2-wire
resistance measurement method.
-
Product
PXI Switch - 4x8 2-Wire Matrix Module
PXI-7931
Matrix Switch Module
ADLINK PXI-7931 is a matrix module with 32 cross-point 2-wire relays (DPDT, 2 Form C). The default configuration of the PXI-7931 itself is a 4-group 2x4 2-wire matrix. With the termination board, TB-6231, users could flexibly choose one of the configurations: one 4x8, two 4x4, one 2x16, two 2x8 and four 2x4. Any contact of the PXI-7931 can connect to other contacts, individually or in combination. The PXI-7931 matrix module simplifies the wiring and makes it easy to change the internal connection path. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7931, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
Product
External Temperature for 3-wire PT1000 Probe
TGP-4204
-
PT1000 probes are available with this logger that will record down to -200C, making them suitable for cryogenic applications. The probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
Product
Toxic Gas Detector
SMC 4501-XX
-
The SMC 4501-XX Detector monitors toxic gases such as Hydrogen Sulfide, Carbon Monoxide, Oxygen Deficiency, Chlorine Dioxide, and others. Utilizing 2-wire loop-powered technology, the 4501-XX requires less wiring, leading to better protection from wiring errors.
-
Product
Serial Bus Buffers, Extenders, and Accelerators
-
The Analog Devices family of I2C solutions support hot swappable, 2-wire bidirectional bus buffers to allow I/O card insertion into a live backplane without corruption of the data and clock busses. Additional supported 2-wire buses include SMBus, PMBus, the ATCA intelligent platform management bus (IPMB), and the HDMI DDC bus. I2C/SMBus Accelerators improve bus transitions to allows multiple device connections or a longer, more capacitive interconnect, without compromising slew rates or bus performance. ADI's software-programmable and pin-selectable I2C multiplexers help resolve I2C address limitations, increase fan-in or fan-out, and integrate bus buffers and rise time accelerators for an all-in-one solution. Resistor configurable I2C address translators can be configured with over 100 unique slave addresses to allow multiple slave devices with the same address to coexist on the same bus.
-
Product
Banana-Triax Adapter For 2‑Wire (Non-Kelvin) Connection
N1297A
-
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
Product
External Temperature for PT100 Probe
TGP-4104
-
This data logger uses an external PT100 probe to record high temperatures. Probes are available to measure up to 300 and 600C. These are listed in the 'You will also need' section. The PT100 probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
Product
RS232 / RS485 / RS422 / Ethernet Surge Protectors
-
Our passive, rugged, industrial-grade RS232 / RS485 / RS422 / Ethernet surge protectors are designed for direct industrial DIN-rail mounting and they come with two (2) or three (3) stages of surge protection — Gas Discharge Tube (GDT), protection resistors, and Transient Voltage Suppressor (TVS) - for maximum protection. From 2-wire RS485, 4-wire RS422 / RS485, to 10 / 100 / 1000M Ethernet, CommFront's surge protectors safeguard your data lines and provide you with a peace of mind.
-
Product
Legacy Liquid Detection Rope Sensor
ENVIROMUX-LDSx-y
-
For warning of flooding. Detects liquid depth >0.1" (2.5 mm). Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid or moisture, except deionized water. RJ45 connector. Voltage Supply: 12VDC. Current Consumption: 20mA. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL). Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Powered by ENVIROMUX-SEMS-16U and SERIMUX-S-x. Regulatory approvals: CE, RoHS. Requires the ENVIROMUX-SEMS-16U and SERIMUX-S-x to operate. Use self-adhesive clips (ENVIROMUX-CLP10-LD) to prevent sensor rope cable from shifing after installation. ENVIROMUX-CLP10-LD includes 10 clips.
-
Product
Party Line Intercom Conversion
COMMS Series
-
The stand-alone COMMS 300 and the OG-COMMS openGear® units provide a means to interface between two channels of 2-wire party-line intercom audio and two channels of 4-Wire analog line-level signals. The unit is capable of performing auto nulling for each channel with the push of a button. In addition, each of the 4-Wire input and output channel levels are monitored and displayed on easy to understand front panel VU meters.
-
Product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix Topology Without Column Protection Resistors
782385-11
Terminal Block
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Speed Sensor Intrinsically Safe
ST420
-
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected • Works with Electro-Sensors magnetic pulser discs / wraps Rugged stainless steel M18x1 housing; UL listed, Intrinsically Safe (IS); Class I, Div I (C, D) Class II, Div I (E, F, G)
-
Product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
-
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
Product
Ultra High Density Matrix Switch Card
1260-45
Switch Card
The Astronics 1260-45 offers the highest-density switching matrices in a single-slot C-size VXI module, configurable as 11 different matrices from four 4x16 2-Wire to one 16x16 two-wire. Easily extend this module externally to build a larger matrix in a single VXI chassis to satisfy even the most dense applications.
-
Product
Industrial Grade PCI DIO 96 Board
MS 1817
-
*96 digital input/output lines*Support s all PPI Modes (Mode0, Mode 1 and Mode 2)*5 V TTL/CMOS*Compatible with NI DIO Card*2-wire handshaking capability*Known power-up
-
Product
Temperature Sensors
TT420-LT
-
Features • 2-wire, loop-powered 4-20 mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Integral 1/2" flexible liquid-tight conduit fittings • TT420Z-LT 1/4” stainless steel probe with 1/8 NPT adapter • TT420S-LT 3/8-16 threaded stud probe • FM approved, Dust Ignition-proof • Class II and III, Div I (E, F, G); NEMA 4
-
Product
REM-11115, 4-Channel, 2-Wire Analog Output Module for Remote I/O
784749-01
Analog Output Module
4-Channel, 2-Wire Analog Output Module for Remote I/O - The REM‑11115 is an analog output module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11115 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. You can use the REM‑11115 for voltage or current output, and it features a 2‑wire spring terminal connection method. The REM‑11115 has selectable output ranges and short-circuit-proof output channels.
-
Product
NI TB-2643B Terminal Block for NI 2532B as 1-Wire Dual 4x64 Matrix or 2-Wire 4×64 Matrix topology With Column Protection Resistors
782385-08
Terminal Block
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Inputs Temperature Data Logger – Pt100
HD32.7
-
The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes. The probes can be Pt100 with SICRAM module, direct 4-wire Pt100 or direct 2-wire Pt1000.
-
Product
Interface RS-485 and RS-422
-
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Product
RS-485 and RS-422 Transceivers
-
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Product
PXIe-2525, 64‐Channel, 2 A, Multibank, 2‐Wire PXI Multiplexer Switch Module
780587-25
Multiplexer Module
64‐Channel, 2 A, Multibank, 2‐Wire PXI Multiplexer Switch Module —The PXIe‑2525 is a high‐density PXI multiplexer switch module that is ideal for routing signals within automated test systems. It uses electromechanical relays to perform immediate switch operations in one of the following 2‑wire multiplexer configurations: 16 bank 4x1, octal 8x1, quad 16x1, dual 32x1, and 64x1. The PXIe‑2525 also features onboard relay counting for relay monitoring.
-
Product
Interface
RAR-PCIE
Interface
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.
-
Product
Analog Output Module For Remote I/O
Analog Output Module
The Analog Output Module for Remote I/O features a 2-wire spring terminal connection, selectable output ranges (0 V to 10 V, ±10 V, 0 V to 5 V, ±5 V, 0 mA to 20 mA, 4 mA to 20 mA, and ±20 mA) output ranges, and short circuit proof outputs. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the Analog Output Module for Remote I/O from a real‐time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low‐cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high‐speed or specialty measurements.
-
Product
Digital Power Recorder
MPR-601W-02
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and 3phase 3wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
Product
- RS-232 to RS-485 2 Wire with LCD Display
Model 366
-
FEATURES: DataSpy® Status Display; Implements Low Cost LAN; Supports 32 Users; Uses Single Twisted Pair; External DTE/DCE Switch; Programmable Contention; Selectable Termination. The Model 366 allows interfacing RS-232 based equipment with networks/equipment using RS-485.
-
Product
LVDT Signal Conditioner
NTC-6000
-
Quick and easy setup with front panel push buttons and LED indicatorsSelectable excitation frequency, analog outputs and bandwidthAutomatic excitation synchronization for multiple unit systemsSelf-diagnostics for LVDT failure, disconnect, or short circuitDigital communications via RS-485 2-wire multi-drop busHot swapability — setup can be saved and reloaded via RS-485 portCybersecurity lockout and tamper detectWorks with nearly any AC LVDT, RVDT, or LVRT half bridge
-
Product
Signal Conditioners
-
Process transmitters isolate, filter amplify, and convert sensor signals to 4-20mA current or 0-10V voltage signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, 3-wire DC-powered transmitters, or 4-wire AC/DC-powered transmitters. 3-wire and 4-wire models are available as 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount version are available. Configuration is easy with Windows software, push-buttons, switches, or pots for span/zero settings depending on the series.
-
Product
Emergency/Panic Button
ENVIROMUX-EBS
-
Sends activation signal when button is pressed. For normally closed or normally open circuit connections. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft (305 m). Dimensions WxDxH: 1.7x2.9x4.6 in (43x74x117 mm). Regulatory approvals: RoHS.
-
Product
Digital Power Recorder
MPR-601W-01
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
Product
4x8 2 Wire USB Modular Switch Matrix
U2751A
Switch Module
The U2751A USB Modular Switch Matrix offers a flexible connection path between the device under test and the test equipment, thus allowing different instruments to be connected to multiple points on the device under test at the same time. This instrument is able to support measurements at a high bandwidth of up to 45MHz. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity