Breaker Identifiers
match a circuit to a breaker.
-
Product
Color Identifier
CAPSURE
-
Stores up to 100 color capturesToggles easily across multiple PANTONE LibrariesSynchronizes with popular design applications, including Adobe Photoshop, Adobe Illustrator and QuarkXPressAutomatically updates color libraries through CAPSURE SyncCompact and lightweight weighs just six ounces (with battery)Annotates colors with a voice recording and time-and-date stampLarge 1.75 inch-color viewing screen
-
Product
Optical Fiber Identifiers
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
Joinwit Optical Fiber Identifiers
-
Product
250 A Molded Case Circuit Breaker Tester
MCCB-250
-
The Vanguard MCCB-250 is a programmable, high-current source designed specifically for testing molded-case circuit breakers, thermal magnetic and solid-state overload motor-protection relays.
-
Product
Fiber Identifier
-
Fiber identifier is an essential installation and maintenance instrument which can identify the optical fiber by detecting the optical signals transmitted through them,during this process the fiber optic identifier generate no harm or damage to the fiber cable and it do not need opening the fiber at the splice point for identification or interrupting the service.This fiber identifier detects frequency tones at 270Hz, 1KHZ, 2KHZ, when traffic is present on the fiber under test, an audible tone can be heard. In the meantime, it can identify the traffic direction that indicated by LED with illumination.
-
Product
HV High Performance Circuit Breaker Analyzer
CBV-19
-
We conceived the CBV-19 to provide the best range of testing for electrical facilities such as circuit breakers (using gaz, oil, air, vacuum…) or synchronous condensers all the way up to 800kV and more. It combines Timing, Motion, Dynamic Resistance Measurements, and Vibration, all in a single test.
-
Product
Platform for Identifying Strategic Opportunities for Reducing Whole-Life Carbon
Carbon First
-
Carbon First is an award-winning platform that helps you identify strategic opportunities for reducing whole-life carbon in the early planning and design phases of infrastructure projects or portfolios.It empowers users to act earlier on net-zero strategies by highlighting bespoke carbon reduction opportunities and helping you set accurate Key Performance Indicators. It runs and compares multiple options on a visual dashboard quickly and easily, empowering companies to act effectively on net-zero goals and regulatory requirements.This digital innovation enables front-end loading in project planning, helping projects and portfolios be more successful and efficient across entire life cycles. Carbon First harnesses the highly respected Institute of Civil Engineer’s’ (ICE) Project 13 principles in infrastructure delivery, especially within digital transformation. These principles are designed to boost delivery productivity and certainty, improve whole-life outcomes, and support a more sustainable, innovative, highly skilled industry.
-
Product
Earth Leakage Circuit Breakers
-
Mitsubishi Electric Automation, Inc
Like molded case circuit breakers, these circuit breakers are utilized to open/close low-voltage circuits and protect wiring by automatically closing circuits when they''re overloaded or if a short-circuit occurs. We offer a comprehensive range of circuit breakers that provide superior performance in electrical protection, isolation and power distribution applications. Our circuit breaker products comply with various standards such as JIS, IEC, EN, GB and UL/CSA, and with easy to install accesories, the Mitsubishi Electric circuit breakers are "user-friendly" and ensure the best solution for virtually every application.
-
Product
Cable Fault Point Identifier
OCFI
-
Shanghai Tarluz Telecom Tech Co., LTD
Optical Cable Fault Identifier (OCFI) is The latest instrument of optical cable maintenance, repair equipment developed by tarluz, it can identify the physical cable fault location easily. This is an essential tool for fiber optic cable repair!
-
Product
Optical Fiber Identifier
AFI-500
-
Shanghai Fibretool Technology Co.,Ltd.
AFI-500 Optical Fiber Identifier can quickly identify the direction of transmitted fiber and display the relative core power without any damages to the bended fiber. When the traffice is present,the intermittently audible tone is activated.
-
Product
Circuit Breaker Timer
-
* Micro - Controller based technology* Very Compact and lightweight* Very accurate measurements* Available with built - in thermal printer or RS 232 interface* Available in bench top and industrial suit case models.* Economical
-
Product
Circuit Breakers for Panelboard and Controlboard
-
Mitsubishi Electric Automation, Inc
Series of MCCB and ELCB that provide maximum protection in a small frame size. A complete product offering for equipment control cabinets and distribution panels.
-
Product
Electronic Circuit Breaker Unit
-
The CorePower® DC or AC Electronic Circuit Breaker Unit replaces conventional thermal mechanical circuit breakers and functions as both a breaker and a switch for controlling loads. By placing ECBUs closer to loads, aircraft manufacturers gain a significant reduction in wire weight, need fewer system components, and lower installation labor costs while increasing safety, efficiency, and reliability. This new smaller unit requires less space and provides more flexible mounting options.
-
Product
FiberScout | Fault Identifier & Singlemode Fibre Length Tester
TS21
-
The TS21 Fiber Scout was designed and developed by Yamasaki as a cost effective and simple solution for identifying faults and testing the length of singlemode fibers. This lightweight, rugged, dustproof and water resistant piece of test equipment can list up to 8 results at one time and has three brilliant functions.
-
Product
Circuit Breaker Test Equipment
-
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.
-
Product
Optical Fiber Identifier
AFI-400
-
Shanghai Fibretool Technology Co.,Ltd.
AFI-400 Optical Fiber Identifier is an important tool for optical maintenance, which is used for nondestructive fiber identification work, can be detect in any location of both SM and MM fiber. Meanwhile it also has Visual Fault Locator module with fault location function. It is the ideal instrument for online test.
-
Product
Digital Circuit Breaker Analyzer
CT-3500 S2
-
The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessor-controlled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (24-300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers. Each timer is individually stopped by its respective dry-contact closing or opening. The CT-3500 can fully analyze the timing of all circuit breaker operations (Open, Close, Open – Close, and Close – Open). Timing results are displayed in milli-seconds and cycles on the unit’s back-lit LCD screen and can be printed on the built-in 2.5-inch wide thermal printer.
-
Product
Miniature Circuit Breakers
-
Miniature circuit breakers are applied to protect electric applications against an over current. When an electrical circuit is not protected the application can be damaged and unsafe situations may happen like fire. Mors Smitt delivers a wide range of miniature circuit breakers specially designed and tested according to railway regulations.
-
Product
Switchgear Test Systems / Circuit Breaker Testing
-
ACTAS test systems provide precise information as to the condition of the chamber and drive unit without requiring them to be opened. The sheer number of parameters to be determined, the wide variety of different types of switchgear equipment in use and the harsh environmental conditions encountered during on-site tests place extreme demands on test equipment.
-
Product
Stud Finders & Breaker Locators
-
Ultrasonic Distance Meter Laser Pointer measures from 2 feet up to 50 feetEasy-to-read LCD displayBuilt-in calculator for measuring areas and volumesAdds linear measurements, area and volumeMemory functionChoose from meter or foot unitsStud finder detects wood up to 3/4” with audio indicator & LCD displayAuto calibration stud detection
-
Product
Cable Identifier
-
K&S Engineering and Scientific Ltd
K&S Engineering and Scientific LTD's Cable Identifier Set offers the user a compact, portable solution for cable identification. Depending on the user preference, the Cable Function Generator and Cable Identifier Unit can be jointly housed in a rugged briefcase, or alternatively, for the user requiring a more rugged unit, can be delivered as two individual units each with their own carry-case. With the Cable Identifier Set, power optimum levels are selected by means of a rotary switch and the power levels are displayed on a meter located on the Cable Function Generator. As the Cable Identifier Unit is capable of detecting magnetic fields around mains cables it has the added advantage of the user being able to use this as a stand-alone unit to detect power cable configuration.
-
Product
Circuit Breaker Test System
AutoScan
-
AutoScan Circuit Breaker Test System is used for performing routine tests on circuit breakers and various other types of switchgear. This test system is designed to test vacuum circuit breakers, high voltage circuit breakers, and extra high voltage circuit breakers as per suitable standards.
-
Product
Automatic Circuit Breaker Timer Kit With Printer
-
NMC OFFERS FULLY AUTOMATIC CIRCUIT BREAKER TIMER KIT WITH IN BUILT PRINTER AND COMPUTER INTERFACE.
-
Product
Saluki S2107 Series Optical Cable Identifier (up to 36dB)
-
S2107 Series Optical Cable Identifier is an intelligent instrument designed for the construction and maintenance of optical cable lines in optical communication system. In view of the complex wiring environment and the difficulty of locating faults during the construction and long-term use of optical cables, S2107 series can provide fast, effective and accurate fault solutions. When the target optical cable is bent or shaken, the optical cable census instrument can quickly capture the vibration signal and display it through waveform and sound, so as to locate the target optical cable quickly.
-
Product
Circuit Breaker Test System
TDR9100
-
The Doble TDR9100 Circuit Breaker Analyzer is a state-of-the-art circuit breaker test set for testing all types of circuit breakers with efficient and accurate performance measurements.
-
Product
Visible Fault Identifier
TVFI
-
The Yamasaki TVFI Visible Fault Identifier is a practical palm sized solution for finding breaks, bends and faulty connectors or splices in fiber optic cable.
-
Product
Electrical Circuit Protection - Breakers
-
Eaton’s complete line up of low and medium voltage circuit breakers and fuses are used to provide circuit protection in alternative energy, commercial, industrial, mining, and military applications, where they protect against overloads and short circuits in conductors. These circuit breakers are applied in panelboards, switchboards, motor control centers, control panels, combination starters, individual enclosures, and bus duct plug-in units.
-
Product
First Trip Testing of Circuit Breakers
-
Significance of Circuit Breaker "First Trip Time"A circuit breaker may not be called upon to operate and clear a fault for years, but when a fault occurs, it is expected to operate within it's published time-current characteristics. Unfortunately, frequently this does not happen... environmental contaminants, hardened grease, vibration and other factors can adversely affect the operating time of the circuit breaker.
-
Product
Measuring Display Unit Breakers
-
Mitsubishi Electric Automation, Inc
Measuring display units (MDU) are integrated with molded-case circuit breakers and earth leakage circuit breakers for measuring, displaying, and transmitting information on cable ways. This display unit closely monitors energy consumption by measuring current, voltage, power, electric energy, harmonic current, leakage current and power factor.
-
Product
Locomotive Circuit Breaker Analyser
CBScan Locomotive Circuit Breaker
-
CBScan Locomotive Circuit Breaker Analyser is a compact and portable analyser used for testing 25 kV medium voltage circuit breakers that are used in electric locomotives for protection from the frequently occurring short-circuits in the overhead catenary system. The analyser is ideal for railway yards for performing periodic maintenance checks.
-
Product
Circuit Breaker Analysis Systems
-
When a fault such as a short circuit or current overload is detected by a protective relay, a trip impulse is sent to the circuit breaker. The circuit breaker must function as specified and interrupt the current as soon as possible or severe damage may occur. The damage caused by a malfunctioning circuit breaker can often be catastrophic, resulting in significant damage to the electrical system.