Correlators
-
Product
ARINC 429 Test And Simulation PCI Module
PCI-C429
-
*4, 8, 16 or 32 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*Sorting according to SDI field*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
Product
SPSR-2030 (200-3000nm) Super Pure Spectral Radiation Scanning Analyzer
SPSR-2030
-
Hangzhou Everfine Photo-E-Info Co., LTD
SPSR-2030 adopts double-monochromator design, which can realize super-pure&fine full-spectrum scanning ( 200-3000nm), the test parameters including but not limited to spectral power distribution, peak wavelength, dominant wavelength, CCT (correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, and etc.
-
Product
Modulation Distortion Up To 26.5 GHz
S930702B
-
S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer
Model T360M
-
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Motadata ServiceOps
Problem Management
-
Motadata ServiceOps ITSM platform’s Problem Management solution manages the complete lifecycle of problems faced by different organizations and helps to diagnose and identify the root cause of incidents. The problem management system prevents problems and resulting incidents from happening, eliminates recurring incidents and minimizes the impact of incidents that cannot be prevented with incident management. With Motadata problem management tool, you can easily correlate incident tickets with a problem. The correlated incidents have a distinctive tag to highlight the relationship.
-
Product
Modulation Distortion Up To 53 GHz
S95070B
-
S95070B software enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 53 GHz. The wide dynamic range and vector error correction of the PXI VNA results in an extremely low residual EVM from the test setup, giving you a complete picture of your device’s performance without test system interference. S95070B software measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals through spectral correlation between the input and output spectrum, without doing demodulation. Integration with the PXI VNA’s measurement flexibility enables you to do quick modulation distortion measurements along with traditional VNA tests.
-
Product
PCIe Gen3 4K Compact, High Speed Camera for Testing
CB120MG-CM-X8G3
-
4K, compact, high speed camera for: Vehicle Impact, Airbag Deployment and Safety Restraints Testing, Digital Image Correlation (DIC), Projectile, Explosives, Ballistics, Combustion and Missile Launch Tracking, Fluid and Flow Visualization, Sports Broadcasting, Commercial Film, Television and Studio Production, Fluidics and Particle Image Velocimetry (PIV), Flat panel inspection (FPD), printed circuit board (PCB) examination and more.
-
Product
Photometric Converter
C4000
-
The C4000 converter is a multi channel controller capable of operating all optek photometric sensors. The C4000 converter allows for easy programming and operation, and can supply up to four real time configurable 4-20 mA output values correlated to any units of measure. The C4000 offers configurable relay alarms, can record and download process data, and can operate up to four sensors simultaneously.
-
Product
Partial Discharge Testing Of Transformer & Localization System
AE-150™
-
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Product
ARINC 429 Test And Simulation PMC Module
PMC-429
-
*4, 8, 16 or 32 software programmable TX / RX channels*Programmable high / low speed operation*Simultaneous operation of all TX / RX channels*PXI interrupts, star trigger, and PXI clock*Error entry and detection*128 MB RAM*Label selective triggering for recording / filtering*IRIG-B timecode encoder / decoder for data correlation*Real-time recording and later analysis of multiple channels*Sorting according to SDI field*VXI Plug & Play driver including soft front panel*Supports: C, C ++, C # and .net*Driver support: Windows, Linux, VxWorks and other systems
-
Product
Corrosion Analysis
Resipod
-
Resipod is a fully integrated 4-point Wenner probe, designed to measure the electrical resistivity of concrete in a completely non-destructive test. It is the most accurate instrument available, extremely fast and stable and packaged in a robust, waterproof housing designed to operate in a demanding site environment. The Resipod is the successor of the classic CNS Farnell Resistivity Meter.Surface resistivity measurement provides extremely useful information about the state of a concrete structure. Not only has it been proven to be directly linked to the likelihood of corrosion and the corrosion rate, recent studies have shown that there is a direct correlation between resistivity and chloride diffusion rate and even to determination of early compressive strength. This makes it one of the most versatile NDT methods for concrete.
-
Product
PXI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779115-01
-
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6229 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Modulation Distortion Up To 13.5 GHz
S930701B
-
S930701B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 13.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930701B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
ARINC 429 Test & Simulation Interface for VME
VME-429
-
Avionics Interface Technologies
4, 8, 16, 32, or 64 Software Programmable Tx/Rx Channels - Programmable High/Low Speed Operation - Concurrent operation of all Tx/Rx Channels at high data rates - Full Error Injection & Detection - Rate-oriented Label Transmission - Label Selective Trigger for Capture/Filtering - IRIG-B Time Code Encoder/Decoder for Data Correlation - ANSI Application interface supporting C, C++, C#, and .net development - Device driver support: Windows, Linux, & VxWorks (others on request) - Designed for extended temperature operations - 64-bit VME - Interface (VME master & slave capability) - Front Panel and Rear I/O (P2) Available
-
Product
Motor Test for Stepping Motors
-
*Stable measurement: Since it uses Prony braking, this model provides stable measurement unaffected by moments of inertia and no coupling loss. In addition, the resulting measurements allow data correlation via the traditional double-balance method.*Precision measurement method: This model’s judgment of synchronization loss achieves high stability using algorithms developed by Sugawara Laboratories. Measurement mode can be chosen based on step angle. For pull-in torque, startup can be measured consistently from the holding state. Allows measurement at 1-Hz resolution.*Broad measurement range: This model offers a range of seven available measurement heads, from 0.5 N to 50 N, allowing use for high-precision measurements. Through selection and use of pulleys, this model can also be used to measure small motors of 0.5 mN·m or less or 500 mN·m motors. Pulley diameters and other settings are easily configured using a personal computer running Windows®. Note: Any of the seven available heads may be attached to a single measurement component.*High-visibility measurement data: Motor characteristics are easily ascertained on automatically plotted performance graphs. Measurement data can be overlaid up to four times. In addition, the cursor can be used to read accurate values from measurement points. Hard copies of data displayed on-screen can be printed from a personal computer.*Can be controlled using standard personal computers: Allows control of measurement operations and display and storage of data from a standard personal computer running Windows®. Data is stored in CSV-format files for compatibility with other software applications.
-
Product
Real-time and Direct Correlative Nanoscopy
LabRAM Soleil Nano
-
Fully integrated system based on our OmegaScope scanning probe microscope and LabRAM Soleil Raman microscope. LabRAM Soleil Nano offers unprecedented capabilities for direct co-localized AFM-Raman and photoluminescence measurements. AFM imaging modes (topographic, electrical, mechanical, etc.) and Raman acquisition can be performed either sequentially or simultaneously at the same location of the sample surface. Optical nano-resolution is also achievable with Tip-Enhanced Raman Spectroscopy and Photoluminescence (TERS/ TEPL). LabRAM Soleil Nano is compatible with the environmental chamber for AFM and Raman measurements in controlled atmosphere and at low temperatures.
-
Product
Intel Atom® Processor-Based Embedded IoT Gateway Platform
MXE-200i Series
-
ADLINK's new Matrix MXE-200i series Embedded IoT Gateway Platform is based on the Intel Atom® SoC processor E3826 and has superior-class construction meeting a wide variety of specific industrial needs. Supporting Intel® IoT Gateway, with pre-loaded Wind RiverR IDP XT 2.0/3.1 enabling full IoT function, the MXE-200i series offers the most reliable Embedded IoT Gateway for use in harsh environments, compliant with industrial grade EMI/EMS (EN61000-6-4,61000-6-2), protecting customer assets and reducing TCO. Opposing conventional correlations between size and computing power, the MXE-200i series features large-scale performance in an ultra-compact package.
-
Product
High Power LED Photo-color-semi Automatic Selector
-
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
Product
Fibolocator
-
Fibolocator is an innovative device for measuring and characterizing breaks and other backscattering-causing faults in optical fibers. Time-resolved correlation reflectometry is the principle on which the device is based. It analyzes the backscattered light like a pulse OTDR, but unlike such OTDRs, cw laser diodes are used. The requirements for the test signal and the complexity of the system are low, which leads to very low costs for OEM subsystems.
-
Product
PXI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Hybrid, Multifunction I/O Module
779630-01
-
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6229 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
Product
Modulation Distortion For E5081A Up To 20 GHz
S960704B
-
The Keysight S960704B modulation distortion software application enables fast and accurate active device modulation distortion characterization under modulated signal conditions up to 20 GHz. The wide dynamic range and vector error correction of the ENA-X yield an extremely low residual EVM of the test setup, delivering a complete picture of your device’s signal distortion performance without test system interference. S960704B software measures EVM, NPR, ACPR, and decomposes linear and nonlinear signals by spectrally correlating input and output spectrum without needing to demodulate. Integration with the ENA-X measurement flexibility enables quick modulated signal distortion measurements along with traditional VNA tests.
-
Product
Dynamic Calibration for ROSS Streak Cameras
DynaCal
-
The DynaCal Optical Calibration Module (OCM) is designed exclusively for the Sydor ROSS Streak Camera to ensure accuracy, both over time and in situ, so you can be confident that the data from your shot is certified to be correlated to the calibration of your camera. The beauty of in situ calibration is that the cost of removing and resetting the camera is avoided—and so is the risk of the replacement of the camera and shifting or disturbing the sensitive nature of streak camera results. Only in situ calibration will reveal the real world effects of EMR, gravity, electronic noise and more when they distort your camera results.
-
Product
Modulation Distortion Up To 8.5 GHz
S930700B
-
S930700B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 8.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930700B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
Product
Test Chambers
-
The left-hand axis scales the level of the 100 measurements and the right-hand axis displays the uncertainty to a statistical confidence level of 95%; proving the repeatability is better than +/-0.25dB between the measured values. Guaranteeing repeatability, accuracy and correlation across Lab’s, across Production lines and across the World
-
Product
Carbon Monoxide Analyzer(CO)
AQMS-400
-
FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.
-
Product
Logger version chlorophyll and turbidity sensor with wiper
INFINITY-CLW ACLW2-USB
-
Infinity-CLW is an autonomously deployable data logger for long-term chlorophyll and turbidity measurements. The light sources (LEDs) of chlorophyll and turbidity sensors are highly stable, Minimizing the change over time. The instrument has a mechanical wiper that periodically sweeps to inhibit biological growth on the optical window. The turbidity sensor has a good correlation with SS (Suspended Solid) over the range. Infinity-CLW provides Highly accurate and long-term stable chlorophyll and turbidity data in oceans, rivers and freshwater.
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
-
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model T360M
-
Teledyne Advanced Pollution Instrumentation
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.
-
Product
Standard Test Systems
WaveCore™ Products
-
Textron Systems’ WaveCore family offers a variety of standard test systems with a primary application of satellite payload lab testing. Our systems can be deployed affordably for both production and engineering applications, providing industry-leading levels of data correlation with high system mean time between failures and low mean time to repair.





























