Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
LMS-7000CCD Spectroradiometer
LMS-7000
-
LMS-7000 CCD Spectroradiometer is applied with TOSHIBA TCD1304DG linear array CCD detector, measurement speed is very quick and cost-saving.• The following wavelength range is with 0.8nm FWHM: • Integrating time is 1ms to 60s • CCD Detector is 3648pix which size is 8μm×200mμm • SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A/D is 16bit • Communicate with PC by USB2.0. The software has a rich re-develop platform which can be run in WinXP and Win7. • Optical port is SMA905
-
Product
GNG-* “Go” and “Not go”gauge
GNG-*
-
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
Product
Automatic Safety Test System
LS9955/56
-
The LS9955/LS9956 Automatic Safety Test System is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It used for luminaries, home application and motor tools safety test in production line or Lab R&D.
-
Product
Face Masks Particulate Filtration Efficiency PFE Tester
GLE-20
-
GLE-20 is an oil-salt two-in-one Face Masks Particulate Filtration Efficiency PFE Tester. According to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1, etc. It is used to test the particulate filtering efficiency of daily protective masks and medical masks, and to determine the obstruction performance of ordinary fabrics and medical protective masks against a constant flow of airflow.
-
Product
LED Thermal and Electrical Performance Analyzer
T5
-
Thermal parameter is the key index to evaluate the performance of LED. It’s very important to measure thermal characteristics of high power LED for high reliability LED applications. It will have effect on the optical parameters, electricity parameters and lifetime of LED. Therefore, design and control of the thermal dissipation is the most important thing for the manufacturers and users.
-
Product
Lamp Start, Run-up time and Flicker Test
LSRF-2
-
The (EU) NO 1194/2012rules
. Compared with which posted by theEuropean Commission Regulation (EC) NO 244/2009 Regulations dated 18th March, 2009, the new rules have complete mandatory and eco-design requirements. Start and Run-up time as the two indicators functional requirements in the industry has been more emphasis by manufacturers. -
Product
Masks Flame Retardant Performance Tester
WKS-1208
-
WKS-1208 Masks Flame Retardant Performance Tester is used to test the burning performance of the mask after contacting the flame at a certain linear velocity. It is special test instrument for the flame retardant performance of masks.
-
Product
High Power LED Aging Tester
LS600
-
• The standard LS600 has 1 Group which has 8 channels. That means LS600 can test 8 LEDs separately at one time. (Optional: it expand to 8 Groups which can test 64 LEDs separately at one time) • Aging Functions: Constant Current, Impact Pulse, On/Off Mode • Output current: 1~1000mA (Special Order Available) • Output voltage: 5V(Special Order Available) • Output frequency: 1~3000Hz, Duty Ratio: 1%-99% • Range of on-off circle: 0~9999h/59m/59s
-
Product
Electronic Ballast Analyzer
WT3000
-
• It has 8 windows to display each parameter of input and output characteristics • Frequency response for testing input current up to 1MHz, suitable for precise testing of various kind of electronic ballast • WT3000 has expanding analysis for envelope wave. • Symmetry analysis for envelope wave’s crest factor of lamp current • Sampling at ultra-high speed, dynamic analysis single frequency curve, highest sampling frequency is up to 10MHz • Portable with built-in chip micro-processor, particular suitable for development and spot production • RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7
-
Product
Multiplex Optical Maintenance Meter
LS280
-
LS280 is used to measure optical maintenance factor for high power LEDs, LED module, LED bulb or other LED luminaries. It is the important measuring equipment for performing the reliability of illuminants. • Freely set the time interval and time extent for automatic measurement • LCD Display, connect with PC via RS232 and English version software. • The test results can export Excel or PDF format and easy to compare. It can be saved by LS280 software or by USB directly. • The engineer can do LED life analysis based on the LS280 test results. • LS280 worked with High Power LED Aging Test (LS600), Multiplex LED Temperature Test (TMP-8/TMP-16) and High and Low Temperature & Humidity Chamber (GDJS-*B), it can do Flux VS Temperature VS Time, which is a perfect instrument system to meet LM-80 request.
-
Product
Thermally Protected Ballast Heating Test Chamber
TPB-UL935
-
Working room dimension: 610×610×610mm• Temperature range: RT+10℃~+100℃• Materials of inner and outside chamber: Senior stainless steel• Insulation Material: Ultra-fine glass wool insulation material• Heater: Dedicated strip heater (heating surface area of 300 × 40 mm), each group three hundred watts, a total of four groups, with the power supply in parallel.• Special wooden test sample holder• Third gear temperature measurement points (at any time monitoring and conversion)
-
Product
Electronic Components Test
-
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, m, magnetic core loss, B-H curve, U curve and I curve Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz Accuracy: 2% With 12-bit high-speed A/D, sampling rate up to 40MHz, ensuring data precise and stable test result Supermaximal database, suitable for almost all kinds of magnetic material in market, such as: circle, E ,U , ETD-EER, JAR, RM , EP , PM , EL , ER, PQ, EFD, plane E, etc Perfect software interface enables observation of curve in detail Meet international test requirements for magnetic particle ASTM E1444, ASTM E709-08.
-
Product
Digital Oscilloscope
JC2202TA
-
The JC Series Digital Oscilloscope was designed and produced by high accuracy electronic components and modules. The test accuracy is world high class. It is used in all kinds of electronic products testing.
-
Product
High Precision Spectroradiometer Integrating Sphere System
LPCE-2(LMS-9000)
-
LPCE-2 is an Integrating Sphere Spectroradiometer LED Testing System for identifying the performance of single LEDs and LED lamps. LED’s quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE127-1997, IES LM-79-08 and IES LM-80-08, it recommends to using an array spectroradiometer with integrating sphere to test SSL products. The LPCE-2 system is applied with a CCD Spectroradiometer (LMS-9000B or LMS-9000A) and worked with A molding integrating sphere with testing holder base function which will be more circle and the test results will be more accurate than the traditional integrating sphere.
-
Product
Reflection/Transmission Test Chamber
CHTR-100
-
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.