Shunts
An Instrument Shunt is a resistor connected in parallel with a measuring device to move the current range beyond a particular value for which the instrument is capable of measuring directly.
See Also: Current Shunts
-
Product
Capacitance Bridge
1621
-
The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.
-
Product
Transient Voltage Suppressors (TVS)
-
A transient voltage suppressor (TVS) is an avalanche diode specially designed to clamp overvoltages and dissipate high transient power surges. ST’s Transil™ protection devices are able to shunt a high current surge for a short duration.
-
Product
Turbine Flowmeters
-
Titan’s small turbine flowmeter range use a radial flow principle based on the Pelton wheel technique. This well proven method is the ideal way of measuring low rates of flow of low viscosity liquids. For these mini flowmeters, a jet of fluid is directed at a turbine that is mounted on robust low friction sapphire bearings. The geometry of the turbine and the fluid chamber ensures that the rotational speed of the rotor is proportional to the flow rate through the device. The use of this radial arrangement allows more energy to be imparted into the turbine, so the bearing drag is far less important. Furthermore, because more energy is available the bearings themselves can be a lot stronger so increasing the life of the flowmeter. For larger flows, some of the liquid can bypass the turbine chamber, which then behaves as a “shunt” to the metered fluid. Accuracy is still maintained and the output remains linear.
-
Product
Isolation Amplifiers
-
Isolation Amplifiers provide power supply designers with a higher performing, single chip alternative to isolation techniques based on optocouplers and shunt regulators. Analog Devices ADuM3190 and ADuM4190 isolated error amplifiers have a 400 kHz bandwidth, with 0.5% typical initial accuracy at 25°C and 1% total accuracy over the extended temperature range of –40˚C to +125˚C. This provides manufacturers of ac-to-dc and dc-to-dc power supplies with a significant upgrade in speed and operating temperature range, as well as a 5× improvement in transient response.
-
Product
Precision Current Shunt
-
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
Product
Transconductance Amplifier
1620A
-
The 1620A provides high accuracy current levels from dc to over 10 kHz for calibrating ammeters, current transformers and shunts. It also provides output current up to 100 Amperes and as such may also be used as a high accuracy power supply, and as a power source in welding and bonding applications.
-
Product
Digital Power Meter, 30A
66205
-
Chroma Systems Solutions, Inc.
Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface
-
Product
Precision Micro-Ohmmeter
4176
-
Best-selling Valhalla 4176 ohmmeter measures transformers, coils, and shunts the competition can’t. The 4176 provides ultra-stable low-resistance measurements.
-
Product
68 Pin Breakout Interface
VSI-Breakout-68
-
The VSI-Breakout-68 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
Product
PXI Based Multifunction Measurement and ICT Instrument
PXI-501
Multifunction Switch/Measure Unit
The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.
-
Product
Selectable Shunt Current Sensor ±40 V, 20 MHz
CX1104A
Power Sensor
The CX1104A selectable shunt current sensor is a dedicated accessory for the CX3300 series and enables dynamic current measurements from 1 μA to 15 A up to 20 MHz bandwidth with an available calibrated resistive sensor head attached
-
Product
50 Pin Breakout Interface
VSI-Breakout-50
-
The VSI-Breakout-50 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
Product
Reactor Loss Measurement Systems
-
Measurements International Ltd.
The AccuLoss® SR2020 System by Measurements International emerges as a premium, dependable solution tailored for measuring losses in high-voltage shunt reactors. Specifically engineered to function seamlessly at remarkably low power factors, this system excels in applications demanding extensive scalability. Notably, the AccuLoss® SR2020 System offers two key advantages: unparalleled accuracy and remarkable speed.
-
Product
Ungrouped
-
Weshine Electric Manufacturing Co., Ltd
The instrument can measure single capacitor of single phase or three-phase shunt capacitor bank without removing wires.2. The instrument has the functions of inductance, resistance and current measurement.3. The instrument has two power supply modes: External AC220 V and built-in lithium battery meet various application scenarios.
-
Product
ABex Current Sense Module for Six Channel UUT Supply Monitoring
ABex TM-406 Current Sense
-
The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.
-
Product
Midi Logger
GL240
-
Its compact size contains an isolated input system which ensures that signals are not corrupted by inputs to other channels, thus eliminating wiring concerns. The GL240s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage. power ground allowing off-ground measurements using shunts, as well as powered or grounded thermocouples.
-
Product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2
-
The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Product
4-Ch DPDT 10A-250VAC 24VDC Multiplexer
H62004900
Multiplexer Module
Up to 10A 250Vac 10mOhm Measurement Shunt Controlled via YAV90304 Form F
-
Product
Signal Conditioner
DMA2
-
Din rail mountable with user selectable outputs of +/-10V, +/-5V or 4-20 mA. 10-28VDC powered suitable for battery or automotive use. Features 1000 Hz bandwidth and push-button shunt calibration.
-
Product
Microprocessor Based Indicator
-
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
Product
ADI Test Fixture
TA-6500
-
The TA-6500 test fixture combines the features of the OEM's Instrument Servo Tester(T307962), the Pointer/Flag Test Fixture(T307951) and the AD-650/600 Test Panel(T334043) all into one panel to facilitate testing of these Attitude Director Indicator's. The panel switches and adjustment pots are labeled to match the test procedure numbers and the duplicity in marking makes it easier for the technician to understand each function. The UUT interface is through a 96 pin zero insertion force(ZIF) type connector to minimize contact wear. The expanded localizer and nav input pins J2-34/35 are exposed on the panel to facilitate the insertion of a 200 ohm shunt when required. The fixtures rear panel has connectors for the required dual API/Synchro transmitter interface while the panel switches provide the correct routing of each.
-
Product
9 Pin Breakout Interface
VSI-Breakout-9
-
The VSI-Breakout-9 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
Product
Multiphase Power Analyzer
2800 Series
-
The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions. All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging. All is built into the input sections of the power analyzer, ready for measurements. It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.
-
Product
DC Power Analyzer, Modular, 600 W, 4 Slots
N6705C
-
The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software
-
Product
Shunt Assembly
RSA-8
-
The RSA-8 Recording Shunt Assembly contains 8 individual shunts with terminal block programming for either a current channel (using the shunt) or bypassing the shunt and using a dropping resistor for conversion to a voltage channel.
-
Product
Temperature Stabilized
Multiple Current Shunt
-
*IMPROVED ACCURACY*WIDE RANGE: <1 TO 300 A*HIGH IMMUNITY FROM AMBIENT TEMPERATURE CHANGESDC OR AC USE*TRANSPORTABLE*CUSTOM VALUES AVAILABLEWith new features, Ohm-Labs' model MCS Multiple Current Shunt for the first time overcomes much of the chief problem with accurate current measurement.
-
Product
Rad-Hard Analog ICs
-
ST's wide range of rad-hard QML-V qualified analog ICs covers analog-to-digital converters (ADC) and digital-to-analog converters (DAC) for telemetry, instrumentation and imaging applications. Our portfolio also includes rad-hard op amps, high-speed differential amplifiers up to 1 GHz, shunt voltage references and comparators to ensure a complete solution for signal conditioning, referencing and data conversion.
-
Product
Series Voltage References
-
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
Product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
-
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
AC Power Sources
CSW Series
-
AMETEK Programmable Power, Inc.
The CSW Series represents a new generation of AC/DC power sources that address the increasing demands on test equipment to perform additional functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the Compact CSW Series is capable of handling complex applications that have traditionally required multiple systems. The sleek integrated approach of the CSW avoids cable clutter that is commonly found in test systems. All connections are made internally and the need for digital multimeters, power harmonics analyzers, and current shunts or clamps is eliminated.





























