50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
72.5-Watt DC Power Line Conditioner w/Holdup
44KS3-02
Power Line Conditioner
NAI's 44KS3-02 is a 72.5-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides a single output at 72.5 Watts either 22.5 to 30 VDC with holdup time or +16 VDC without holdup time - to all downstream DC/DC converters.
-
Product
PXIe-4136, 200 V, 1 A System PXIe Source Measure Unit
783760-01
Source Measure Unit
±200 V, 1 A System PXI Source Measure Unit—The PXIe‑4136 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4136 features 4-quadrant operation. The PXIe‑4136 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
PXI/PXIe Source Measure Unit Family
PXS(e)840x
Source Measure Unit
The PXS840x PXI SMU family is a high-speed, 4-quadrant source measure unit. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
PXIe 5-channel Precision Source/Measure Unit, 500 kSa/s, 10 pA, 30 V, 500 mA
M9615A
Source Measure Unit
The Keysight M9615A is a PXIe five-channel precision source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 uV / 10 pA.
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
Source Measure Unit
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
Fault Insertion Unit
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
3 Function Slot MOSA Nano Data Concentrator Unit (DCU)
NIU3A-DCU-01
Data Concentrator Unit
NIU3A-RDC-01 is a Modular Open Systems Approach (MOSA) Data Concentrator with low power high performance ARM Cortex -A53 processing. 8 GB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-301
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
Source Measure Unit
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
Product
USB Modular Source Measure Unit
U2722A
Source Measure Unit
The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
42-205-008 (PXIe) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
Fault Insertion Unit
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
Source Measure Unit
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit
782856-02
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
High-Speed Precision SMU (100 FA, 60 V, 1 MSa/s)
PZ2120A
Source Measure Unit
The Keysight PZ2120A is a cost-effective, high-speed precision source / measure unit (SMU) featuring best-in-class narrow pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices and integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
Fault Insertion Unit
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXIe-4144, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit
782432-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit - The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.
-
Product
Precision Source / Measure Unit (2 Ch, 100 FA)
B2902B
Source Measure Unit
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXIe-4147, 4-Channel, ±8 V, 3 A Precision PXIe Source Measure Unit
786888-01
Source Measure Unit
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing engine, you can synchronize SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4147 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
The 42-205-008 (PXIe) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.