Light Sources
See Also: Lighting, Optical Light Sources, LED Sources, Light Choppers, Opacity, Spectroradiometers
-
Product
Laser Source
TW3108
-
Techwin(China) Industry Co., Ltd
Laser Source TW3108 is designed specially aim at users with high requirements. With featuers of durable structure, large LCD display with backlight and friendly operation interface, the TW3108 advanced stability handheld optical light source provides a lot of convenience for your field work. High stability of output power and quite stable output wavelength, it is an ideal instrument for optical network installation, trouble shooting, maintenance and other optical fiber related systems.
-
Product
Multi-Meter
TW3207
-
Techwin(China) Industry Co., Ltd
Multi-Meter TW3207 integrates the functions of an intelligent optical power meter module and of a highly stable light source module in one unit which can perform closed-loop tests by incorporating both modules. Individual regimes of operation can also be manually chosen using menu operation to switch functions. A perfect combination to make your optical fiber tests a lot more convenient.
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
Quantum Sensors
-
Apogee offers two types of quantum sensors. The Full-spectrum Quantum Sensors feature an improved detector that provides accurate measurements under all light sources, including LEDs, right out of the box. The Original Quantum Sensor is less expensive and great for measuring all light sources except certain LED colors, where post-measurement correction factors need to be applied to achieve accurate readings.
-
Product
Long Light Source
LM-A
-
The long light source is compatible with the LM-101 or the LMC-20. The light is supplied with a 50 watt tungsten halogen convection cooled light source which provides suffcient energy for use with narrow band pass filters or monochronomators in the wave length range of .35 to 2.5 microns. The light beam is chopped at 200 hz by a quiet, vibration free, synchronous motor. The housing also contains a secondary LED light source and detector for synchronization of the amplifier, plus an electro-mechanical shutter to block the light output when the instrument is zeroed. An internal collimating lens produces a narrow beam (<1") so the LM-A can be used in bell-jar and large coating systems.
-
Product
Visible Light Source/Integrating Sphere
-
The Infinity VSX Series Integrating Sphere systems are ultra uniform, highly accurate broadband light sources.
-
Product
LED Measurement – UV, VIS, NIR
-
UV, VIS, and IR LEDs are replacing traditional light sources and are enabling new applications. Ophir offers a number of choices in LED power measurement - use the LED sensor finder to find the right sensor. For cases where a complete image of the beam distribution is necessary, use a beam profiling camera.
-
Product
C+L Band Broadband Light Source
S-103
-
ASE broadband source slot module of FOTS system can offer special function that is able to change optical output spectral feature variously, which is change optical output spectral feature variously, which is followed by user’s driving embedded pump LD freely. The output power of each pump LD is controlled separately by the program that is set up by user. In the case optimum ASE source output features such as wide broadband (> 80 nm @ -10 dBm/nm) and stable output power (< 0.02 dB) is needed, it is made up so that the provided Default mode along with User mode can be chosen and set up. More stable application of ASE source is possible through the combination of monitoring of ASE output power, alarm status and pump LD status with real-time optimal feedback. The embedded FPGA processor makes high speed control possible and enables monitoring and feedback routine operated stably.
-
Product
Short Light Source
LM-AS
-
The short light source is compatible with the LM-101 or the LMC-20. The light is supplied with a 50 watt tungsten halogen convection cooled light source which provides suffcient energy for use with narrow band pass filters or monochronomators in the wave length range of .35 to 2.5 microns. The light beam is chopped at 200 hz by a quiet, vibration free, synchronous motor. The housing also contains a secondary LED light source and detector for synchronization of the amplifier, plus an electro-mechanical shutter to block the light output when the instrument is zeroed. An internal collimating lens produces a narrow beam (<1") so the LM-AS can be used in bell-jar and large coating systems.
-
Product
Duplex Double Test Insertion/Return Loss Test Station
JW8302
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW8302 Duplex double test Insertion/Return Loss Test Station is a professional equipment to test CWDM device, multi-wavelength device, PLC, fiber optical patch cord and other passive optical devices. It is a new-generation precision optical instrument of JOINWIT who combined with so many years experience in optical passive detection. It equipped with VFL or 850 light source , supporting threshold determination, automatic multi-wavelength detection, system integration, secondary development, upper computer solution, etc. Double LC interface or other different interfaces can be tested simultaneously which is convenient for testing and improves efficiency; The VFL function could automatic on and off, no need to replace the connector.
-
Product
Fiber Shaker
MPX-SR3
-
Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.
-
Product
Loaded Spectrophotometer
DSCD-900
-
DSCD-900 is a highly performance spectrophotometer with test caliber upward. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula. It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers’ measurement requirement.
-
Product
Optical Talk Set
JZ4103
-
Sichuan Jiuzhou Electronic Technology Co.,Ltd
JZ4103 is a new generation intelligent instrument ,that integrates the functions of optical phone, stabilized light source and optical power meter in one unit. It is widely used for construction ,testing maintenance and attenuation measurement of the optical fiber engineering ,it is full duplex communication and has high quality conversation .It is an excellent tool for optical network field work.
-
Product
Gas Filter Correlation Carbon Monoxide Analyzer
Model T300
-
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
White Light LED Illumination System
pE-300lite
-
CoolLED's pE-300liteis a simple white light LED illumination system that offers intense, broad-spectrum LED illumination for imaging most common fluorescent stains. The pE-300lite Light Source can be fitted directly to the microscope or specified with a liquid light guide. The system is a mercury-free alternative that is safer, more controllable, and repeatable than conventional high-pressure gas discharge illuminators. Spectral coverage is from the UV (DAPI excitation) to the Red region (Cy5 excitation). The system is perfect for hospital and regular research laboratory environments and is affordable within consumables budgets.
-
Product
Rotation Luminaire Goniophotometer
LSG-1800
-
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Light source
UVM-MP
-
Measurement of maximum of 6 points is possible. By use of thee sensor amplifier box, distance between the light receiving inlet and the controller can be extended to 10 meters. Measurement start signals can be independently output by remote control. This is useful for the light source fixtures integrating shutter mechanism.
-
Product
PXIe Precision Source/Measure Unit, 15 MSa/s, 100 FA, 60 V, 3.5 A DC/10.5 A Pulse
M9603A
-
The Keysight M9603A is a PXIe precision SMU featuring best-in-their-class narrow pulse width as narrow as 10 μs. It enables dynamic/pulsed measurements with up to 15 MSa/s for broad emerging applications such as VCSEL optical devices.
-
Product
PXIe High-Speed Source/Measure Unit, 13 V, ± 1 A or 6 V, ± 3 A, 18 W
M9111A
-
The M9111A is a 1-slot, 2-quadrant PXIe module that provides stable, glitch-free sourcing and sinking, and high accuracy measurements. It offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. With industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading, the M9111A SMU speeds test time. The high-speed M9111A can change its output voltage, stabilize that voltage, and accurately measure current from Amps down to micro-Amps all in less than 1 ms so that you can move on to the next test as quickly as possible.
-
Product
Optical Switches
-
Fast and reliable optical switches to streamline your test procedures. Can be customized with a wide range of switch configurations, fiber types and connectors.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
-
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
Millimeter-Wave Noise Source, R-band, 26.5 to 40 GHz
R347B
-
The Keysight R347B noise source covers a 26.5 to 40 GHz frequency range. This waveguide noise source allows you to make accurate and convenient noise figure measurements on millimeter-wave devices. The R347B provides highly precise broadband noise at the input of the system or component under test. The noise figure meter then processes the ON/OFF ratio of noise power present in the system IF, and provides an accurate reading of noise figure and gain. The R347B noise source has remarkable ENR stability over time, which allows longer recalibration cycles and more accurate noise figure measurements.
-
Product
Performance AC Power Source, 1750 VA, 300 V, 13 A
6813C
-
Maximize your investment with five instruments in one device Increase your productivity with extensive built-in power measurement capabilities Flexible IO: LAN/LXI Core, USB and GPIB Lower your cost of ownership with global support & the longest standard warranty in the industry
-
Product
Fixed Laser Source Module
-
Keysight offers a broad choice of fixed laser sources, which are available as single-wavelength and dual-wavelength modules as part of the Keysight Lightwave Solution Platform. The Keysight 8165xA Fabry-Perot laser sources can be used in conjunction with optical power meter modules for insertion loss, optical return loss and PDL measurement of broadband components and fiber. The Keysight 81663A Distributed Feedback Laser Sources are best suited for amplifier test and WDM system test applications. Keysight covers PON and common WDM wavelengths with its 81663A Distributed Feedback (DFB) laser source modules. The precise tunability around ITU-grid center wavelength gives you the flexibility to match test setups to the latest requirements of the DWDM-system. The fine-tuning allows to shift the center wavelength from one DWDM transmission channel to the adjacent channel in dense WDM systems. The built-in isolator ensures highest laser stability, even when reflections are present in the optical path.
-
Product
Noise Source, 10 MHz to 18 GHz, nominal ENR 15 dB
346B
-
The Keysight 346B noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. The 346B's high ENR, low SWR, and variety of connectors make it a general-purpose noise source. Add special option H01 for high ENR (21 dB typical) to measure high noise figure devices, or option H42 for measuring Direct Broadcast Satellite (DBS) low noise block converters.
-
Product
SNS Series Noise Source 10 MHz to 26.5 GHz (ENR 15 dB)
N4002A
-
The SNS series N4002A noise source was designed to measure DUT noise figures reliably and accurately up to 30 dB from 10 MHz to 26.5 GHz.
-
Product
High-Speed Precision SMU (100 FA, 60 V, 15 MSa/s)
PZ2121A
-
The Keysight PZ2121A is a high-speed precision source / measure unit (SMU) featuring best-in-industry narrow-pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices, integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.
-
Product
Source/Measure Unit for Functional Test, Multiple Ranges, 80 W, Double-wide
N6786A
-
Only Keysight`s N6780 Series SMUs let you visualize current drain from nA to A in one pass and one picture unlocking insights to deliver exceptional battery life.
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
-
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
Step-Tunable Laser Source, High Power and Low SSE, Basic Line
N7779C
-
The new N7779C basic line step-tunable laser source is ideal for cost-effective testing of broadband optical devices. It can also serve as a highly stable, tunable local oscillator for receiver testing or transmission experiments.