Primary Current Injection Test
-
Product
Current Transformers
-
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
Product
Current Probe
-
Beijing GFUVE Electronics Co.,Ltd.
Used to measure control currents for relays in electronic circuits and in evaluation testing of capacitors' current characteristics.
-
Product
Conformance Test System
TS-RRM
Test System
The R&S®TS-RRM 5G and LTE test system is a test solution for running 5G NR and LTE inter-RAT RRM test cases for certification of wireless devices.It is a fully automated conformance test system for running validated RRM conformance test cases. In addition to the RRM test cases required by GCF/PTCRB, the R&S®TS-RRM also supports carrier acceptance specific RRM tests.
-
Product
Current Injection Sets
-
Built in c based Time Interval Meter measuring from1 millisec to 9999 sec. Panel with easy and clear legends to read. Continuosly variable outputs. Auto Cut-off & output isolated. Self sensing of contacts i.e. NO or NC Potential free star stop signals Available in Portable / Lab type models with metal cover
-
Product
6TL22 Off-Line Testing Platform
H71002200
Test Platform
Learn about our Build to print service for Test Platforms. The 6TL22 Platform is a perfect base for the conception of a real modular Automatic Test Equipment for low to mid manufacturing volumes.A system designed around the 6TL22 is simple, easy to maintain and cost effective. The rack is prepared for the direct integration of the three platform based receivers from Virginia Panel, the S6, G12 and G12X.
-
Product
Current Probe
LFR
-
Power Electronic Measurments Ltd
The LFR is ideal for power quality applications. It has a small, predictable phase error, for power measurements at 45/65Hz. The wide bandwidth allows accurate measurement up to and even above the 400th harmonic.
-
Product
High Current capacity testing from Intelligent Charging
CT75A
-
A UK-based helicopter manufacturer wanted high capacity testing capability for their helicopter batteries and came to Intelligent Charging for a Special Unit. As a result of the above requirement, Intelligent Charging designed and built this new capacity testing unit to add to our extensive range of intelligent battery charging and capacity testing products. With up to 100.0A capacity testing capability this model will satisfy the most demanding aviation battery.
-
Product
Brute High Current Probe
P4301-2R
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Eddy Current Sensor
eddyNCDT 3001
-
The eddyNCDT 3001 is a new, efficient eddy current sensor whose compact dimensions have to date only been reserved for inductive sensors and proximity sensors. The temperature-compensated design provides high stability even in fluctuating ambient temperatures. The eddyNCDT 3001 comes with integrated electronics, offering an outstanding price/performance ratio and easy operation. The eddyNCDT 3001 eddy current sensor is ideally suited to OEM integration and machine building applications. The sensor is factory-calibrated for ferromagnetic and non-ferromagnetic materials, which eliminates the need for field calibration of the sensor. The eddyNCDT 3001 is available with connector or with integrated cable. A robust design combined with the eddy current measuring principle enables measurements in harsh industrial environments (oil, pressure, dirt). In addition, the eddyNCDT 3001 is suitable for offshore/marine applications (salt water).
-
Product
Current Probe
PA-699
-
*High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability
-
Product
FPD Tester Model
27014
Test Platform
Chroma 27014 Flat Panel Display Tester is a complete testing solution that meets the Liquid Crystal Module testing requirements of production line. With integrated video generator, multi-channel precision power supply and process control unit, the system allows a complete test of signal, pattern and electrical parameters of LCM through a PC or remote control box.
-
Product
High Current Probe/DMM
655
-
Another great tool for all around electrical troubleshooting. The #655 is ideal for all high current applications, especially starting and charging diagnostics. The #655 can measure up to 1000 Amps AC or DC. Unit features built-in degrees F and C temperature readings.
-
Product
Current Caliper
KH23101
-
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
Product
20Hz Injection Kit Monitoring System
-
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
Product
VLSI Test System
3380P
Test System
The 3380D/3380P/3380 test system have 4 wires HD VI source and any-pins-to-any-site high parallel test (multi-sites test) functions (512 I/O pins to test 512 ICs in parallel) that can meet the upcoming higher IC testing demands.
-
Product
Eddy Current Test System
CIRCOGRAPH® Product Family
-
Foerster Instruments, Incorporated
The CIRCOGRAPH eddy current test system with rotating probes guarantees maximum detection sensitivity for exposed longitudinal surface defects on bright material. The test system is primarily used for wire drawing machines, Cu tube rewinders, and finishing sections in the bright steel sector. The individually tailored test systems by FOERSTER can be fitted with rotating sensors or CIRCOSCAN rotating discs. They scan flat and profiled material, e.g. when testing rails and billets.
-
Product
Primary Reference Generator
VCH-001
-
The Primary Reference Generator (PEG) VCH-001 is designed to generate the highest accuracy clock signals in a digital communication network. Main areas of application: – synchronization in telecommunication networks.
-
Product
Current Sources
-
Innovar Current Sources are the standard in the circuit breaker industry. Our Current Sources supply regulated current from 1 amp to 100,000 amps with incredible accuracy, along with providing a full set of features that is unmatched by any other Current Source in the market.
-
Product
CP400X, 400 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784254-01
High Current Probe
The CP400X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 2 meters in length. The CP400X attaches to BNC connections on both the signal input and instrument sides.
-
Product
Current Meter
Model 106
-
The Model 106 is the ideal instrument for coastal and estuarine applications and other light-duty survey work.
-
Product
Fuel Injection Pressure Tester with Quick Couplers
53900
-
Quick couplers provide for fast and easy hook-up. Kit contains adapters to test all GM vehicles with Multi-port and some Throttle Body Injection (TBI). Tests all Chrysler cars with Multi-port turbos and some TBI. Use on Ford older TBI systems not equipped with small Schrader test valve. Includes Large Gage with hang-up hook calibrated from 1-100 PSI (0-7.0 BAR). Supplied with instructions in a vinyl pouch.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
Electronic Fuel Injection & Ignition Spark Tester Kit
36310
-
Quickly diagnose "no start" and engine miss conditions in the electrical fuel injection and spark plug circuits. Analyze rough running engines. Contains Cat. No. 36300, Noid Light Set to test electronic fuel injection signals and the Cat. No. 23900, In-Line Ignition Spark Checker to trouble shoot the ignition system (Shows a duplicate view of the ignition spark). Supplied with Noid Lights to check Bosch PFI, Ford TBI, Geo TBI, GM PFI, GM SCPI and GM TBI.
-
Product
Sealed Beam Bulb Testing System
H710019SSL
Test Platform
EOL test for manufacturing of bulbs with LED for applications requiring to ensure watertightness: vehicles, marine, swimming pools, operating rooms, classified areas (Ex Zone), etc. The test system checks in a short time all the light and electrical characteristics of the bulb. A high precision Micro Leakage Meter also checks that there are no leaks between the environment and the inside of the bulb. The test results are recorded on the PC and can be printed on a quality control label attached to each unit.
-
Product
NI-9265, 4-Channel C Series Current Output Module
779334-01
Current Output Module
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
Current to Digital
-
Analog Devices’ breakthrough current-to-digital converter technology is backed by award winning expertise to help solve your medical, industrial, and security application needs. Our high speed, high resolution ADC modules enable improved CT scanner data acquisition, photodiode sensors and power monitoring, spectroscopy, and high channel count data acquisition systems.
-
Product
30 A Current Shunt
34330A
-
Measure current safely with this precision 0.001 ohm resistor housed in a plastic case surrounded by epoxy.
-
Product
Primary Test Equipment
LET-2000-RD
-
It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.
-
Product
Fuel Injection Pressure Tester Bleed-Off Kit
37400
-