CT
1) Current Transformer 2) Computed Tomography
-
Product
Handheld Optical Fiber Identifier
JW3306C/CT
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3306C Optical Fiber Identifier is an important tool for optical maintenance, which is used for nondestructive fiber identification work, can be detect in any location of both SM and MM fiber. Meanwhile when you combined with JW3306CT Optical Signal Generator, which can realize low-frequency signal online injection, and also realize to find a particular fiber online without modulation signal in optical fiber signal .
-
Product
Open/Short Tester for Reverse Engineering Applications
Panther 2K-CT
-
Qmax Test Technologies Pvt. Ltd.
Panther 2K-CT is a versatile open\Short tester designed especially for reverse engineering application of tracing circuits of undocumented PCBA’s.Its innovative measurement technology helps tracing PCB tracks between components in a given circuit board. It can accommodate various types of clips\grabbers and connectors to access the device pins to trace the connectivity. Its user friendly software guides the user to place and move cluster of IC clips and probes to learn the connectivity and to generate netlist.
-
Product
Handheld Signal Level Meter
CT-DLM870D
-
The CT-DLM870D is a hand held signal level meter capable of reading analog, digital QAM and digital off air signal levels as well as Carrier to Noise, Bit Error Rate (BER), Modulation Error Rate (MER) and tilt.
-
Product
Current Measurements Of PWM Or Inverter, AC/DC 10~200A, Φ24mm
CTF-200DC-U48V
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
Product
Continuous Gas Analyzer
CT5400
-
Multi-component continuous gas analyzer combines QCL and TDL technologies in a single rack mount enclosure to measure process gas and monitor emissions from sub ppm to % levels. The CT5400 is ideal for measuring NOx, SO2, CO, CO2, CH 4, NH3, O2, HCl and other combustion gases identified as pollutants, ozone depleting, or responsible for global warming.
-
Product
Cable Tester
CT100
-
The intelligent, CPU-controlled CT100 accepts virtually any connector type: XLR, mono and TRS phone ( 1 /4 ", 1 /8 ", TT), RCA and MIDI. It shows which input pin is connected to which output pin. Separate LED's indicate proper shield connection and phantom power presence. The CT100 also offers an installed cable test mode and a continuity check plus a test tone generator.
-
Product
500A AC/DC Current Sensor
CT6904
-
Hioki pull-through AC/DC current sensors are best-in-class devices for use with power analyzers,, Memory HiCorders and high performance oscilloscopes. The CT6904 is a DC to 4 MHz/500A sensor, ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Digital Circuit Breaker Analyzer
CT-7000 S3
-
The CT-7000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3’s timing window is selectable between 1 second, 10 seconds, and 20 seconds.