Product
Contactless Laser Extensometers
-
Jinan Testing Equipment IE Corporation
Model LE-05 and LE-15 extensometers measure strain optically, without contacting the specimen, using laser diode technology. The extensometers are self-contained and portable. They may be interfaced with a variety of testing machines and data acquisition systems using the ±10V analog output or bi-directional RS-232 serial port. Operation may be local or remote. A digital display is included. The scanning beam is always perpendicular to the specimen, unlike most laser extensometers. This eliminates errors when viewing through windows in chambers. It also minimizes sensitivity to the distance between the extensometer and the sample. Because the unit measures reflected light, no receiver is required behind the sample.
-
Product
High Elongation Extensometers
Model 3800
-
Jinan Testing Equipment IE Corporation
The main body of this unique extensometer remains stationary during testing, held in position by the adjustable magnetic base included. Only the very light, small traveling heads move as the sample elongates during a test. These attach to the sample with small spring clips. Each head pulls a cord out from the extensometer as the head moves. These models use high precision, low friction potentiometers, and, as a result, have a wide range of factory selectable outputs. The extensometer is driven by an excitation voltage and has output proportional to the input. They can be provided with high level outputs (approximately 2-8 VDC) or ones that mimic strain gaged devices (2-4 mV/V). When set to mimic strain gaged extensometers, the Model 3800 can be used with virtually any signal conditioning electronics designed for strain gaged sensors. The potentiometers employ a hybrid wire wound around conductive plastic, which provides excellent long term stability. The output from the extensometer is readily interfaced with most existing test controllers, and may be directly input to data acquisition systems and chart recorders. Please let us know at the time of order what type of output and connector you require.
-
Product
Miniature Transverse (Diametral) Extensometers
Model 3475
-
Jinan Testing Equipment IE Corporation
A miniature extensometer designed for general purpose transverse or diametral strain measurements on small or thin specimens. May be used simultaneously with the Model 3442 miniature axial extensometers or the Model 3542 axial extensometers.
-
Product
Submersible Extensometers
Model 4030
-
Jinan Testing Equipment IE Corporation
The Model 4030 extensometer uses a special LVDT-like sensor to measure strains on samples submersed in water or other compatible liquids. The unit is provided with the signal conditioning electronics. The extensometer is a semi-custom design, which is available in smaller measuring ranges up to 5 mm (0.2 inches). Clip-on (COD) style designs are also available.
-
Product
Bi-Axial or Axial Averaging Extensometers
Model 3560
-
Jinan Testing Equipment IE Corporation
This extensometer is ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests like determining Poisson’s ratio. The Model 3560BIA uses a design unique to Epsilon, where the knife edges remain parallel during the displacement. This approach greatly reduces crosstalk between axes and allows use on round or flat specimens with equal ease. These extensometers are very easy to mount. Integral springs hold the unit on the test sample. The parallel multiple flexure design makes these units very durable.The Model 3560AVG reads axial strain only as a single averaged output. It may also be supplied with two independent outputs, one measurement from each side of the specimen. This set-up is most commonly required when an indication of specimen bending is desired. The second version, the Model 3560BIA, includes both the averaged axial strain and the transverse strain. Again, this may also be configured as dual independent axial readings, which results in a three channel extensometer.The Model 3560 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Averaging Axial Extensometers for Large Compression Samples
Model 3542RA
-
Jinan Testing Equipment IE Corporation
Designed primarily for compressive strength tests on rock, concrete and other large compression samples, this model measures axial strain on opposite sides of the test specimen, and the output is an average of the two readings. Gauge lengths from 1 to 8 inches (25 to 200 mm) and measuring ranges from 0.050 to 0.250 inches (1.2 to 6 mm) are available.
-
Product
Long Travel Extensometers
-
The first type is specifically aimed at the plastic and rubber industries to provide accurate readings of strain and extension over a large extension range. The unit, incorporating two clamping arms and precision potentiometers, produces a DC voltage proportional to the distance between the arms. This generates accurate readings of percentage strain and allows additional parameters such as yield point and break points to be calculated when used with NEXYGENPlus software.
-
Product
Deflection Gauge Extensometers
-
We supply a wide range of deflection gauge extensometers ideal for measuring deformation in three and four point bend tests and in compression testing applications.
-
Product
Axial Torsional Extensometers
Model 3550
-
Jinan Testing Equipment IE Corporation
Designed for simultaneously measuring axial and torsional deflections on specimens tested in axial/torsional machines.
-
Product
Contactless Video Extensometers
-
Jinan Testing Equipment IE Corporation
Deformation measurement of samples during material testing with use of the Video extensometer MercuryRT allows applying multiple virtual probes (Movement Sensors)on markers and advanced image featuresto be tracked, including the natural pattern of the sample surfaces.The common resolution of standard system is within 500 nm and 5 m. The system fulfils class 0.5 or B-1 of classification according to ISO 9513 and ASTM E83. In certain camera use case, the system resolution reaches the level of 100 nm - 500 nm and system fulfils the class 0.2. The strain resolution can reach 10 microstrains. Material testing,Component testing ,FEA validation,Vibrography .
-
Product
Transverse and Diametral Extensometers
-
3 models cover most any test requirement and can be used with axial extensometers at the same time. Miniature and standard units, also r-value units. Available options cover temperatures from -265 to +200 C (-450 to +400 F).
-
Product
High Temperature, Low Strain, Extended Performance Capacitive Extensometers
Model 7650A
-
Jinan Testing Equipment IE Corporation
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
-
Product
Miniature Axial Extensometers
Model 3442
-
Jinan Testing Equipment IE Corporation
Weighing as little as 8 grams, these miniature extensometers are designed to have very low operating force with minimal specimen influence. All use an improved version of Epsilon’s dual flexure design which makes them very rugged for their size. With a module height of 15.2 mm (0.6 inches), they will fit in the limited space between grips that is typical with small test samples. Gauge lengths can be as short as 3 mm or as long as 50 mm. A newly designed gage setting pin and assembly allows the gauge length to be set accurately and repeatably to ASTM and ISO requirements for all gauge lengths. Reengineered quick attach wire forms provide simple and secure specimen attachment. Wire forms for round and flat specimens are included, as well as flat, 3-point, and vee knife edges. The wire forms may be removed to enable mounting using elastic bands or springs. A tethering attachment point provides fall protection and enables counterbalancing of the extensometer’s weight when testing delicate specimens.Model 3442 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller and Epsilon will equip the extensometer with a compatible connector wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of solutions for signal conditioning and connection to data acquisition systems, chart recorders, or other equipment.
-
Product
High Temperature Axial Torsional Extensometers (1200 C or 1600 C)
Model 7650
-
Jinan Testing Equipment IE Corporation
Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.
-
Product
Rebar Coupler and Rebar Splice Extensometers
Model 3567
-
Jinan Testing Equipment IE Corporation
Extensometers for measuring elongation of rebar coupler, splicer, and sleeve assemblies. Use for tension, cyclic, slip, and differential elongation tests.
-
Product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
-
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Diametral Extensometers for Rock and Concrete Testing
Model 3975
-
Jinan Testing Equipment IE Corporation
Designed for accurate measurement of small diametral strains such as those required to determine Poisson’s ratio of rock, concrete and asphalt samples. The units are designed to be used in conjunction with the Model 3542RA axial averaging extensometer.
-
Product
Long Gauge Length Axial Extensometers
Model 3542L
-
Jinan Testing Equipment IE Corporation
The dual flexure design makes the 3542L very rugged and insensitive to vibrations. These extensometers are designed for testing a wide range of materials including metals, plastics, composites and ceramics. Epsilon’s Model 3543 is recommended for applications requiring long gauge lengths and larger measuring ranges.The Model 3542L comes standard with Epsilon’s quick attach kit, making it easy to mount the extensometer on the test specimen. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The 3542L extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Averaging Extensometers for ASTM D5656 Shear Tests
Model 4013
-
Jinan Testing Equipment IE Corporation
The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Contacting Extensometers
-
The contacting extensometers are designed for accurate strain and extension measurement of a material up to a maximum sample thickness of 25 mm.
-
Product
Extensometers for Creep Compliance and Tensile Strength Testing of Asphalt
Model 39
-
Jinan Testing Equipment IE Corporation
Designed to many of the needs for testing asphalt core samples in 4 and 6 i ch diameters. The unit meets test method requirements for strain measurement developed under the U.S. Federal Highways SHRP program.
-
Product
High Temperature Self-Supporting Furnace Extensometers (1200 C)
Model 3448
-
Jinan Testing Equipment IE Corporation
Epsilon developed this unique high temperature extensometer for testing metals, ceramics, and composites at the high temperatures produced by furnaces and induction heating systems. A combination of features make these extensometers easier to use and better in performance than other similar high temperature extensometers.The units are held on the specimen by light, flexible ceramic fiber cords. These make the extensometer self-supporting on the specimen. No furnace mounting brackets are required. The side load on the test sample is greatly reduced because of the self-supporting design and light weight of the sensor. Most materials testing furnaces with a side cut-out for an extensometer will readily accept a Model 3448. For induction heating systems, a different ceramic cord placement allows the extensometer to easily pass between the coils.The combination of radiant heat shields and convection cooling fins allow this model to be used at specimen temperatures up to 1200℃ (2200°F) without any cooling. An optional tiny air fan does enhance stability at the highest temperatures and is recommended for the highest accuracy and for tests with small elongations. The fan comes with a magnetic base for support so it can be mounted at any convenient location near the extensometer. Fan cooling is not generally needed for induction heated systems. High purity alumina ceramic rods are used. These are available in lengths as required to fit your furnace. A spare set is included with every extensometer. Specify chisel, vee chisel or conical contact points as desired.Most units operate equally well in tension and compression. Thus tensile, compression and cyclic tests like low cycle fatigue can all be performed with a single unit.For vacuum furnaces, special models are available. Epsilon can also provide a radiant heat transfer cooled version. This requires that the extensometer module be surrounded by a water cooled enclosure with a front slot for the ceramic rods.
-
Product
Video Extensometers
-
AMETEK Sensors, Test & Calibration
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
Product
High-Temperature Extensometers < 1000°C Capacitive
2632 Series
-
Is typically used in hot tensile applications with tube type furnaces and consist of a separate measuring unit and suspension arm assembly. The measuring unit uses an LVDT with a fixed travel that remains outside of the furnace, the arms are located mostly inside of the heating system and attach the specimen to the measuring unit.
-
Product
Automatic Extensometer
SIE-560A/560SA
-
To determine the suitability of a material for an application where it is under load, measuring its elongation is important. Measuring elongation enables determination of the elastic modulus (reversible elongation in the elastic region) by measuring the small initial elongation range, and determination of elongation at specimen failure, by measuring larger irreversible elongation in the plastic region. Shimadzu’s SIE-560A series automatic extensometers accomplish both of these measurements with high accuracy, and provide automated functions that increase testing efficiency and test reproducibility. Ideal for testing a wide variety of materials, including metallic materials, plastics, and composites, the SIE-560A series complies with ISO 527, JIS K 7161, and ASTM D638 standards for plastics tensile testing. In addition, the SIE-560A series supports strain-rate controlled metallic material tensile testing measurements specified in ISO 6892, JIS Z 2241, and ASTM E4
-
Product
High Temperature Furnace COD Gages (1200 C or 1600 C)
Model 3548COD
-
Jinan Testing Equipment IE Corporation
These COD gages mount on a water-cooled bracket, which is mounted on the furnace side cut-out or with optional load frame support brackets. The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. Mounting brackets may be integrated with the furnace cut-out. Epsilon can also provide optional load frame mounting brackets to fit your test frame. Contact edges on the test sample should be somewhat rounded (not sharp knife edges) for best performance with this model. The Model 3548COD extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Long-Travel Extensometer For Soft Materials
DSES-1000
-
A Long-Travel Extensometer That Is Now Easier to Use and Even More Precise The DSES-1000 is a long-travel contact-type extensometer able to measure displacement up to the breakpoint in tensile tests of rubber and other soft materials. The upper and lower arms are clamped to respective gauge positions using a simple single operation, with each arm tracking sample elongation independently.
-
Product
Rock, Concrete and Asphalt Extensometers
-
7 models cover axial, circumferential and diametral testing on aggregate material.
-
Product
Non-Contact Digital Video Extensometer
TRViewX
-
TRViewX is an advanced non-contact extensometer that offers high-measurement accuracy, is capable of measuring width changes, and is applicable to a wide variety of materials testing applications. In particular, due to the non-contact design, TRViewX is perfect for measuring films, foils, and other thin or narrow materials without affecting the specimen during testing. Furthermore, TRViewX can be used to measure displacements during atmosphere-controlled testing in a thermostatic chamber. TRViewX provides high-accuracy measurements in accordance with ISO 9513 Class 0.5 and JIS B 7741 Class 0.5 for elongation measurements and ISO 9513 Class 1 and JIS B 7741 Class 1 for width measurements. It is compliant with plastic tensile testing standards, including ISO 527, JIS K7161, and ASTM D638, even supporting 75 mm gauge length specimens (type A1 specimens) specified in ISO 527 and JIS K 7161.
-
Product
Deflection Gauge Extensometers
-
AMETEK Sensors, Test & Calibration
We supply a wide range of deflection gauge extensometers ideal for measuring deformation in three and four point bend tests and in compression testing applications.