Luminous Flux
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Absolute Luminous Flux Integrators
-
Photometric Solutions International Pty Ltd
The Absolute Luminous Flux Integrator (ALFI) is a special device for absolute measurement of the luminous flux output of lamps. It can also to measure the luminous intensity distribution of small lamps and luminaires.
-
Product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
Product
Total Luminous Flux Measurement System
-
This system enables the total luminous flux measurement of luminous intensity distribution 2 and 4 light sources based on the measurement standards of LED lightings LM-78 and LM-79 approved by IESNA (Illuminating Engineering society of North America) .
-
Product
Integrating Spheres - Luminous Flux Measurement For LEDs And Lamps
-
Konica Minolta Sensing Americas, Inc
One of the most important tests in light measurement is the assessment of the total radiant power or luminous flux of light sources using integrating spheres. An integrating sphere’s inside surface is coated with a diffusely reflecting material which guarantees complete integration and homogenization of the emitted radiation. The integrated light is then measured at the detector port.
-
Product
Optical Meters
-
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
Product
Integrating Spheres
IP-Series
-
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
Product
High Power LED Photo-color-semi Automatic Selector
-
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
Product
Spectral Light Meters For Photometric And Colorimetric Measurements
-
Comprehensive range of spectroradiometers for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens), luminous intensity (cd) as well as the colorimetric characteristic values such as chromaticity coordinates (x,y,u',v') or color rendering index (CRI), etc.
-
Product
Spectroradiometer
-
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
Product
GO-SPEX100 Goniospectroradiometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-SPEX100 delivers photmetric, colorimetric, electrical comprehensive test function for LEDs, and built-in precision temperature control platform,not only for measuring the specific temperature of the photometric and colorimetric parameters of LED, but also to measure the characteristics curve of its photometric and colorimetric performance with temperature.The test parameters include: spatial luminous intensity distribution curve, luminous flux, spatial spectral distribution, relative spectrum, absolute spectrum, color parameter, forward current and forward voltage, etc.
-
Product
GO-2000 Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-2000 is a highly automated luminaire light distribution performance test system, mainly used for all kinds of indoor lamps, road lamps and floodlights ( add B-β test accessories) light distribution performance test, total luminous flux test and electrical parameters (voltage, current, power, power factor) measurement.
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
Integrating Spheres
-
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
Product
RGB Laser Illuminance, Luminance & Optical Power Meters
TM6102/TM6103/TM6104
-
Accurately evaluate the white balance of displays that use lasers by measuring centroid wavelength and optical power, which are key characteristics in the evaluation of laser light sources. Designed to adjust and inspect RGB lasers. Meters measure radiant illumination, centroid wavelength, illuminance, luminance, chromaticity, Radiant flux (optical power) and luminous flux.
-
Product
Spectrometer & Colorimeter
-
Spectroradiometer is widely used to measure the spectral, photometric and colorimetric parameters of all kinds of lighting sources which usually include relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature(CCT), color rendering index(CRI), dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, luminous flux, Illuminance, luminance, spectral transmittance and reflectance, etc. PIMACS provides different types of spectroradiometers and colorimeter to meet the requirements in laboratories or on production lines. They are applied in the measurement for general light sources, LED & OLED products, displays, etc.
-
Product
LED Goniophotometer for Lamps
880
-
Shenzhen Chuangxin Instruments Co., Ltd.
Be used to measure the luminous intensity distribution curve intensity data spread angle and equivalent luminous flux of luminaries. Computer controls the whole test process automatically with low cost and simple operations.
-
Product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Aging and Optical Attenuation Tester
LS822
-
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
Product
Light Meters For Photometry
-
Comprehensive range of solutions for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens) and luminous intensity (cd).
-
Product
Luxmeter
Digilux 9500
-
Instrument Systems Optische Messtechnik GmbH
The Digilux 9500 of the Optronik line is a high caliber luxmeter for the precise measurement of illuminance, luminousintensity in the lab, or determination of luminous flux with an integrating sphere. It is equipped with a state-of-the-art photocurrent amplifier and microprocessor technology, and offers multiple operating and display functions with an excellent price-performance ratio.
-
Product
PCE Series Opto-Electric Measurement System
-
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
Product
LED626/620 Goniophotometer For LEDs
-
Hangzhou Everfine Photo-E-Info Co., LTD
It can measure the luminous intensity data and automatically plot the luminous intensity distribution curve and luminous flux, and the test conditions meet the CIE condition A (far field) or condition B (near field).In addition, the software can provide customers with 3D luminous intensity distribution graphic.
-
Product
LIMES 2000
-
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments
-
Product
Lux Meters
-
Shenzhen Everbest Machinery Industry Co.,Ltd.
Unit of illuminance and luminous emittance, measuring luminous flux per unit area. It is equal to one lumen per square metre. In photometry, this is used as a measure of the intensity, as perceived by the human eye, of light that hits or passes through a surface.
-
Product
Photometer
PH2000
-
The digital photometer is used with an photo detector and an integrating sphere for luminous flux lumen measurement.
-
Product
Broadband Light Meters With Integrating Sphere
-
Broadband light meters with integrating sphere for measuring laser power (W) and luminous flux (lm).
-
Product
LED Tester0.3m-2m Integrating Sphere
CX-8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Light-resistant Integrating Sphere
-
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
Product
Photometers & Colorimeters
-
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.