Reference Standards
See Also: References, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transformers, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
Standard Emission Monitoring System
CEMS-2000
-
CEMS-2000 is a multi-gas monitoring system aimed to continuously and reliably measure emissions from various industrial combustions. The adoption of the hot-wet extractive method avoids the loss of content during sampling. The system is extendable with additional parameters upon request. All output signals proceed through the data acquisition system and then upload to the DCS or environmental authority server.
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5A
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HL-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2LB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Primary VoltageE Standard: Cryocooler (Closed- Cycle Refridgerator) System
-
The Hypres Primary Voltage Standard System with cryocooler (closed-cycle refrigerator) is a complete, computer controlled system implementing a variety of voltage calibration functions. This system configuration is a cryogen-free complete Primary Voltage Standard System with parameters that are identical to the liquid helium version.
-
Product
Reference Temperature Sensors
-
AMETEK Sensors, Test & Calibration
Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-H200-1
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1G
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Standard Products
-
DLM’s standard product range is designed by experienced in-house design engineers and manufactured at our workshop in the UK by qualified technicians.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF400
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of powerfactor in low voltage instalations
-
Product
AC Reference Generators
SR21
-
Computer Conversions Corporation
The SR Series are miniature, low cost AC reference generators designed to supply 26 or 115 volt excitation to synchros or resolvers in military and industrial control applications. They accept +/-15V DC and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6”x3.1”x1”H.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1V1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard High Speed A/D Converters
-
Analog Devices high speed A/D converters (ADCs) offer the best performance and highest sampling speed in the market. The product offerings include low IF A/D converters (20 MSPS to 125 MSPS), high IF a/d converters (125 MSPS to 1.3 GSPS), and wideband ADCs (>1 GSPS). The high speed a/d converter portfolio offers cost and performance optimized solutions for various applications such as communications infrastructure, electronic test and measurement, and aerospace and defense.
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1HF-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
10 Volt Reference
8110A
-
Measurements International Ltd.
8110A 10 volt reference, Industry Leading Stability, Built-in reversing switch for + 10 V, – 10 V, 30 Days: ± 0.25 µV/V, 90 Days: ± 0.75 µV/V, 1 Year: ± 1.5 µV/V, Built-in battery backup.
-
Product
Standard Bare Fiber Spools
-
*Custom lengths to 30km of optical fiber*Designed to fit spools in the most efficient manner*Portable for easy handling and protection*Organizes fiber while ensuring performance
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5E
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Ferroalloy Reference Materials
-
NCS Testing Technology Co., Ltd.
Ferroalloy Standards by NCS
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25F-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Cold-Atom Frequency Standard
-
Rack-mount microwave atomic clock using laser-cooled 87Rb atoms. Production unit target specifications: Allan deviation 2×10-12 @ 1 s, 2×10-14 @ 104 s; flicker floor 1×10-14; absolute accuracy < 1×10-13.
-
Product
Low Voltage EMC Standards Tester
LVTGO-VBS
-
LVTGO-VBS is a range of low voltage battery simulation units for robustness and EMC standards testing. It helps engineers to meet standards stipulated by a range of manufacturers, such as JLR, Ford, VW, BMW and Mercedes-Benz.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1V-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2LB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Non Standard Connectors
-
C.C.P. Contact Probes Co., LTD.
With over 10,000 Designs, you could customize the product to achieve your spec!
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Control and Alarm Panel
8040
-
From our range of B/W Controls products we can supply the 8040 Series control panel with control relay, wired terminal block, motor starter, or a panel for just the external connections.Included in the 8040 Series standard control and alarm panel is the B/W system wiring diagram which assures quick and easy installation and the confidence that the system will work right the first time.
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.