Millimeter Wave
extremely High Frequency in the range of 30 to 300 gigahertz.
See Also: Wave, Extremely High Frequency, Long-Wave IR, Lightwave, Shear Wave, Sub-mm Wave, Microwave, Wavelet, Continuous Wave, Submillimeter Wave, Sine Wave, Shock wave, mmWave, MW
-
Product
Millimeter-Wave Amplifiers
-
When your application requires operating at Ka-band and above, trust Mercury Systems’ millimeter wave amplifiers to perform. With standard designs up to 65GHz and custom products available, Mercury is ready to support your high frequency requirement.
-
Product
Millimeter Wave Zero Bias GaAs Schottky Diode
HSCH-9162
-
The HSCH-9162 is suitable for medium-low barrier, zero bias detector applications. The HSCH-9162 is functional through W-band (110 GHz) and can be mounted in microstrip, finline, and coplanar circuits.
-
Product
Millimeter Wave Converter
ZVA-Z Series
-
Millimeter-wave measurements in the V, E, W, F, D, G, J and Y band – network analysis in frequency ranges from 50 GHz to 500 GHz depending on the converter model. Featuring a wide dynamic range, the RPG converters offer high operating convenience and allow fast measurements. Two-port measurements can be performed using a four-port network analyzer and two converters; no external generator is required. When using a two-port network analyzer, an external generator is needed to supply the LO signals.
-
Product
Millimeter Wave Orthomode Transducers
-
We are developing a series of millimeter wave orthomode transducers. These orthomode transducers are fullband, compact components. They achieve astounding cross-polarization while maintaining Micro Harmonics’ impressively low insertion loss.
-
Product
Microwave/Millimeter Wave Devices
-
We at AET Associates, Inc. take pride in our engineers who have in-depth technical knowledge in the areas of microwave and millimeter wave technology. We hope that we can serve you to benefit your research and development, production, and purchase strategies.
-
Product
Millimeter Wave Frequency Counter 70-170 GHz
-
Insight Product Co. offers the electronic frequency counter for frequency measurements of millimeter wave generators of continuous or pulsed signals. The counter has an auto and waiting modes of operation and a direct 6-digits reading in frequency range (70-170) GHz without an external mixer.
-
Product
Millimeter Wave Products
-
Reliable Millimeter-Wave High-Power Products for Airborne, Maritime and Ground Mobile Deployment
-
Product
Millimeter Wave Converters
ZC-Series
-
*variable output power*wide dynamic range*wide frequency range*highly stable measurement*convenient handling
-
Product
RF Detectors for Millimeter Wave
-
RF Detectors are essential microwave/millimeter wave products for most Tx (transmit sources). Transmitter output power measurement is the main application. It is essential to know the RF output power because the output power level must not go above values set by FCC regulations.The unit of power is the watt for RF detectors. But, most commonly used in most RF and wireless systems to express power is the terms of dBm or decibels related to 1 mW:View more RF Detector
-
Product
Millimeter Wave Control Devices
-
Ducommun millimeter wave products include various control devices for system integration. The CAE, CPS, CPD and CPM series control devices are discrete or MMIC based PIN diode attenuators and switches. The CAF, CAL, CAR and CPL series control devices are waveguide based mechanical tunable attenuators and phase shifters. These devices are offered to cover the frequency range from 18 GHz to 110 GHz.
-
Product
Millimeter-wave and Microwave GaAs Mixers
-
Keysight Technologies provides MMIC mixers ideal for microwave radio, aerospace and defense, and instrumentation applications.
-
Product
Millimeter-wave and Microwave GaAs Amplifiers
Amplifier
Keysight Technologies provides a variety of MMIC amplifiers ideal for microwave radio, aerospace and defense, and instrumentation applications.
-
Product
Millimeter-wave Receiver
ZRXL-Series
-
The RPG ZRXxxxL millimeter-wave receiver are optional for the following four-port vector network analyzers: R&S®ZVA24, R&S®ZVA40, R&S®ZVA50 or R&S®ZVA67, and R&S®ZVT20 (not suitable for RPG ZRX500L) with at least four ports. The converters facilitate measurements in the millimeter-wave frequency range. The RPG ZRXxxxL millimeter-wave receiver are available for the frequency bands from 50 GHz to 75 GHz (RPG ZRX75L), from 75 GHz to 110 GHz (RPG ZRX110L), from 220 GHz to 330 GHz (RPG ZRX330L) and from 330 GHz to 500 GHz (RPG ZRX500L). Other frequency bands are covered by other models from the RPG ZRXxxx receiver or R&S®ZCxxx converter series.
-
Product
Millimeter-wave and Microwave GaAs Attenuators
Attenuator
Keysight Technologies provides MMIC attenuators ideal for microwave radio, aerospace and defense, and instrumentation applications.
-
Product
Millimeter Wave Antenna Testing
-
If you are involved in antenna or system level design using mmWave or THz frequencies, then you understand the importance of dependable testing equipment. It may be that you are designing passive phase array or that you are designing a mmWave radar sensor system, but when it comes to validation of your design, simulation can only bring you so far. Phased array antennas have to be measured over the air (OTA) to ensure the radiation pattern of your design efficiently conducts energy in the right direction which is where the MilliBox comes in.
-
Product
2-26.5 GHz Traveling Wave Amplifier
1GG7-8045
Amplifier
The 1GG7-8045 is a broadband GaAs MMIC Traveling Wave Amplifier designed for high output power and moderate gain over the full 2 to 26.5 GHz frequency range. Seven MESFET cascode stages provide a flat gain response, making the 1GG7-8045 an ideal wideband power block. Ebeam lithography is used to produce gate lengths of ~0.3 mm. The 1GG7-8045 incorporates advanced MBE technology, TiPtAu gate metallization, silicon nitride passivation, and polyimide for scratch protection.
-
Product
proctorers
-
For automatic compression of simple and modified Proctor specimens 100 and 150 mm. Stand model for installation on a stable surface with CE safety door in accordance with the EU Machinery Directive. The Proctor mold used for the respective test is placed on the rotatable base plate and the corresponding monkey hammer inserted into the lifting device. Exchangeable drive disks and cams control the drop height and the rotary feed rate after each stroke. The displacement of the impact surface sample edge / center / sample edge is done by an electric drive. The entire compaction process is microprocessor-controlled with universal software and preselectable test parameters:
-
Product
60 GHz WR-15 Waveguide Tx Module
PEM010
-
The PEM010 is a highly integrated millimeter wave transmitter that covers the 60 GHz global unlicensed spectrum allocations packaged in a standard waveguide module. Transmitter architecture is a double conversion, sliding IF with wide bandwidth capability through the up-conversion chain from baseband to carrier. The I/Q interface accepts analog baseband signals which provides for flexibility in design and applications. The baseband input optionally supports FSK/MSK modulation for non-coherent applications. The transmitter incorporates a complete waveguide interface with low-loss transition between the chip and the WR15 waveguide port. The integrated package is small and lightweight, with a simple to use multi-pin ST4 connector for power, reference clock, digital control port and baseband signals. Either of two reference clocks can be used for setting 540 MHz or 500 MHz channel spacing.
-
Product
Linear Testfixture Testfixture for Mass Interconnect Cassette Interface Cassette and VPC ITA Frame Not Included, UUT 306 x 248 mm
MG-02-01 VPC G12
-
FEATURES• Linear click system with ball bearings, using gas springs• 10 mm ESD-proof top cover with aluminium reinforcement bars• Steel base cabinet with detachable aluminium back and bottom panels• Detachable interchangeable case system with an 8 mm spring loaded probe protection cover• Base cabinet fitted with a telescopic guide rail and catchTECHNICAL SPECIFICATIONS• Max. number of probes (2000N) 1300 units• Max. PCB height: 60 mm• Linear travel: 12 mm• Max UUT: 306 x 248 mm (wxd)• Outer dimensions: 470 x 490 x 100 x 170 mm (wxdxh1xh2)• Designed for Mass interconnect changeable cassette• Up to a maximum of 8 interface blocks of 160 or 170 signals• All interface blocks can be customized
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25Z-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25L-10
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1L-6-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Cable Assy 9-Pin D-Type, M/M, 1m
40-970-009-1m-MM
Cable Assembly
A 9-Pin Cable Assembly suitable for general use and constructed from PFA insulated wire. The connector assembly can be sured to the product by screwlocks.
-
Product
Miniature Rotating Optical Choppers
350C and 350CD
-
Model 350 is a high stability variable frequency optical chopper. The basic system consists of a control unit and a chopping head. It is supplied with four chemically blacked 30 mm diameter discs. These discs are of 2, 4, 10 and 40 slots and allow operation over the frequency range 10 Hz to 10 kHz.
-
Product
P2665 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1R1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Linear Testfixture for VPC iCon i1 Mass Interconnected Cassette Interface (Cassette Not Included) 6 or 10 Positions Blocks, UUT 456 x 320 mm
MG-07-01
-
FEATURES• Linear click system with ball bearings, using gas springs• 10 mm ESD-proof top cover with aluminium reinforcement bars• Steel base cabinet with detachable aluminium back and bottom panels• Detachable interchangeable case system with an 8 mm spring loaded probe protection cover• Base cabinet fitted with a telescopic guide rail and catchTECHNICAL SPECIFICATIONS• Max. number of probes (2000N) 1300 units• Max. PCB height: 60 mm• Linear travel: 12 mm• Max UUT: 456 x 320 mm (wxd)• Outer dimensions: 620 x 589 x 100 x 184 mm (wxdxh1xh2)• Equipped with dedicated cassette• Up to a maximum of 8 interface blocks of 160 or 170 signals• All interface blocks can be customized
-
Product
X-RAY Cameras Based On CCD
XiRAY
-
*High resolution direct phosphor imaging, ideal for Micro CT*Ultra-low readout noise with CCD and especially the new sCMOS sensors*Crystal clear 14 bit/pixel images*Partial readout and binning modes for enhanced sensitivity and higher speed*Non-linearity over full dynamic range <2% (of full scale) to 95% of full scale*External triggering, LVTTL*Low power consumption 6 Watt with Cooling or 2W without*Antiblooming, Enhanced Statistical Extra-Mural Absorption*Radiation hardened, Support of Energy levels 7 to 100keV*Measures just 63 x 63 x 46 mm*Peltier TE Cooled with Heatsink and optional fan
-
Product
High 0.75 (21.00) - 8.00 (227.00) Long Travel Bead Probe
BPLT-25C-8
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Balanced Upconverters
-
Are used to create a mm-wave signal by combining a lower RF frequency with a higher mm wave frequency.