Power Factor
measures true power over apparent power.
-
Product
Light Compensation Capacitor
CBB80
-
Designed for lighting applications such as fluorescent lamps,high-pressure mercury vapor lamps,sodium lamps,and metal halide lamps. The capacitors are used for power factor compensation of transformers and magnetic ballasts in lamps with a frequency of 50Hz or 60Hz,which makes the power factor to achieve cosφ 0.9. The temperature
-
Product
Harmonic Clam Meter
-
TES Electrical Electronic Corp.
Analysis for 3p4W, 3P3W, 1P2W, 1P3W. True RMS VAlue. Active Pwer. Apparent and reactive pwer. Power FActor, Phase angle.
-
Product
Portable Wattmeter (Unity Power Factor)
-
Supreme Instrument Laboratories
The Principle of working is Electo-dynamometer type for Wattmeters. Portable dynamometer type single phase Single element Wattmeter housed in laminated wooden cabinet size 235 mm length x 200 mm width x 180 mm height, with detachable lid, black bakelite panel fitted with anti-parallax mirror scale, knife edge pointer, rubber footings, carrying handles, locking arrangements.
-
Product
Artificial Phantom Load with Power Factor
RC-50
-
The RC-50 Artificial Phantom Load has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges. Features: Artificial Load, Light Weight, 50 Amps, 50% Power Factor.
-
Product
Digital Power Meters
-
Switchboard meters with one, two or three digital readouts for measuring AC power parameters, including ACV, ACA, frequency, watts, vars, power factor, and phase angle.
-
Product
High Performance Programmable AC Power Source
61500 Series
-
Chroma 61500 Series have built in 16-bit measurement circuits and firmware utilities to measure the true RMS voltage, current, true power, apparent power, reactive power, power factor, current crest factor, and inrush current.
-
Product
AC / DC Digital Power Analyzer
4016(800Vp,20Arms/200Ap)
-
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
Product
Digital PFC Controllers with Power Metering
-
Are digital power factor correction (PFC) controllers that provide accurate input power metering capability and inrush current control for ac/dc systems.
-
Product
AC Power Source
61600 Series
-
Built-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable voltage,current limitComprehensive measurement capability,V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlOne-key recall for 9 different voltage and frequencyProgrammable slew rate setting for changing voltage and frequencyAnalog input for power amplifierOptional Analog programming interfaceOptional GPIB and RS-232 interface(Model 61601~61605)Full protection: OP,OC,OV and OT protectionEasy use graphic user interface: softpanel (option)Capable of delivering power output up tp 90KVA by implementing Master-Slave operation
-
Product
Electronic Ballast Tester
WT4000
-
• Measure parameter: 1) Input: Vrms, Lrms, W, PF, Hz, Phasic angle, total harmonic and 0-39 component of harmonic. 2) Output: Lamp voltage, Lamp current, Filament current, Guided cathodic current, Lamp power, crest factor and oscillatory frequency, single high frequency analysis. • Startup: Startup lamp voltage, lamp current, filament current, guided cathodic current curve and parameter, preheating time; • Simultaneously display on 8 windows for input and output parameters, convenient for comparison and analysis; • Test preheat energy, filament preheat time. And the parameters changes from 0 to 5s of filament voltage, filament current and filament power; • Up to 1MHz lrms test content to every EB; • Analysis symmetry of high Frequency curve of lout; • 12-bit high-speed A/D, sampling rate up to 10MHz, can easily analyse signal curve of output; • Finish an input and output testing at the same time within 1 minute; • Portable, can test, display, print without computer. Test report include data and curve, comply with international standard; • Communication port for PC, run under Windows98 or Windows2000, English Version available.
-
Product
3-Phase Programmable AC Source
61700
-
Chroma Systems Solutions, Inc.
Power: 1500VA, 3 (61701); 3000VA, 3 (61702); 4500VA, 3 (61703); 6000VA, 3 (61704); 12000VA, 3 (61705)Voltage: 0~150V/0~300VFrequency: 15~1.2KHzPhase angle: 0~360Built-in PFC, provides input power factor over 0.98Advanced PWM technology delivers high power density in a compact rack-mountable packageBuilt-in output isolation relaysAC+DC output modeProgrammable slew rate setting for changing voltage (optional function)Turn on, turn off phase angle controlUser-definable power-on statusPower line disturbance (PLD) simulation capability (optional function)Comprehensive measurement capability: V, Irms, Ipk, I inrush, P, PF, CF of current etc.Programmable r.m.s. current limitFull protection: OP, OC, OV and OT protectionGPIB and RS-232C interface (optional)Easy-use software for operation
-
Product
IGBT For PFC
-
IGBT product series for Power Factor Correction (PFC), UPS, solar power generation, and welding applications, recommended for 50 to 100 kHz frequencies, and not guaranteed against short circuit.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensationof power factor in low voltage instalations.
-
Product
Sigital Uninterruptible Power System
DT Series ET
-
The DT Series ET is a digital Uninterruptible Power System (UPS) which features Clary’s On-Line Double Conversion, Power Factor Corrected technology built for extreme temperature. Not only does the DT Series ET offer the highest reliability available on the market today, we consider it On-Line Double Conversion technology at its best.
-
Product
Bench Power Supply, Single, Adjustable, 2 Output, 1 V, 15 V, 60 A
72-7655
-
High current switch mode power supply with remote sensing and control.*Bright 3 digit dual LED displays*Simultaneous display of output voltage and current*Excellent load and line regulation*Low ripple and noise*Overload (constant current limiting), short circuit, over temperature and OVP protections*Variable speed thermal static control fan for cooling*Highly efficient active power factor corrector*Front panel banana jacks for loads up to 5A*Rear panel binding posts for loads up to 60A*12-month limited warranty *view Terms & Conditions for details
-
Product
Power Analyzers & Wattmeters
-
Measurements International Ltd.
Direct Replacement for 2010A Wattmeter in the AccuLoss® Loss Measurement Systems, Basic Power Accuracy < 0.005 %, 10 Current Ranges, 2 Voltage Ranges, Line-and-Line and Line-to-Ground Voltage Measurements, Full Power Factor Range, Complete Waveform Analysis, Total Harmonic Distortion Analysis, Phasor Analytical Representation.
-
Product
Capacitance & Tan Δ Power Factor Meter 2.5kV
CAPO 2.5
-
The measuring instrument CAPO 2.5 is a new Capacitance and tan δ / Power Factor Test Set developed by Raytech Engineers.
-
Product
Three Phase Meter Test Bench
-
Supreme Instrument Laboratories
Three phase meter test bench suitable for calibration & testing of AC Ammeters, Voltmeters, Single phase Energy Meters, Watt Meters, Power Factor Meters, Three Phase Two Wire & Three Phase Four Wire Energy Meters Trivector Meters, Maximum demand indicators, of active & reactive systems, Three phase 3 wire & 4 wire watt meters, Var Meters, Power Factor Meters etc.
-
Product
PWM Type AC Power Supply
LSP-5KVA
-
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Product
Automatic Battery
BATM
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations.
-
Product
Power Quality Analyzer
-
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
Product
Power, Patchcord, Receiver, 36", Mini Power, 16 AWG White
7-242956000-036
-
Power, Patchcord, Receiver, 36", Mini Power, 16 AWG White.
-
Product
PXI Power Supply 1 Channel 40W 48V 2A
PS48401
-
The PS48401 is a programmable DC power supply in a 2-slot PXI/cPCI form factor. It features a fully isolated output capable of delivering 0-48VDC / 2A / 40W. It offers a programmable current limit and the ability to measure the output voltage and current under software or trigger control.
-
Product
50W Power Supply, 35V, 1.4A or 60V, 0.8A
E3643A
-
Keysight basic DC power supplies offer essential features for a tight budget. The single & dual output, 30-100 W GPIB E3640 series provide small, compact size for bench and system use; low output ripple and noise; and built-in measurements and basic programmable features. The Keysight 48W, single output E3643A is a stable and reliable power supply for benchtop and basic automated test applications, and enables versatile solutions for tests that require moderate speed and precision with both GPIB and RS232.
-
Product
Three-Phase AC Power Source 320 Vrms, 18 KVA, 550 Hz
AC6918L
-
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
Product
Bench Power Supply, Switching DC, Adjustable, 1 Output, 0 V, 60 V, 0 A, 6 A
T3PS16006
-
Bench Power Supply, Switching DC, Adjustable, 1 Output, 0 V, 60 V, 0 A, 6 A.
-
Product
DC System Power Supply, 600 V, 1.3 A, 780 W
N5752A
-
The single output, 780 W N5752A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
Product
DC System Power Supply, 100V, 7.5A, 750W
N5749A
-
The single output, 750W N5749A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
Product
Power Supply Series
NGL200
-
Due to their high accuracy and fast load recovery time, the R&S®NGL200 power supply series is perfect for challenging applications. Their two-quadrant architecture allows them to function both as a source and a sink to simulate batteries and loads. Their short recovery times enable them to handle fast load changes that occur for example when mobile communications devices switch from sleep mode to transmit mode.
-
Product
EPM Series Dual-Channel Power Meter
N1914B
-
The N1914B EPM series dual-channel average power meter provides repeatable and reliable results for bench/rack and field applications.




























