Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkiye
-
Product
Air Core Smoothing Reactors
-
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems.
-
Product
LV Iron Core Motor Starting Reactors
-
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
Product
Sensing Resistors
Resistive Voltage Dividers
-
NGR Sensing Resistors are attached in parallel to the neutral grounding resistor. The sensing resistor allows a protective relay to detect a resistor failure in a continuous manner. Sensing Resistors are used in combination with neutral grounding resistor monitor relays. The relay measures neutral grounding resistance, neutral grounding resistor current and neutral to ground voltage. The relay continuously measures neutral grounding resistor ohmic value in an unfaulted system and it trips on if neutral grounding resistance varies from its calibrated value.
-
Product
Reduced Voltage Motor Starting Panels by Auto-Transformers
-
Reduced Voltage Motor Starting Panels are designed for starting of squirrel cage induction and synchronous motors. A RVMS Panel reduces the torque by temporarily reducing the voltage and/or current input. It reduces voltage applied to the motor during start up causing lower starting currents from the connected grid.
-
Product
LV Iron Core Line & Load Reactors
-
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Product
Sine Filters
-
Sine Wave Output Filter Modules provide satisfactorily smoothed sinusoidal waveform with low residual ripple form square waveform with high voltage spikes, present at the output of motor drives.
-
Product
Iron Core Current Limiting Reactors
-
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
Product
Slip-Ring Motor Starting Panels
Rotor Starter
-
The Slip-Ring Motor Starters are based on the series of resistors that are applied to the rotor circuit to control the speed/torque characteristics of the motor. Rotor starters are mainly used for the motor starting applications requiring high-starting torque like loaded belt conveyors in mining industry. By external resistors, it is possible to shift the motor maximum (break-down) torque up to starting torque point for motors under heavy loads during start-up. The resistors are splitted into some steps and controlled via contactors by motor starting control system. As the motor speed increases, the external rotor resistors are eliminated by shorting contactors until all external resistors are shorted out.
-
Product
Air Core Line & Load Reactors
-
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
Product
Turn-Key Short Circuit Laboratories
-
For low and medium voltage switchgear including :*Circuit breakers*Contactors*Disconnect switches*Fuses*Miniature circuit breakersApplied tests for low and medium voltage switchgear :*Dielectric withstand test*Impulse withstand test*Breaking capacity test*Mechanical life testElectrical life test*Over load performance test*Short circuit breaking capacity test**Short time short circuit impulse current test*Temperature rise test*Operation performance testTests for low & medium voltage panels :*Short time short circuit impulse current test*Dielectric test*Impulse withstand voltage test*Temperature rise test
-
Product
Air Core Harmonic Filter Reactors
-
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Harmonic Filter Resistors
-
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Anti-Condensation Heaters
-
Anti-Condensation Space Heaters are designed to maintain the temperature of an electrical enclosure. Anti-Condensation Heaters are used for elimination of water vapor contained inside the enclosures. They also provide frost protection by keeping the internal temperature of electrical enclosure above the freezing temperature. The Anti-Condensation Space (Panel) Heaters prevent condensation through convection.
-
Product
High Resistance Neutral Grounding Devices
-
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
Product
Motor Termination Units
-
Since the rise time of IGBTs are in the range of a few tens of nanoseconds (between 50ns-200ns), even short cables between PWM motor drives and motors cause voltage doubling at the motor terminals due to Travelling Wave Phenomenon as in transmission lines. The insulation of motor windings are prone to failure due to high voltage spikes if necessary precautions are not sufficiently taken. RC Type Output Filter Modules reduce these high voltage spikes to protect motors by connecting to stator terminals.