Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
Calibration Light Sources
-
For wavelength calibration, Avantes offers a variety of sources including Argon, Mercury-Argon, Neon, Zinc, and Cadmium. All Avantes spectrometers are factory wavelength calibrated and do not require recalibration as they have fixed slits and optics. For those customers who wish to do their own calibrations, the AvaLight-CAL light sources can be used for recalibration purposes. For auto-calibration, AvaSoft-Fill provides a calibration procedure to make this easy.
-
Product
CableEye Tester Calibration Verification Board | Cable & Harness Tester
CB50
-
Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently.
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25F-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Single Or Dual Stream MIL-STD-1553A/BTest And Simulation Module For Standard Ethernet
ANET1553-x
-
The ANET1553-x is a member of AIM’s new line of Ethernet based modules for analysing, simulating, monitoring and testing MIL-STD-1553A/B databuses. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
Calibration Software
-
AMETEK Sensors, Test & Calibration
Our calibration software provides an easy way to calibrate gauges, RTD´s, thermocouples, transmitters, thermoswithes, and pressure switches. Complete a full calibration from entering the details of the gauge to printing out a calibration certificate. Reduce operating time by automating calibration procedures, reduce sources of error by automatically reading and storing values from the reference, and customize certificate templates to fit your needs.
-
Product
Acceleration Pickup Calibrator
VX-1100A
-
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
Product
Calibration Software
-
Calibration software is available to automate all or part of many calibration processes, manage calibration and asset data, and perform other useful tasks as well. Fluke Calibration offers a variety of market leading software applications in each of its product disciplines.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Trace-Level Photometric Ozone Calibrator
Model T703U
-
Teledyne Advanced Pollution Instrumentation
The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.
-
Product
Portable Vibration Calibrator
AT-2040
-
With AT-2040 you will find the features required for your application without having to install cumbersome and expensive addons. AT-2040 features a full-automatic sensitivity test mode, sensor simulation, power supply output for sensors that require voltage such as the 7310 and 991V aviation sensors, a built-in sensor charge amplifier for both single-ended and differential charge accelerometers, and a custom sensor input that can be configured to fit most accelerometers with a one to one cable.
-
Product
Acoustic Calibrator
CAL150
-
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
Product
Conformance Calibration Standard Test Card for ITF-14 (Interleaved 2 of 5) Symbol Verifiers
AI-CCS-ITF-14
-
This test card is ideal for testing verifiers, scanners, and other ITF-14 (Interleaved 2 of 5) barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
Calibration And Verification Instruments
-
The system of automatic calibration and verification consists of a computer of the operator's workplace and a control controller with a calibrator connected to it and a verified device. The device under test can have 4 to 16 working channels with a complicated circuit for connecting different types of signals: voltage, current, thermocouples, thermoresistance. The system allows a change in the set of operating ranges during calibration and calibration. The software development system used the LabVIEW development environment with the Real-Time module.
-
Product
Calibration Services
-
WTG's calibration package is more than just verification of performance specs. It is a complete package of services including inspection and maintenance. Our services uphold the value of the instrument and extend its lifetime.
-
Product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-R
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard Tests
-
The following list contains only the most important standards and does not claim to be complete.EN 60204-1 Electrical equipment of machinesEN 60335-1 Electrical appliances for household and similar useEN 50106 Sampling test, routine tests (in conjunction with EN 60335-1)EN 60598-1 LuminariesEN 60601-1 Medical electrical equipmentEN 60730-1 Automatic electrical controlsEN 61010-1 Measuring, control and laboratory equipmentEN 61439-1 Switch cabinet and switchgearEN 62368-1 Equipment for audio/video, information and communication technologyEN 62841-1 Hand-held electric toolsEN 50191 Erection and operation of stationary and non-stationary electrical test equipmentLVD Low V oltage D irective _
-
Product
Instrumentation Calibration Services
-
We offer a range of instrumentation calibration services for Kemo products in addition to other signal conditioning and sensors. We have many decades of experience in the manufacture, test and calibration of our instruments and those of our competitors. Please refer to the list below for an example of our calibration options, all equipment used within our calibration department is calibrated and traceable to a UKAS accredited National standard:
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I40-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Calibration Test Pumps
-
High-precision calibration & pressure testing is the key to success in the oil & gas, petrochemical, maritime, pharmaceutical and aerospace industries and the right calibration tools make all the difference. Ralston Instruments offers a wide array of intelligently designed, high-quality calibration test pumps that simplify complex calibration processes while providing fast, accurate results. All Ralston pressure test pumps are lightweight, extremely durable, and easy to disassemble and repair with standard hand tools. And for quick connectivity with the most effective results, they all come with Ralston Quick-test™ adapters for safe, stable, leak-free connections without the need for a wrench or thread tape.
-
Product
Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit
72-1015 CAL DU
-
The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
Standard Electromagnetic Vibrator
KD-9363-EM
-
King Design Industrial Co., Ltd.
The purpose of vibration testing is to make a series of controllable vibration simulation in lab, no matter generated by natural or man-made vibration environment; such as waves, tidal flaps, wind, earthquake or rain and so on. It is to test if the product is capable of sustaining the vibration environment exerted from transporting or usage along its effective life cycle; and certify the standard of design & functional requirement of product. The value of vibration testing is to confirm the reliability of products and effectively screen out the bad products in factory; avoiding damages occurred at arrival; and to assess the failure analysis on the non-performing products; expecting to reach a high standard, high-reliability products. The vibration test stresses on the continuity and fatigue; and contributes to the understanding of product’s status under vibration circumstance in a normal environment; and avoids the product’s unpredictable damage caused under certain vibrating frequency for a long time.
-
Product
Calibration Kit
N611
-
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I8-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T80
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40A
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I40-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02