Electrodes
-
Product
Conductivity Switches
-
B/W Controls offers a simple conductivity holder and electrode that can be configured for multiple measurement points.
-
Product
Calibration Solutions
-
Calibration buffer solutions and deionized water are pre-mixed and color-coded to prevent errors. Ideal for calibrating electrodes and pH meters and are accurate to within ±0.01 pH at 25°C (77°F).
-
Product
TTC-1 Tracking Test Chamber
TTC-1
-
It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.
-
Product
Parallel Electrode SMD Test Fixture, DC To 3 GHz
16196B
Test Fixture
The 16196B surface mount devices (SMD) test fixture offers excellent repeatability and usability, with accurate correlation up to 3 GHz. 16196 series fixtures are custom designed to fit specific SMD sizes (see table below), and provide repeatable DUT positioning with reliable contacts to enable stable measurement results, reducing the possibility of operator-induced error. Traditionally, SMD inductor evaluation up to 3 GHz has been difficult to implement. Now with the 16196 series, it’s easy to perform accurate and repeatable measurements.
-
Product
BOMBARDING A.C. MILLIAMPERES METER
-
A Bombarding A.C. Milliamperes Meter is one of the four instruments essential for proper luminous tube processing. This instrument monitors the level of bombarder current in milliamperes that is generated by the bombarder, through the tube being processed. It is necessary to accurately monitor the current for the tubing and electrode sizes used to ensure that the right amount is applied at the appropriate time. To do otherwise may cause damage to the electrodes, fluorescent coating inside the tube and adversely affect the glass structure.
-
Product
Sensor Products: Weld Force Gage
90061
-
Model 90061 is a self-contained, portable measurement system which allows auditing of the pinch force generated between the electrodes of resistance spot welders. Resistance welding uses a pair of electrodes to clamp two base metals firmly together prior to and during application of electrical current. Poorly clamped parts result in a defective joint. A correctly clamped assembly aids in reducing the resistance in the joint and allows the current flow to properly heat the base metals to weld the part.
-
Product
Ocean and River Instruments
RINKO W
-
Rinko W is an autonomously deployable data logger for long-term DO measurements. In order to protect the sensing foil against accumulating bio-fouling, the instrument has a mechanical wiper to sweep the optical window. The optical sensor does not have a membrane neither electrolytes, thus, it need less maintenance than electrode or galvanic sensors.
-
Product
New Resistivity Inversion Software
EarthImager 3D
-
AGI is proud to introduce the new EarthImager 3D resistivity and IP inversion software. This software inverts resistivity and IP data acquired with electrodes arranged in boreholes and/or on the surface and presents a 3D volume of inverted resistivity data with advanced volume rendering technique. The final resistivity or IP image-volume can be rotated in any orientation, zoomed in and out, and translated to anywhere inside the image window in order to see the volume of interest in detail. Colors representing areas of less interest can be made transparent so that the shape of a pollution plume, for example, can be visible. With EarthImager, 3D resistivity inversion can be as easy as two steps: Read Data and Start Inversion with only a few mouse clicks.
-
Product
Handheld Water Quality Meters
LAQUA PC220
-
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
Product
Microscopic Four-Point Probes
M4PP
-
CAPRES M4PP Microscopic Four-Point Probes have an electrode pitch three orders of magnitude smaller than conventional four-point probes, and are fabricated using silicon micro-fabrication technology.
-
Product
Multi-probe for Ammonium and/or Nitrate
S470
-
S470 is a complete family of Ion selective electrodes (ISE) probes suitable for monitoring the performance of the ammonium ion (as NH4+ or NH4–N) and nitrate ion (as NO3– or NO3–N) in a liquid matrix.
-
Product
pH and Temperature Data Logger
pHTemp2000
-
The pHTemp2000 is a battery powered, stand alone pH and temperature data logger with an LCD. This all-in-one compact, portable, easy to use device will measure and record data up to 131,071 readings per channel. The pHTemp2000 will directly connect to many commonly used pH and ORP electrodes through a female BNC connector mounted on its side.
-
Product
Ion/pH/mV Meter with Single Junction pH Electrode
Ion 6+
-
Direct Ion Concentration for use with most mono- or di-valent Ion Selective Electrodes (ISE) :: mV measurement mode allows you to check performance and calibration of your ISE
-
Product
Model N8: Narrow Materials Moisture Meter
MRC001948
-
Designed for flat, curved, smooth, or rough surfaces such as cones or beams of yarn, rolls or stacks of cloth, and more. Electrode covers an area of 1 - 1/4 x 3 inches and penetrates 1/2 inch into the product.
-
Product
Dielectric Test Fixture
16451B
Test Fixture
The 16451B is used to evaluate the dielectric constant of solid dielectric materials accurately, and complies with ASTM D150. The 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture.
-
Product
Coupled Multielectrode Array Sensor (CMAS) Probes
-
CMAS probes are made from user-specified sensing materials, including carbon steels, stainless steels, and nickel-, aluminum-, and copper-based alloys. They can also be made from customer supplied materials that have the same microstructure/heat treatment as the system component materials to be monitored. The size of the sensing electrode varies from 0.1 to 3 mm (0.004" to 0.12") in diameter, depending on the application. Typical numbers of electrodes in a CMAS probe are 9, 16 or 25 for online corrosion monitoring and vary from 8 to 100 for laboratory corrosion and electrochemical studies.
-
Product
Micro Volume pH Monitor
UP-100
-
Redevelops HORIBA's founding pH measurement technology using new ultra-small capillary electrode. HORIBA's UP-100 affords ultra-low sample consumption of just 500 uL/measurement, enabling continuous pH monitoring for a variety of critical manufacturing processes that include Semiconductor (Cleaning, Etching and Plating); Chemical Manufacturing, Bio, Pharm, Food Processing, etc.Designed for 6 month continuous operation without operator intervention for minimizing downtime.
-
Product
Localized Electrochemical Impedance Spectroscopy
VS-LEIS
-
The VersaSTAT 3F applies an AC voltage to the sample emerged in electrolyte. This "global" voltage generates AC current to flow at the electrode / electrolyte interface. A dual-element probe is positioned in solution close to the surface of the sample. The electrometer measures a differential voltage measure between the two measurement elements as a measure of local voltage-drop in solution. This voltage-drop exists in solution because of current flow from local reactions at the sample, the resistance of the electrolyte and the spatial separation of the dual measurement elements.
-
Product
Miniature Two-Point Probe Set
PRF-922B
-
The PRF-922B Miniature Two Point probe accurately measures point-to-point resistance of small areas. Like Prostat's PRF-912B Miniature Concentric Ring, the PRF-922B is capable of measurements up to 1.0x1012 ohms. Built-in distance stops provide consistent electrode to sample pressure for developing repeatable measurements. Use the PRF-922B to measure small material samples, hard to assess molded areas, edges of parts, tray or tape cells and other very small objects and surfaces. The assembly is supplied with replaceable conductive electrode covers to enhance contact resistance on irregular surfaces and composition materials. Thus, measurements may be made with either the gold plated electrode contacts, or via conductive rubber covers.
-
Product
Bridge Decking Testing Equipment
-
The testing process can detect blow holes, inclusions or thin areas in 'sprayed-type' membranes. Because the concrete contains a small amount of water, it is electrically conductive and a DC Pinhole Detector can be used to create a high voltage which is passed over the surface by the use of a brush electrode. An alarm will sound to identify any small defects which can be rectified so that the integrity of the coating can be verified.
-
Product
Room Temperature Sample Holders
12962A
-
The 12962A sample holder is designed to allow accurate impedance tests of solid materials to be performed at room temperature. The sample holder consists of two parallel electrodes, one of which is fixed in position and the other which can be moved into contact with the sample by adjustment of a micrometer. The sample holder makes use of guard ring and reference techniques in order to improve accuracy by reducing “fringing” effects at the edge of the sample. The standard electrode provided is 20mm diameter.
-
Product
Earth Tester
TAURUS PRECIOHM ET
-
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
Product
Miniature Concentric Ring Set
PRF-912B
-
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
Product
Electrochemical Analyzer
EC Epsilon EClipse
-
The Epsilon EClipse™ is the latest electrochemical analyzer manufactured by BASi. It is a potentiostat/galvanostat with a second working electrode for bipotentiostat measurements. It comes with software that enables the most popular electrochemical techniques such as cyclic voltammetry, chronoamperometry, and chronopotentiometry (select Techniques below for a more complete list). The Basic Plus software can be purchased to enable pulsed voltammetry and stripping voltammetry techniques.
-
Product
pH & ORP Sensors
-
The Barben Analytical Performance Series products are 3rd generation combination pH/ORP electrodes targeted at harsh, industrial measurement applications. High pressures, strong chemicals, and elevated temperatures typically shorten the lifespan of conventional double-junction pH probes. In these applications the Performance Series sensor offers extended sensor lifespan, as well as decreased drift, and longer calibration intervals. Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High-Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations. A wide selection of sensor body styles and process fittings in a variety of corrosion resistant materials allow direct replacement of short-lived OEM pH/ORP sensors. Barben Performance Series sensors are compatible with all major manufacturers of pH analyzers and transmitters. Upgrade your analytical measurement without the hassle and expense of replacing costly field instruments.
-
Product
Rectal Probe For Mice (Isolated)
RET-3 ISO
-
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - 3/4'' long, .028'' diameter. Tip diameter .065'', 5 foot lead length. Time constant 0.5 seconds.
-
Product
Battery Boxes Testing Equipment
-
Battery boxes can be tested for faults by placing the box on a metal plate. By applying a test voltage to an electrode inside the box, the moulding can be checked thoroughly - particularly at the injection points - and any faults found. Defects will be identified by a spark passing from the electrode, through the defect itself, to earth (the conductive material placed outside the battery box.
-
Product
Resistivity Meter with Multi Electrode
POLARES
-
Till this moment the use of Electrical Resistivity Tomography (ERT) for geology has always been basically the same since its debut, based on the original vertical Electrical Soundings (VES) principles: applying a continuous current to two stakes inserted into the ground and measuring the corresponding voltage between other two. The applied current and thus the relative tension have always been continuous, with an inversion in polarity for each measure. The new tool POLARES uses an alternate current, instead, sinusoidal type, with an adjustable frequency.
-
Product
Electrosurgery Analyzers
-
Electrosurgery Analyzer is the ESU tester you can depend on for complete preventive maintenance and electrosurgical device safety to completely test these critical functions:* Measures current, voltage and power output.* Tests RF leakage from output to ensure no hazardous currents are present.* Performs Return Electrode Monitoring (REM) tests.* Measures crest factor.* Performs automatic power distribution curve at a wide range of test loads.
-
Product
Potentiostats and Galvanostats
-
Potentiostats are feedback amplifiers which control an electrode to a certain potential with respect to a reference electrode. They may control microelectrodes in animal or herbal cells, and the current is measured in picoamperes, or large-area electrodes in batteries or production cells.





























