GHz Synthesizers
See Also: GHz
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
-
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 40 GHz, 50 Ω, SMA-2.9, Failsafe
42-780B-541
Relay
The 40-780B-541 (PXI) and 42-780B-541 (PXIe) are single failsafe SPDT 40 GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
Product
PXI/PXIe Microwave Relay, Dual SPDT, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-780B-572-E
Relay
The 40-780B-572-E (PXI) and 42-780B-572-E (PXIe) are dual failsafe SPDT 67 GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
Product
FieldFox C Handheld RF Analyzer, 4 GHz
N9913C
-
Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth. Measure all four S-parameters simultaneously with 115 dB dynamic range. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
Product
Infiniium V-Series Oscilloscope: 25 GHz, 4 Analog Channels
DSAV254A
Oscilloscope
25 GHz analog bandwidth (upgradable)4 analog channels Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory Get the best signal integrity with the low noise floor (1.73 mVrms at 50 mV/div) and lowest jitter measurement floor (100 fs)See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC Improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring Precision Probe)
-
Product
Differential TDR, 35 ps, 15 GHz, ESD, Sxy, OSLT 3.5MM Cal Kit, Aluminum Case, Internal Battery
T3SP15D-B-BUNDLE
-
Differential TDR,35ps Rise Time, ESD protection,2 phase matched 3.5mm cables,3.5mm Cal. Kit, Battery.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 8 GHz, 50 Ω, N-Type, Remote Mount, Failsafe
42-788-111-E
Multiplexer Module
The 40-788-111-E (PXI) and 42-788-111-E (PXIe) are single failsafe SP10T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe Microwave Relay, Triple SPDT, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-780B-573-E
Relay
The 40-780B-573-E (PXI) and 42-780B-573-E (PXIe) are triple failsafe SPDT 67 GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
Product
NI-5793, 200 MHz to 4.4 GHz RF Adapter Module For FlexRIO
782512-01
RF Adapter Module
The NI‑5793 provides continuous frequency coverage from 200 MHz to 4.4 GHz. It features a single-stage, direct conversion architecture that provides high bandwidth in the small form factor of a FlexRIO adapter module. The onboard synthesizer, which is the local oscillator (LO), sets the center frequency for acquisition and generation, and you can export it to other modules for multiple input, multiple output (MIMO) synchronization. You can also import the LO from an external connector, enabling synchronization of up to eight NI‑5793 modules.
-
Product
cRIO-9048, 1.60 GHz Quad-Core CPU, 4 GB Storage, -40 °C to 70 °C, Kintex-7 70T FPGA, 8-Slot CompactRIO Controller
785621-02
Embedded Controller
The cRIO-9047 is a rugged, high-performance, customizable embedded controller that offers Intel Atom quad-core processing, NI-DAQmx support, and an SD card slot for … data-logging, embedded monitoring, and control. It includes a Kintex-7 70T FPGA with LabVIEW FPGA Module support for advanced control and coprocessing. The controller provides precise, synchronized timing and deterministic communications using Time Sensitive Networking (TSN), which is ideal for highly distributed measurements. This controller offers several connectivity ports, including Gigabit Ethernet, USB 3.1, USB 2.0, RS232, and RS485 ports. You can use the USB 3.1 ports to add a local human machine interface and program, deploy, and debug software, which simplifies application development.
-
Product
Orotron (High-Power BWO) Based Sources 120 To 370 GHz
-
Insight Product Company offers Orotron based sources of radiation at frequencies 120 to 370 GHz. The Oroton tube is installed inside the permanent magnet and does not require any adjustment by the customer. The Orotron sources are wide-banded, small in size, very reliable, powerful, and easy to operate. We offer phase-locking as an option on our Orotron based sources to maximize the phase and frequency stability.
-
Product
Waveguide Harmonic Mixers (smart mixer), 50 to 75/80 GHz
M1970V
-
The Keysight M1970V 50 to 75/80 GHz waveguide harmonic mixer is an un-preselected mixer that will extend the operating frequency range of the N9030A PXA, N9020A MXA, and N9010A EXAsignal analyzers up to 80 GHz. Smart features are embedded to help you to greatly simplify your overall test setup and improve your DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
Product
CobaltFx 9 GHz 4' FET RF Cable Kit
-
This is a Set of 4 cables, standard length 4 ft, for one extender: ULC50SMSM.4 cable (4)
-
Product
Infiniium UXR-Series Oscilloscope: 80 GHz, 4 Channels
UXR0804A
Oscilloscope
The UXR0804A is the 80 GHz, 4 Channel, UXR-Series Real-Time Infiniium Oscilloscope.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 40 GHz, 50 Ω, SMA-2.9, Failsafe
42-784B-142
Multiplexer Module
The 40-784B-142 (PXI) and 42-784B-142 (PXIe) are dual failsafe SP4T 40 GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 50 GHz, 50 Ω, SMA-2.4, Terminated, Remote Mount, Failsafe
42-785C-552-TE
Multiplexer Module
The 40-785C-552-TE (PXI) and 42-785C-552-TE (PXIe) are dual failsafe SP6T 50 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
ATEX & CID2 Anti-Explosion Certified Robust DIN-rail Fanless Embedded System With Intel® Atom® Processor E3827 (1.75 GHz)/E3845 (1.91 GHz)
rBOX510-6COM (ATEX/C1D2)
-
The rBOX510-6COM(ATEX/C1D2) robust din-rail fanless embedded system is certified with ATEX and C1D2 for use in hazardous environments where ignitable concentrations of flammable gases, vapors or liquids might exist. The embedded system supports the dual-core Intel® Atom™ processor E3827 1.75GHz SoC with the onboard 4GB DDR3L system memory. The din-rail heavy-duty embedded PC adopts an IP30-rated aluminum and steel enclosure, and can perform in wide temperatures ranging from -40°C to +70°C. To prevent ESD and over-voltage, the compact embedded box PC is equipped with four isolated RS-232/422/485 ports, two isolated 10/100/1000Mbps Ethernet ports, and one isolated DIO (8-IN/8-OUT) port. One 2.5" SATA SSD, one mSATA and one CompactFlash™ socket are available for storage. More I/O features include one USB 3.0 port, one USB 2.0 port, two COM ports, and one VGA output. In addition, box PC comes equipped with a wide range 12 - 48VDC power input with a terminal block and has overvoltage and reverse protection. The box PC provides two watchdog timers and RTC battery function. Pre-installed with Linux, Windows® 8 Embedded and Windows® 7 Embedded, the embedded system provides programmers with a friendly environment for developing application software at a lower cost. For secure mounting, the rBOX510-6COM(ATEX/C1D2) can be easily installed on a DIN-rail mount or in an enclosure box.
-
Product
PXI/PXIe Microwave Relay, Dual SPDT, 40 GHz, 50 Ω, SMA-2.9, Internal Termination, Failsafe, Remote Mount
40-781A-422-E
Relay
The 40-781A-422-E (PXI) and 42-781A-422-E (PXIe) are dual failsafe SPDT 40 GHz microwave relay modules with internal terminations and remotely mounted relays. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
Gyro-Klystrons At 34 & 93 GHz
-
Insight Product Co. offers gyro-klystrons operating at 34 GHz and 93 GHz with output power of 250 kW and 340 kW, respectively.
-
Product
Multiport Coaxial Switch, DC To 20 GHz, SP6T
L7106B
-
Improve signal accuracy with this terminated switch that provides unmatched isolation, typically 90 dB at 12 GHz.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP8T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
40-788-022-TE
Multiplexer Module
The 40-788-022-TE (PXI) and 42-788-022-TE (PXIe) are dual failsafe SP8T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
Coaxial Transfer Switch, DC to 40 GHz
87222D
-
Flexibility is essential in signal routing applications, and the Keysight 87222D 4-port coaxial transfer switch offers just that. It p rovides exceptional repeatability, low insertion loss, and high isolation. These switches provide simplification of design in signal routing and conditioning applications. The Keysight 87222D can be used in a variety of applications such as, a drop-out switch, switching two inputs and two outputs, or signal reversal switching.
-
Product
FieldFox Handheld Microwave Signal Analyzer, 32 GHz
N9960B
Signal Analyzer
A lightweight, durable, software-enabled, microwave signal analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.
-
Product
Frequency Converter Test Solution Up To 50 GHz
N5245BP
-
The N5245BP provides the N5245B 50 GHz PNA-X network analyzer, application software and accessories for frequency converter test up to 50 GHz. This bundle product
-
Product
Coaxial Waveguide Adapter, Type-N (f), 8.2 to 12.4 GHz
X281A
-
The Keysight X281A adapter transforms waveguide transmission line into 50-ohm coaxial line. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
Product
PIN Solid State Switch, 100 MHz to 18 GHz, SP4T
P9404C
Matrix Switch Module
The Keysight P9404C PIN solid state switch maximizes your operating frequency range from 100 MHz to 18 GHz. Providing superior performance in terms of isolation, insertion loss and return loss, the P9404C is particularly suitable for high-speed RF and microwave switching applications such as switch matrixes in instrumentation, communications and radar. These switches provide ultra-fast switching speed to increase throughput in manufacturing.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 40 GHz, 50 Ω, SMA-2.9, Terminated, Remote Mount, Failsafe
42-785C-441-TE
Multiplexer Module
The 40-785C-441-TE (PXI) and 42-785C-441-TE (PXIe) are single failsafe SP4T 40 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Infiniium UXR-Series Oscilloscope: 70 GHz, 2 Channels
UXR0702A
Oscilloscope
The UXR0702A is the 70 GHz, two-channel Infiniium UXR-Series real-time oscilloscope.
-
Product
PXIe Microwave Relay, Dual SPDT, 26.5 GHz, 50 Ω, SMA, External Termination, Failsafe
42-781A-322
Microwave Relay Module
The 40-781A-322 (PXI) and 42-781A-322 (PXIe) are dual failsafe SPDT 26.5 GHz microwave relay modules with external terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
Product
2-port E-Band VNA Using Streamline 20 GHz 4-port Network Analyzer
N5253E1
Network Analyzer
Cost-effective 2-port E-band vector network analyzer (VNA) system configured with a Streamline VNA and frequency extenders.