Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
Digital Power Meter (Harmonic Analyzer Model)
LS2010
-
• Measure Vrms, lrms, W, PF, Hz; • Harmonic distortion analysis for voltage & current, display total harmonic and 0-50 times; • Component harmonic, selectable for absolutely or relatively harmonic display; • Voltage range: 10.0-600.0V, Current range: 0.010-20.00A, Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit); • Simultaneously display Vrms, lrms, W, PF value on 4 windows, suitable for production line; • Can test every kinds of curve; Print both data & curve; • Communication port for PC, run under WinXP or Win7.
-
Product
Fluorescent Lamp Asymmetric Pulse Tester
UI2002C
-
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
Product
RoHS Testing Equipment (EDXRF)
EDX-2
-
Rapid development of global economy brings serious environmental issues, which is becoming the focus of all around the world. The RoHS directive EU announced on Feb 13th of 2003 became effective on Jul 1st of 2007 for the purchase of restricting the pollution caused by the dispose of electronic and electrical products. Facing this environmental protection requirement, after years of hard work on R&D, Lisun has successfully developed EDX serious EDXRF spectrometer. EDXRF can detect and measure the hazardous substances restricted in RoHS directive quickly, precisely and nondestructively.
-
Product
Masks Flame Retardant Performance Tester
WKS-1208
-
WKS-1208 Masks Flame Retardant Performance Tester is used to test the burning performance of the mask after contacting the flame at a certain linear velocity. It is special test instrument for the flame retardant performance of masks.
-
Product
Impulse Test Generator
SUG-CCITT-A
-
Impulse Test Generator SUG-CCITT-A (1a. 10/700us, 6KV, figure is according to N.1 in IEC60950-1:2005 Annex N). N.1 ITU-T impulse test generators.
-
Product
Electronic Ballast High Frequency Parameters Tester
UI2002A
-
• Measure Vrms, Irms, W, PF/Hz • Voltage range: 10~600V, Current range: 10~2000mA, Frequency range: 20~70kHz • Accuracy: Class 2
-
Product
Magnetic Core Selector
UI9702
-
• Measure relative value of μm, Bs, Br, Hc integrated factor• No need of wiring, direct testing, being convenient• Automatic selecting, out of limit alarming, freely setting of the selecting limit• Driving current for test: 0-2A, frequency for test: 20-50kHz, both continuously adjustable, Comply with actual working situation of electronic ballast• No need of adjusting the instrument every day• Digital display, easy to read, simply and quickly to operate• Print B-H curve
-
Product
Magnetic Material Analyzer
UI9730
-
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, μm, magnetic core loss, B-H curve, U curve and I curve• Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz
-
Product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
-
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Programmable AC Power Source
LSP-500VAC
-
• Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);
-
Product
Wire Damaged Tester
WDT-1
-
This equipment is designed and manufactured according to corresponding regulation in standard IEC884-1, GB299.1-96, GB16915.1-97 and other electronic accessories relevant standard. Mainly used to test damage degree of fixed connection components lead wire of with thread clamping type and no screw terminals, so as to inspect whether it can withstand mechanical stress during normal use.Specification: • Power supply: AC220V 50Hz • Test rate: 10±2r/min (GB16915.1-97: 12 ±1r/min) • Rotating radius: 100mm • Test distance: 250~500mm adjustable • Test numbers (Number of rotating): 0~999999 any set • Mass: 0.3KG, 0.4KG, 0.7KG, 0.9KG, 1.4KG, and 2.0KG (GB16915.1-97: 30N, 40N, 50N, 60N each of 2 pcs) • Stations: 2 • Dimension: 1200×1400×400 (mm) • Remarks: The mass and rotating radius can be optional as per customer requirements.
-
Product
Standard Light Source
SLS-50W
-
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
Product
LED Thermal and Electrical Performance Analyzer
T5
-
Thermal parameter is the key index to evaluate the performance of LED. It’s very important to measure thermal characteristics of high power LED for high reliability LED applications. It will have effect on the optical parameters, electricity parameters and lifetime of LED. Therefore, design and control of the thermal dissipation is the most important thing for the manufacturers and users.
-
Product
Luminance Colorimeter
XYL-VI
-
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.
-
Product
LED Power Driver online Tester
WT2080-OK
-
WT2080-OK LED Power Driver on line Tester is according to GB/T 24825-2009 and IEC 62384: 2006. It suitable for LED Driver production line testing quick test (0.1s finish the testing). The WT2080-OK can test 1pc LED Driver at one time in the production line.