ICP Microphones
measure acoustic frequency, time and noise levels.
-
Product
ICP Microphone System
378A14
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Digital ICP® - USB Signal Conditioner
-
The Digital ICP®-USB Signal Conditioner, Model 485B39, offers plug-and-play connectivity for your measurements. Model 485B39 from The Modal Shop, a wholly owned subsidiary of PCB Piezotronics, is a pocket-sized, dual-channel ICP to USB digital signal conditioner. The unit provides any ICP sensor – accelerometers, microphones, impact hammers, laser tachometers, and more – with a digital USB output. It is truly plug-and-play, with no drivers required. Digital ICP features two BNC inputs and a 24-bit USB digital signal output, allowing a direct connection from the sensor to any PC, tablet, or smartphone device for easy data collection, analysis, and sharing on-the-go.
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
ICP Microphone System
HT378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
PROBE MICROPHONE ICP
377B26
-
Open Circuit Sensitivity (at 250 Hz)Frequency Range (+2.2/-4.9 dB)2 to 20000 HzLower Limiting Frequency (-3 dB)Inherent Noise<45 dB(A) re 20 Pa Dynamic Range(3% Distortion Limit)EnvironmentalTemperature Range (Operating)-40 to +158 F-40 to +70 C[5]
-
Product
ICP Electret Array Microphone
130A23
-
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
Product
ICP Electret Surface Microphone
130B40
-
Low-profile surface pressure microphone and preamp, prepolarized
-
Product
Microphone Arrays
-
One of the most important parts of an Acoustic Camera is the microphone array. It determines the spatial distribution of the acoustic microphones and therefore measurement performance of the whole system. In order to achieve the maximum possible performance in any given application, we offer a wide variety of microphone arrays. No matter if the measurement is beamforming, intensity or holography ... we have the right microphone array. For special applications we can design and build custom made microphone arrays according to the requirements of the application.
-
Product
Ultraminiature Microphone
MB-2200M10
-
MB-2200M10 is an ultra compact and lightweight microphone that enables measurement in narrow spaces, where have been difficult to install, without giving influence to the sound field.Its compact and lightweight features make you possible to perform measurements in a limited space, such as multi-point measurement, and measurement near the sound source. As CCLD type, the MB-2200M10 can be connected to Ono Sokki’s FFT Analyzer or CCLD supported devices.
-
Product
Microphone Interfaces
MEMS
-
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
Product
ICP Plasma System
-
The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.
-
Product
Precision Condenser Microphone
377C41
-
1/2" condenser microphone, free-field, 200 V Polarization
-
Product
Microphone Preamplifier
426E01
-
Nominal Microphone Diameter: 1/2 Gain -0.05 dBFrequency Response (0.1 dB) (re 1 kHz)6.3 to 125000 HzFrequency Response (-3 dB) (re1 kHz) Phase Linearity (<1 )32 to 20000 Electrical Noise (A-weight)<2.8 V<2.8 V[1] Output Slew Rate 2 V/S[2]
-
Product
Electret Measurement Microphone
EMM-6
-
The EMM-6 is a precision electret condenser microphone designed for measurement and critical recording applications. The extremely flat frequency response and true omni-directional polar pattern make it perfect for use with room acoustic analyzers and audio measurement systems. The EMM-6 microphone is individually hand calibrated using a laboratory standard Brüel & Kjær microphone in conjunction with a DAAS computer measuring system. Each microphone includes stand mount, foam windscreen, transport case, and its own unique calibration response graph.
-
Product
Measurement Microphone
UMM-6 USB
-
Precision condenser microphone for critical measurement and recording applicationsConnects to your PC or Mac via USB portTrue omnidirectional pattern with calibrated flat frequency responseRugged construction with high-quality componentsCompact design; includes sturdy carrying case with foam insertCompatible with most industry-standard measurement software
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Measuring Microphone
AWA14400
-
Hangzhou Aihua Instruments Co., Ltd.
*Precision acoustic measurements*Pressure variation measurements
-
Product
ICP® Shock Accelerometers
-
Piezoelectric ICP® accelerometers afford a very high signal output (+/- 5 volts full scale) and the ease of two-wire electrical connectivity. Their inherent ruggedness enables them to be severely over ranged without damage. The addition of internal mechanical isolation minimizes the high frequency stress that would otherwise be encountered by their ceramic sensing elements. This mechanical isolation, coupled with an internal 2-pole electrical filter, built into the ICP® circuitry, tailors the overall accelerometer response to assure data quality to frequencies as high as 10 kHz. Depending on the specific model, accelerations in excess of 50 kg can be successfully measured. These modern designs, with their internal elastomeric isolation materials are verified through calibration to remain dynamically linear and are enabling piezoelectric accelerometers to operate in increasingly severe acceleration environments.
-
Product
Measurement Microphone System
MK224SYS
-
The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.
-
Product
Cryogenic ICP® Accelerometers
-
Cryogenic ICP® accelerometers are specifically designed to operate at temperatures below the typical -65 ºF (-54 ºC) temperature limit of most voltage mode sensors. The use of specialized, built-in, cryogenic circuitry and quartz shear sensing technology promote survivability in demanding environments such as liquid nitrogen. Each sensor is hermetically sealed and individually tested to determine the thermal coefficient of sensitivity at -320 ºF (-196 ºC) ensuring reliable operation and accurate measurements. These sensors have been successfully used in the presence of liquid helium during structural testing of rocket boosters.
-
Product
Precision Condenser Microphone
377B11
-
Performance:Nominal Microphone Diameter:1/2 CharacteristicPressureOpen Circuit Sensitivity: 50 mV/Pa50 mV/PaInherent Noise<15 dB(A) re 20 Pa<15 dB(A) re 20 Pa Dynamic Range (3% Distortion Limit)>143 dB re 20 Pa>143 dB re 20 Pa EnvironmentalTemperature Range (Operating)-40 to +248 F-40 to +120 C Temperature Coefficient of Sensitivity (+14 to +122F (-10 to +50C))0.005 dB/F0.009 dB/C
-
Product
Outdoor Microphones
-
Is a measurement microphone for all-weather conditions designed for use with sound level meters.
-
Product
MEMS Microphones
-
A MEMS microphone is an electro-acoustic transducer housing a sensor (MEMS) and an application-specific integrated circuit (ASIC) in a single package.
-
Product
23KHZ Measurement Microphone
M23
-
The M23 is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
ICP-MS spectrometers (ICP MASS)
-
SPECTRO Analytical Instruments GmbH
SPECTRO MS is a double-focusing sector field ICP MS (ICP mass spectrometer) based on a Mattauch-Herzog geometry with a newly developed ion optic and pioneering detector technology. It is the only ICP MS instrument available on the market today that is capable of simultaneously measuring the complete mass range used for inorganic mass spectrometry from 6Li to 238U with a permanent ion beam going to the detector.
-
Product
In-line ICP® Charge Converters
-
In-line ICP® charge converters play a vital role in converting high impedance charge mode piezoelectric sensor signals into low impedance voltage signals, facilitating input to readout, recording, and analysis instruments. Specifically engineered for compatibility with high temperature piezoelectric sensors, these units are capable of operation in environments reaching up to 500°F (260°C). The series boasts ±2.5V or ±5.0 V output, offering a range of gain options, all packaged within a compact and durable casing. As a cost-effective alternative to laboratory charge amplifiers, in-line ICP® charge converters present an appealing choice for multi-channel applications.
-
Product
Sub-Miniature ICP® Pressure Sensors
-
PCB's sub-miniature 105C dynamic pressure sensors are specifically designed to fit into tight spaces where mounting space is at a premium.
-
Product
Measurement Microphone System
7052SYS
-
The 7052SYS Type 1.5TM measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 4 Hz to >20 kHz response, 20 mV/Pa sensitivity and a "A" weighted noise floor less than 20 dBA.



























