used in today’s electronic devices.
-
Product
Fracture Mechanics Clip-On Gages
Model 3541
-
Jinan Testing Equipment IE Corporation
The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.





























