2-wire
resistance measurement method.
-
Product
PXI Switch - 24-CH 2-Wire Multiplexer Module
PXI-7921
-
ADLINK PXI-7921 is a relay multiplexer which consists of 24 2-wire relays (DPDT, 2 Form C). As a multiplexer, the PXI-7921 provides 48x1 1-wire, 24x1 2-wire and 12x1 4-wire configurations. Users could choose one of the configurations by software. PXI-7921 typically connects one instrument, such as a DMM, a digitizer or a signal source, with many points which need measurement or excitation. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7921, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
Product
VXI 16-Channel, 2-Wire LVDT/RVDT Simulation
65DL1
-
NAI’s 65DL1 is a 16-channel, 2-wire, LVDT/RVDT Simulation Instrument on a VXI board. This single-slot, message-based board provides 16 independent, transformer-isolated, LVDT/RVDT, programmable 2-wire outputs (up to 34 V), wrap-around self-test, and an onboard programmable excitation supply.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
-
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays
M9120A
-
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
Product
PXIe-2738 , 256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module
782835-38
-
256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
PXIe-2529, 128-Crosspoint, 4x32 OR 8x16, 2-Wire PXI Matrix Switch Module
780587-29
-
128-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or an 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXIe‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix topology With Column Protection Resistors
782385-10
-
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
PXI High-Density Matrix Switch: 4x64, 2-Wire, 100Vrms/0.5A, Reed Relays
M9121A
-
The M9121A is a 4x64 full crosspoint switch matrix offering high-density, high-speed signal switching in a single PXI module. The 2-wire matrix allows multiple channels to be connected in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the high-speed, long-life reed relays to support signal switching up 100Vrms with 10W maximum power. The 4-wide bus is ideal to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
Product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix Topology Without Column Protection Resistors
782385-09
-
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Digital And Analog Call Simulation
-
GL’s T1 E1/Analog Test Suite supports analysis and emulation of legacy protocols (MFCR2, E&M, SS1/SS4, SS5, Voice Call Signaling, 2-wire Call, SF Signaling (DTMF)) applicable to Federal Aviation Administration "FAA" within their National Airspace System "NAS" Ground-to-Ground Air Traffic Control Network and Voice System (NVS) to Analog Interphone.
-
Product
Interface
RCEI-530
-
Available in a range of configurations to match your needs, the RCEI-530 provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols. The RCEI-530 supports maximum data throughput on all channels while providing onboard message scheduling, label filtering, multiple buffering options, time-tagging, error detection and avionics-level I/O discretes, with support for either 33 MHz or 66 MHz PCI interfaces.
-
Product
Earth Ground Tester
-
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
Product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
-
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
Product
Dining Isolation Amplifier
-
Knick Elektronische Messgeräte GmbH & Co. KG.
To feed and Isolation of 2-wire transmitters / sensors or SMART transmitters with HART transmission. Working voltage up to 2500 V AC / DC. Available for hazardous and non-hazardous area.
-
Product
LVDT Signal Conditioner
NTC-6000
-
Quick and easy setup with front panel push buttons and LED indicatorsSelectable excitation frequency, analog outputs and bandwidthAutomatic excitation synchronization for multiple unit systemsSelf-diagnostics for LVDT failure, disconnect, or short circuitDigital communications via RS-485 2-wire multi-drop busHot swapability — setup can be saved and reloaded via RS-485 portCybersecurity lockout and tamper detectWorks with nearly any AC LVDT, RVDT, or LVRT half bridge
-
Product
Signal Conditioners
-
Process transmitters isolate, filter amplify, and convert sensor signals to 4-20mA current or 0-10V voltage signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, 3-wire DC-powered transmitters, or 4-wire AC/DC-powered transmitters. 3-wire and 4-wire models are available as 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount version are available. Configuration is easy with Windows software, push-buttons, switches, or pots for span/zero settings depending on the series.
-
Product
Inputs Temperature Data Logger – Pt100
HD32.7
-
The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes. The probes can be Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000.
-
Product
Banana-Triax Adapter For 4‑Wire (Kelvin) Connection
N1297B
-
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
Product
Interface
RAR-PCIE
-
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.
-
Product
Temperature Sensors
TT420-LT
-
Features• 2-wire, loop-powered 4-20 mA analog output• Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner• Integral 1/2" flexible liquid-tight conduit fittings• TT420Z-LT 1/4” stainless steel probe with 1/8 NPT adapter• TT420S-LT 3/8-16 threaded stud probe • FM approved, Dust Ignition-proof• Class II and III, Div I (E, F, G); NEMA 4
-
Product
Interface Technology ProLine
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Isolation Amplifier for DC voltage and current measurement with galvanic isolation, active and passive standard signal isolation amplifier, supply isolation amplifier for supplying 2-wire sensors, transmitter for temperature and AC signals, isolating amplifiers for high voltages and shunt applications. T
-
Product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix topology With Column Protection Resistors
782385-04
-
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Digital Power Recorder
MPR-601W-01
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
Product
Keysight Dual/Quad 4x8 Reed Matrix for 34980A
34933A
-
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current
-
Product
In-Line IR Sensor
ILA
-
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Product
Keysight Dual 4x8 Armature Matrix for 34980A
34931A
-
The Keysight 34931A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 configurations 64 2-wire cross-points Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter Latching armature relays 300 V, 1 A switch; 2 A carry current
-
Product
Emergency/Panic Button
ENVIROMUX-EBS
-
Sends activation signal when button is pressed. For normally closed or normally open circuit connections. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft (305 m). Dimensions WxDxH: 1.7x2.9x4.6 in (43x74x117 mm). Regulatory approvals: RoHS.
-
Product
PXI-2529, 128-Crosspoint, 2-Wire PXI Matrix Switch Module
778739-01
-
The PXI‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXI‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
Isolated RS-485
-
Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications. The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus.