Hilkar
Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkiye
-
Product
Resistive Load Banks
R Series
-
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
Product
Air Core Shunt Reactors
-
Shunt Reactors act as absorbers of reactive power to increase energy efficiency of the power system. Shunt Reactors are inductors that are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. The shunt reactors provide inductive compensation.
-
Product
Reduced Voltage Motor Starting Panels by Reactors
-
A method to limit motor starting current is a series reactor. Iron core or air core reactors can be used for starting purposes. If an air core is used for the series reactor then a very efficient and reliable soft starter can be designed which is more suitable for high MW ratings of synchronous/induction motors at MV levels. The reactors are designed with taps.
-
Product
LCL Filters
-
LCL Type Harmonic Filter Modules are used to filter out the input current harmonics of the Motor Drives having six-pulse diode/thyristor rectifiers, where harmonic current distortion exceeds the limits defined in standards.
-
Product
Radiator Mounted Load Banks
RD-Series
-
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
Product
Explosion-Proof Heaters
-
Explosion-Proof Heaters (ATEX certified) provide neutral convection solutions of heating for electrical equipments in hazardous industrial locations where potential for explosion exists due to the presence of flammable gases, vapors, powder-metals or dusts.
-
Product
Neutral Grounding Resistors
NGR
-
Neutral Grounding Resistors (NGRs) are used to limit the fault current for safety of equipment and personnel in industrial systems.
-
Product
Motor Starting Auto-Transformers
-
Motor Starting Auto-Transformers reduce the inrush current by stepping down the applied voltage during the start-up operation of induction and synchronous motors.
-
Product
Generator Neutral Grounding & Leads Cubicles
-
Generator Neutral Grounding Cubicles are designed to minimize fault damage incurred by generators, maintain sufficient fault detection and improve power system reliability. Generator Neutral Grounding and Lead Cubicles are manufactured as for IEEE or IEC standards.
-
Product
Motor Starting & Control Resistors
-
Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current. Motor Starting Resistors are necessary because the self resistance of a motor armature is very low. When the voltage is first applied, excessive current will flow. For limiting this current, since there will be no resisting back electromotive force (emf),some series resistance can be added to the armature windings.
-
Product
Medium Voltage Iron Core Oil-Immersed Shunt Reactor
-
Iron core Oil-immersed Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system.
-
Product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
-
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
Product
Anti-Islanding Load Banks
AI-Series
-
AI-series anti-islanding load banks containing purely resistive, inductive, or capacitive load, have segmented combination control of power input, and can simulate a variety kinds of power loads to meet the grid-connected inverter full load test requirements.
-
Product
Inductive Load Banks
L-Series
-
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
Product
Air Core Neutral Grounding Reactors
-
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.