Shielding
Protects against or confines electromagnetic or ionizing radiation.
See Also: Shielding Effectiveness
-
Product
Monopole Antennas
-
Our Monopole Antennas provide superior performance in electric field measurements. The Active Monopole Antenna can drive any receiver with 50W input impedance and will perform FCC, MIL-STD and TEMPEST tests. The passive rod is used for transmitting, to perform shielding effectiveness and immunity testing.
-
Product
Dual RF Shielded Test Enclosure
JRE 0814-2R
-
Containing all the capability of the larger JRE enclosures, the rack mounted 0814-2R is ideal for testing devices with a tall form factor. Two independent 0814 series enclosures are mounted in one 19 inch rack. Two shielded vents provide excellent cooling and optional fan(s) are available for those hot products. Tough 'honeycomb' vents maintain shielding effectiveness throughout the frequency range. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness.
-
Product
VXI C-Size Blank Board
115250
-
* C-Size blank PC Board for mounting devices, modules or circuits.* Includes VXIbus P1 and P2 connectors and decoupled power pads.* Includes pads for all VXI bus signals.* Includes pad patterns for common front panel connectors, LEDs, and a Reset Switch.* Includes CAD Design aids for Schematic Capture, PC board layout and front panel machining.* Use with ICS 1, 2 and 3-slot wide Module Shield Kits to create a complete enclosed module.* Use with ICS Front Panel Kits to add a front panel and ejectors to the blank board.
-
Product
Furnace and Electrical Inspection Camera
FLIR GF309
-
The FLIR GF309 is designed for high temperature industrial furnace applications. These infrared cameras are ideal for monitoring all types of furnaces, heaters, and boilers, particularly in the chemical, petrochemical, and utility industries. Custom-built to see through flames, the FLIR GF309 also features a detachable heat shield designed to reflect heat away from the camera and camera operator, providing increased protection.
-
Product
Near Field Probes 30 MHz up to 3 GHz
RF1 set
-
The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
Product
Gross Gamma Screening System
-
The Gross Gamma Screening system is intended for the rapid screening of urine samples for the presence of elevated radioactivity in a post-radiological event scenario. This system allows up to eight urine samples to be counted simultaneously in discretely shielded 3” x 3” NaI Well radiation detectors to quickly identify elevated radioactivity from personnel in the exposed population. This screening process provides critical information to Emergency Response Agencies and is accomplished with minimal operator training.
-
Product
Standard VXI Module Shield Kits With Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Clamshell design fits C-size modules with 96-pin connectors.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Address switch opening on component side shield.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Forced Air Cryogenic Cooling
FixTreme TE
-
FixTremeTE is a cost-effective standalone alternative to mechanical or forced air cryogenic cooling. When paired with a Testforce dbGuard Series RF shielding test enclosure, performing at temperature RF & microwave functional testing is simple.
-
Product
System Components
-
For demanding computational tasks, Rohde & Schwarz offers the versatile, flexible equipment you need for everyday use – from the system controller and switch unit to the test chamber. All feature excellent EMC shielding, reliable test results and modular solutions.
-
Product
Mini Coax, Contact, ITA, RG178
610103130
Coax Contact (ITA)
Primary mating contact 610104141. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
Product
Coax, Contact, ITA, 20/26 GHz, 3.5MM, w/ SMA Adapter, 90 Series Modules only
610102134
Contact Adapter (ITA)
Coax, Contact, ITA, 20/26 GHz, 3.5MM, with SMA Adapter (90 Series modules only)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination 3.5mm compatibleInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications 3.5mm compatibleEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MΩ min.
-
Product
Cable Fault Testers
-
*Compact and lightweight solution for underground cable testing*DC Hi-Pot test of de-energized, shielded underground primary cable*No external power required - self-contained 8kVDC voltage source*Can be used up to a distance of 1500 ft (457m)*Clear and simple test results - analog bar graph and indication of good or faulted cable*Safety feature - measures AC voltage before converting to a DC voltage tester*Lightweight, single hot stick operation for testing cable
-
Product
Original VXI Module Shield Kits
11399x Series
-
* Clamshell design fits C-size modules with 96-pin connectors.* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Component side shield has an address switch opening and non-rectangular mounting hole pattern.* Complimentary layout support includes PCB design template and CAD layout files.* RECOMMENDED FOR LEGCY APPLICATIONS ONLY due to its non-rectangular hole pattern.
-
Product
X13 GPIB Cable, MicroD25 to Shielded cable/Standard connector, 2M
183285-02
GPIB Cable
24-Pin Male/Female GPIB to 25-Pin Male Micro D-SUB GPIB Cable - The 24M-24F-MicroDB25M X13 GPIB Cable, sometimes referred to as the X13 cable, connects your system to GPIB devices or interfaces for instrument control. This standard shielded cable can connect PXI Controllers to instrument control devices and is offered in different lengths.
-
Product
MP CI set
-
The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)
-
Product
Shield Level / Pathloss Equipment
SG1000B/PR1000A
-
The SG1000 Signal Generator and PR1000A Preamplifier have been designed to simplify the measurement of shielding integrity in a shielded enclosure. When coupled with a high stability spectrum analyzer and an appropriate selection of test antennas, the SG1000/PR1000A combination can measure shielding effectiveness at all of the NSA 94-106 (supersedes NSA 65-6) defined test frequencies from 1 kHz to 10 GHz.The PR1000A amplifies the received signal from the test antenna and overcomes the high noise figure of the companion test receiver or spectrum analyzer. The PR1000A will ensure that the system noise figure will be less than 4.5 dB at all test frequencies from 1 kHz to 10 GHz. When used with a spectrum analyzer measurement bandwidth of 100 Hz, the system exhibits a sensitivity of -150 dBm at the test antenna output.To overcome high cable loss between the test antenna and the PR1000A assembly at 10 GHz, a remote low noise pre-amplifier (Praxsym PN 310-010091-001) is mounted directly onto the 10 GHz antenna.
-
Product
SHC68-68-EPM, 68-Pin Male VHDCI to 68-Pin Female D-SUB, Twisted Pair, Shielded Multifunction Cable, 0.5m
192061-0R5
Multifunction Cable
Connects to DAQ devices and modules, terminal blocks, bare wires, or other accessories. The multifunction cable models include a variety of industry-standard front- and back-end connectors, such as 68-pin VHDCI, 96-pin SCSI, and 68-pin SCSI. Cable selection depends on the connector types and requirements of the hardware you’re connecting to and the environment in which you’re using the cable. Some cables are internally twisted and shielded to more effectively reject ambient noise than an ordinary shielded cable. These cables are designed to work with high-performance NI devices.
-
Product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
-
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
Product
SCB-100 Noise Rejecting, Shielded I/O Connector Block
776990-01
Terminal Block
100-Pin Female SCSI to 100-Pin Female Screw Terminal, Desktop Mount Terminal Block - The SCB-100 is a shielded I/O connector block for interfacing I/O signals to NI data acquisition devices with 100-pin connectors. Combined with the shielded cables, the SCB-100 provides rugged low-noise signal termination.
-
Product
ITA, ICon, EMI-Shielded, With Threaded Coupling Adapter And Protective Cover
410123102
ITA
The iCon EMI has many of the standard features of the iCon, in addition to Electro-Magnetic Interference protection. The EMI shielding effect on the iConEMI ITA is provided by the stainless steel fibers in the removable plastic cover and threaded metal coupling adapter. The opening of the threaded coupling adapter provides clearance for a maximum cable bundle with an oblong bushing effective diameter of 1.37 in. Protective cover included.
-
Product
Power Sensor and SNS Noise Source Cables (3 m/10 feet)
11730B
Power Sensor
The Keysight 11730 series power sensor cables are used with the 8480 and E-series power sensors (except the E9320 family of peak and average sensors). These cables are designed to reduce RFI effects on low power readings with an improved shielding design in the cable itself. Cables may be ordered individually or in pairs in any combination desired for single and dual-channel measurements.
-
Product
PXI High Voltage Switching Modules
-
These high voltage relay switching modules provides solutions for uncommitted relay, matrix and multiplexer applications that need to switch voltages up to 1000VAC. The design of these high voltage relay modules ensures they can withstand high common mode voltages and a protective safety cover is used to shield the switching components.
-
Product
Micro Coax, Patchcord, ITA, 36", RG316 Double Shield Tan, Single Ended
7-367117000-036
Coax Patchcord
Micro Coax, Patchcord, ITA, 36", RG316 Double Shield Tan, Single Ended
-
Product
Molded Inductors
-
Molded inductors are constructed by pressing or molding a magnetic material around a pre-wound coil and lead-frame to form the inductor. Our molded inductors provide a fully shielded, high energy density, soft saturation solution for applications up to 110Apk. The construction enables low profile solutions in a cost effective and robust solution that minimizes acoustic noise. We offer a high saturation current series (commercial and automotive, -40C to 125C) and a low DCR series (automotive, -55C to 155C) in a wide range of platforms from 4x4x1.2mm up to 24x24x13mm.
-
Product
SparkFun Spectral Sensor Breakout
AS7262 Visible (Qwiic)
-
The SparkFun AS7262 Visible Spectral Sensor Breakout brings spectroscopy to the palm of your hand, making it easier than ever to measure and characterize how different materials absorb and reflect different wavelengths of light. The AS7262 Breakout is unique in its ability to communicate by both an I2C interface and serial interface using AT commands. Hookup is easy, thanks to the Qwiic connectors attached to the board --- simply plug one end of the Qwiic cable into the breakout and the other into one of the Qwiic Shields, then stack the board on a development board. You’ll be ready to upload a sketch to start taking spectroscopy measurements in no time.
-
Product
Type 11C, CPCI, Rackmount/Wallmount
11C-CPCI
-
Elma Type 11C family of enclosures provides a high quality, cost effective pre-plated steel platform. Designed to IEEE 1101.10/.11 standards, Type 11C enclosures give advanced EMC shielding protection.
-
Product
Multimeter Network Tester
VA16
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Network Cable test (RJ45): Tests for open circuits, shorts, miswires, reversals, and split pairs SHIELD detection tests a cabl
-
Product
SHH19-MH19-AUX Shielded Single-Ended Cable, 1m
784091-01
Cable Assembly
19-Pin Male Mini-HDMI to 19-Pin Male HDMI Shielded Digital Cable.
-
Product
SHC68M-68F-RMIO, 68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Multifunction Cable, 2m
189588-02
Multifunction Cable
68-Pin Male VHDCI to 68-Pin Female D-SUB, Shielded Multifunction Cable - The SHC68M-68F-RMIO Cable, sometimes referred to as SHC68-68-RMIO, connects to the terminal block of a multifunction reconfigurable I/O (RIO) device. The SHC68M-68F-RMIO Cable is offered in different lengths.
-
Product
Cable Tester
CT100
-
The intelligent, CPU-controlled CT100 accepts virtually any connector type: XLR, mono and TRS phone ( 1 /4 ", 1 /8 ", TT), RCA and MIDI. It shows which input pin is connected to which output pin. Separate LED's indicate proper shield connection and phantom power presence. The CT100 also offers an installed cable test mode and a continuity check plus a test tone generator.